arXiv Computer Vision By Luuk Jacobs, Pietro Dirix, Sebastian Kozerke

CURRENT: A Recurrent Neural Network for Concurrent Spatial and Temporal Super-Resolution of 4D Flow MRI

Read the original on arXiv Computer Vision →

The paper introduces CURRENT, a recurrent neural network that simultaneously performs spatial and temporal super‑resolution of 4D flow MRI velocity fields. Trained on synthetic data derived from computational fluid dynamics simulations embedded in real MRI backgrounds, CURRENT outperforms separate spatial or temporal SR models and improves relative pressure estimation. It also generalizes well to in‑vivo acquisitions, offering a unified solution for enhancing 4D flow MRI quality.

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at arXiv Computer Vision.

arXiv AI
Sep 7

Attention-guided super-resolution of 4D flow MRI in carotid arteries

The paper presents a deep learning super‑resolution framework for 4D flow MRI of carotid arteries, using convolutional block attention modules to focus on clinically relevant spatial features and reduce noise. Trained on 120 patients with 240 stenosed carotid arteries, the model leverages patient‑specific CFD simulations as high‑resolution ground truth. Results show a significant reduction in RMSE and improved reconstruction of complex flow patterns compared to a baseline without attention.

By Ali Mokhtari, Dominik Obrist
arXiv Machine Learning
Aug 27

FlowMoDL: Model-Based Deep Learning with Conjugate-Gradient Data Consistency for Highly Accelerated 4D Flow MRI Reconstruction

FlowMoDL is an unrolled neural network designed for highly accelerated 4D flow MRI reconstruction, optimizing both anatomical magnitude and phase-derived velocity accuracy. It alternates a learned (3+1)D spatiotemporal denoiser with conjugate‑gradient data‑consistency updates, using a dual‑pathway conditioning scheme to handle acceleration factors from 10× to 50×. Trained with a deep‑supervision composite loss that penalizes velocity magnitude and angular errors, FlowMoDL outperforms classical and deep‑learning baselines on the multi‑center CMRx4DFlow dataset, achieving superior gradient‑step efficiency and robust convergence across all acceleration factors.

By Tristan Gottwald, Michelle Bruch, Mubashir-Ul Hassan, Fatma Alickovic, Milan Kloiber, Daniel Tenbrinck, Torsten Panholzer, Melanie Schaller, Jana Hutter
arXiv Computer Vision
Oct 27

Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI

arXiv:2610.33124v1 Announce Type: cross Abstract: 4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resoluti...

By Oliver Welin Odeback, Nerea Gonz\'alez-Aranceta, Sebasti\'an Jofre, Javier Bisbal, Edward Ferdian, Alistair A. Young, Pia Callmer, Sameer A. Ansari, Mia Bonini, David Nordsletten, Patrick Winter, Susanne Schnell, Tobias Granberg, Alexander Fyrdahl, David Marlevi
arXiv Machine Learning
Sep 21

Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation

The paper presents a Deep Operator Network that reconstructs full‑field 4D mitral regurgitation hemodynamics from sparse planar velocity data and boundary pressure traces. The network is pretrained on a URANS database of eleven orifice phantoms and then fine‑tuned on new cases, achieving rapid predictions in minutes. While the adaptation improves flow topology in the observed plane, reconstruction error increases sharply with distance from that plane, limiting physical consistency in the surrounding volume.

By Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh
arXiv Computer Vision
Oct 27

Toward Clinical Translation of Deep Learning-Based Intracranial Super-Resolution 4D Flow MRI Using Multi-Cohort Transfer Learning

arXiv:2610.35396v1 Announce Type: new Abstract: We evaluated synthetic pretraining and multi-cohort transfer learning for deep learning-based super-resolution of intracranial 4D Flow MRI across heter...

By Oliver Welin Odeback, Susanne Schnell, Patrick Winter, Johan Lundberg, Fredrik Piehl, Tobias Granberg, Alexander Fyrdahl, David Marlevi
arXiv Computer Vision
Sep 7

Segmentation of the aorta in 4D flow MRI using 4D convolutional kernels and learning from sparse annotations

The study presents a fully automated 4D U‑Net that segments the ascending aorta, arch, and proximal descending aorta in 4D flow MRI using a hybrid 4D convolutional kernel and sparse 4D labels derived from 2D expert contours and centerlines. Trained on 268 scans from eight centers, the model achieved high Dice scores (0.927 internal, 0.911 external) and excellent agreement with expert measurements of peak velocity, net flow, wall shear stress, and diameters (ICC ≥0.954 internal, ≥0.980 external). Compared to frame‑wise 3D networks and semi‑automatic methods, the 4D U‑Net outperformed in diastole and generalised well to independent post‑contrast data.

By Hinrich Rahlfs, Julio Garcia, Chiara Manini, Markus H\"ullebrand, Sebastian Schmitter, Sarah Nordmeyer, Titus K\"uhne, Heiko Stern, Christian Meierhofer, Andreas Harloff, Sebastian Kelle, Alexander Lenz, Peter Bannas, Jeanette Schulz-Menger, Ralf F Trauzeddel, Anja Hennemuth