arXiv AI

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

The paper introduces a physics-informed deep learning framework that reconstructs 3D coronary geometry from dual-view angiography and predicts velocity and pressure fields using a decoupled network with embedded physical priors. Across 32 patients and four flow conditions, the model achieved a trans‑stenotic pressure‑drop error of 2.02% and velocity/pressure relative‑L2 errors of 0.054 and 0.023, respectively, while matching hospital‑measured FFR with 93.8% diagnostic accuracy. The pipeline completes the full angiography‑to‑hemodynamics conversion in about 20 minutes per patient and supports sparse‑data assimilation for revascularization planning.

arXiv Machine Learning
Jul 27

CARDIAG: A Dense Segment Classification Benchmark of Deep Learning Architectures for Coronary Angiography

arXiv:2607. 22139v1 Announce Type: cross Abstract: Accurate pixel-level classification of coronary angiograms is critical for cardiovascular disease assessment, yet the field lacks standardized evaluation protocols.

By Dominik Bernard Lau, Hubert Malinowski, Jerzy Szyjut, Adam Brzeski, Tomasz Dziubich, Rados{\l}aw Targo\'nski, Tomasz Figatowski, Natalia Zieli\'nska
arXiv Machine Learning
Aug 17

Learning Unsteady Aneurysm Hemodynamics with Physics-Informed DeepONets

arXiv:2608. 13629v1 Announce Type: cross Abstract: Clinically actionable, patient-specific hemodynamic assessment, specifically wall shear stress, vortex structure and pressure distributions, is critical for determining risky or unfavorable evolution in Abdominal Aortic Aneurysms (AAA).

By Oscar L. Cruz-Gonzalez, Val\'erie Deplano, Badih Ghattas
arXiv AI
Sep 7

Attention-guided super-resolution of 4D flow MRI in carotid arteries

The paper presents a deep learning super‑resolution framework for 4D flow MRI of carotid arteries, using convolutional block attention modules to focus on clinically relevant spatial features and reduce noise. Trained on 120 patients with 240 stenosed carotid arteries, the model leverages patient‑specific CFD simulations as high‑resolution ground truth. Results show a significant reduction in RMSE and improved reconstruction of complex flow patterns compared to a baseline without attention.

By Ali Mokhtari, Dominik Obrist
arXiv AI
1d ago

A Multi-Center Dataset and Benchmark for SYNTAX Segmentation of Coronary Angiograms

The paper introduces CARDIAG, a multi‑center benchmark dataset for fine‑grained SYNTAX segmentation of coronary angiograms, featuring highly imbalanced multi‑class labels, catheter and stenosis masks, expert uncertainty maps, temporal frames, and spatial metadata. The authors conduct an extensive architectural sweep of 24 models—including CNNs, Vision Transformers, and State‑Space Models—using advanced metrics such as clDice, vessel diameter error, and uncertainty error‑detection. Their findings show that large‑kernel CNNs (ConvNeXt V2 with DeepLabV3+) outperform recent ViTs and SSMs, achieving a Dice score of 0.456, which improves to 0.479 with model ensembling, while also exploring out‑of‑distribution generalization through leave‑one‑center‑out cross‑validation.

By Dominik Bernard Lau, Jerzy Szyjut, Hubert Malinowski, Adam Brzeski, Tomasz Dziubich, Natalia Zieli\'nska, Tomasz Figatowski, Rados{\l}aw Targo\'nski
arXiv Machine Learning
Jun 5

Wall Shear Stress Reconstruction from Concentration: Differentiable Physics and Physics-Informed Neural Networks

arXiv:2606. 06313v1 Announce Type: cross Abstract: Wall shear stress (WSS) governs near-wall transport dynamics and is a key hemodynamic indicator in cardiovascular flows, yet remains difficult to infer accurately due to the need for precise computation of near-wall velocity gradients.

By Mahmoud Elhadidy, Siva Viknesh, Roshan M. D'Souza, Amirhossein Arzani
arXiv Computer Vision
Oct 8

PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic Views

PPCAR-Net is a neural network that reconstructs 3‑D coronary artery centrelines and radii from a sparse set of X‑ray angiographic views. It predicts a branch‑structured centreline-and‑radius representation directly, avoiding explicit point matching or triangulation. The method refines geometry and radius estimates using projection‑guided refiners and achieves real‑time performance with strong centreline accuracy, especially for the right coronary artery.

By Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo
arXiv Machine Learning
Sep 21

Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation

The paper presents a Deep Operator Network that reconstructs full‑field 4D mitral regurgitation hemodynamics from sparse planar velocity data and boundary pressure traces. The network is pretrained on a URANS database of eleven orifice phantoms and then fine‑tuned on new cases, achieving rapid predictions in minutes. While the adaptation improves flow topology in the observed plane, reconstruction error increases sharply with distance from that plane, limiting physical consistency in the surrounding volume.

By Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh
arXiv Computer Vision
Oct 21

Vascular anatomy-aware self-supervised pre-training for X-ray angiogram analysis

The paper introduces VasoMIM, a vascular anatomy‑aware masked image modeling framework for X‑ray angiogram analysis, which uses an anatomy‑guided masking strategy and an anatomical consistency loss to learn robust vascular representations. It also presents XA‑170K, the largest pre‑training dataset for X‑ray angiograms. Experiments on six datasets and four downstream tasks show that VasoMIM outperforms existing methods and achieves state‑of‑the‑art performance.

By De-Xing Huang, Chaohui Yu, Xiao-Hu Zhou, Tian-Yu Xiang, Qin-Yi Zhang, Mei-Jiang Gui, Rui-Ze Ma, Chen-Yu Wang, Nu-Fang Xiao, Fan Wang, Zeng-Guang Hou
arXiv Computer Vision
Oct 27

Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI

arXiv:2610.33124v1 Announce Type: cross Abstract: 4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resoluti...

By Oliver Welin Odeback, Nerea Gonz\'alez-Aranceta, Sebasti\'an Jofre, Javier Bisbal, Edward Ferdian, Alistair A. Young, Pia Callmer, Sameer A. Ansari, Mia Bonini, David Nordsletten, Patrick Winter, Susanne Schnell, Tobias Granberg, Alexander Fyrdahl, David Marlevi
Hugging Face Trending Papers
Aug 19

X-LMC: Cross-View Spatiotemporal Collateral Circulation Scoring from DSA

X‑LMC is a spatiotemporal deep‑learning framework that automatically scores leptomeningeal collateral (LMC) status from time‑resolved biplane digital subtraction angiography (DSA). It uses a DINOv2 backbone to encode spatial frames, a token‑level cross‑view attention module to fuse orthogonal projections, and a recurrent network to model contrast bolus dynamics. On a multicenter dataset of 134 M1‑segment occlusion patients, X‑LMC achieved a Quadratic Weighted Kappa of 0.398 and a macro‑F1 of 0.711, outperforming static and other spatiotemporal baselines and matching clinical inter‑rater agreement.