The paper introduces CURRENT, a recurrent neural network that simultaneously performs spatial and temporal super‑resolution of 4D flow MRI velocity fields. Trained on synthetic data derived from computational fluid dynamics simulations embedded in real MRI backgrounds, CURRENT outperforms separate spatial or temporal SR models and improves relative pressure estimation. It also generalizes well to in‑vivo acquisitions, offering a unified solution for enhancing 4D flow MRI quality.
By Luuk Jacobs, Pietro Dirix, Sebastian Kozerke
FlowMoDL is an unrolled neural network designed for highly accelerated 4D flow MRI reconstruction, optimizing both anatomical magnitude and phase-derived velocity accuracy. It alternates a learned (3+1)D spatiotemporal denoiser with conjugate‑gradient data‑consistency updates, using a dual‑pathway conditioning scheme to handle acceleration factors from 10× to 50×. Trained with a deep‑supervision composite loss that penalizes velocity magnitude and angular errors, FlowMoDL outperforms classical and deep‑learning baselines on the multi‑center CMRx4DFlow dataset, achieving superior gradient‑step efficiency and robust convergence across all acceleration factors.
By Tristan Gottwald, Michelle Bruch, Mubashir-Ul Hassan, Fatma Alickovic, Milan Kloiber, Daniel Tenbrinck, Torsten Panholzer, Melanie Schaller, Jana Hutter
arXiv:2608. 13629v1 Announce Type: cross Abstract: Clinically actionable, patient-specific hemodynamic assessment, specifically wall shear stress, vortex structure and pressure distributions, is critical for determining risky or unfavorable evolution in Abdominal Aortic Aneurysms (AAA).
By Oscar L. Cruz-Gonzalez, Val\'erie Deplano, Badih Ghattas
arXiv:2606. 06313v1 Announce Type: cross Abstract: Wall shear stress (WSS) governs near-wall transport dynamics and is a key hemodynamic indicator in cardiovascular flows, yet remains difficult to infer accurately due to the need for precise computation of near-wall velocity gradients.
By Mahmoud Elhadidy, Siva Viknesh, Roshan M. D'Souza, Amirhossein Arzani
arXiv:2608. 03430v1 Announce Type: cross Abstract: Four-dimensional cone beam CT (4D CBCT) is important for image-guided radiation therapy of thoracic cancers, but its use is limited by long scan times, causing high patient dose and motion/sparse-sampling artifacts.
By Ivo Herzig, Pascal Paysan, Daniel Barco, Marc Andr\'e Stadelmann, Frank-Peter Schilling, Igor Peterlik, Michal Walczak, Lijin Aryananda, Woo Sang Ahn, Rudolf Marcel F\"uchslin, Lukas Lichtensteiger
The paper presents a deep learning super‑resolution framework for 4D flow MRI of carotid arteries, using convolutional block attention modules to focus on clinically relevant spatial features and reduce noise. Trained on 120 patients with 240 stenosed carotid arteries, the model leverages patient‑specific CFD simulations as high‑resolution ground truth. Results show a significant reduction in RMSE and improved reconstruction of complex flow patterns compared to a baseline without attention.
By Ali Mokhtari, Dominik Obrist
The paper introduces a physics-informed deep learning framework that reconstructs 3D coronary geometry from dual-view angiography and predicts velocity and pressure fields using a decoupled network with embedded physical priors. Across 32 patients and four flow conditions, the model achieved a trans‑stenotic pressure‑drop error of 2.02% and velocity/pressure relative‑L2 errors of 0.054 and 0.023, respectively, while matching hospital‑measured FFR with 93.8% diagnostic accuracy. The pipeline completes the full angiography‑to‑hemodynamics conversion in about 20 minutes per patient and supports sparse‑data assimilation for revascularization planning.
By Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye, Qiang Luo, Mao Chen, Wenqi Hu
arXiv:2611.27917v1 Announce Type: cross
Abstract: Cardiovascular imaging offers several ways to measure blood flow, but each provides an incomplete, resolution-limited, or noisy view of the underlyin...
By Fabio Guglietta, Tianyi Li, Francesco Viola, Luca Biferale
arXiv:2606. 26764v1 Announce Type: cross Abstract: Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions.
By Yiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang, Lingxiao Zhao, Xin Gao
The study explores task‑aware projection selection for predicting hemodynamics from sparse‑view CT angiography. Using synthetic CTA data and a Fourier neural operator, the authors compare fixed sampling schemes with three optimal selection methods—Gumbel‑Softmax, Soft top‑K, and an agentic AI selector—finding that the agentic and Soft top‑K approaches yield the lowest errors for spatially resolved wall shear stress, especially under extreme sparsity. The analysis shows that task‑optimal masks differ markedly from those optimal for image reconstruction, highlighting a new direction for designing sparse acquisitions around downstream physical quantities.
By Mahmoud Elhadidy, Roshan M. D'Souza, Amirhossein Arzani
arXiv:2610.16645v1 Announce Type: cross
Abstract: Recovering divergence-free velocity fields from sparse and corrupted observations requires reconciling physical consistency, expressive representatio...
By Ramzi Idoughi, Radouan Boukharfane, Peter Wonka
Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions. To address this, we propose a 4D controllable generative framework for anatomically consistent data augmentation.