arXiv:2607. 03299v1 Announce Type: cross Abstract: Real-time cardiac cine MRI enables visualization of the beating heart during free breathing, but severe undersampling and motion make reconstruction highly challenging.
By Florian F\"urnrohr, Reinhard Heckel
The paper introduces a high‑resolution Rectified Flow Matching model trained on 256×256 chest CT images to serve as a generative prior for CT reconstruction. A two‑stage training strategy—initial strong anatomically informed augmentation followed by fine‑tuning—helps mitigate overfitting and improve structural fidelity. When evaluated on various CT inverse problems, Flow Matching‑based reconstruction methods outperform diffusion‑based algorithms in PSNR, SSIM, and perceptual quality while requiring fewer sampling steps.
By Davide Evangelista
arXiv:2603. 00205v2 Announce Type: replace-cross Abstract: Generative models, particularly Diffusion Models (DM), have shown strong potential for Computed Tomography (CT) reconstruction serving as expressive priors for solving ill-posed inverse problems.
By Jiayang Shi, Lincen Yang, Zhong Li, Tristan van Leeuwen, Daniel M. Pelt, K. Joost Batenburg
Vessel2Brain introduces an edge‑aware, multi‑scale flow matching framework that generates realistic 3D brain MRI volumes conditioned only on vascular label maps. By treating vessel‑guided synthesis as a conditional continuous flow, the method achieves stable training and preserves structural correspondence. Experiments on two public datasets show that Vessel2Brain outperforms existing generative models in reconstruction accuracy, structural consistency, and realism.
By Zhi Chen, Tianyang Zhang, Theodoros N. Arvanitis, Le Zhang
The paper presents a Deep Operator Network that reconstructs full‑field 4D mitral regurgitation hemodynamics from sparse planar velocity data and boundary pressure traces. The network is pretrained on a URANS database of eleven orifice phantoms and then fine‑tuned on new cases, achieving rapid predictions in minutes. While the adaptation improves flow topology in the observed plane, reconstruction error increases sharply with distance from that plane, limiting physical consistency in the surrounding volume.
By Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh
LatentFM is a flow-based generative model that operates in latent space for medical image segmentation. It uses two variational autoencoders to encode images and masks, then estimates a conditional velocity field to guide flow, producing diverse segmentation outputs with pixel-wise variance that captures uncertainty. Experiments on ISIC‑2018 and CVC‑Clinic datasets show that LatentFM achieves superior segmentation accuracy while remaining efficient in latent space.
By Ngoc Huynh Trinh, Hoang Anh Nguyen Kim, Hai Toan Nguyen, Quoc Long Tran
arXiv:2606. 26764v1 Announce Type: cross Abstract: Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions.
By Yiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang, Lingxiao Zhao, Xin Gao
arXiv:2610.08983v1 Announce Type: new
Abstract: Generative inpainting of brain MRI volumes is essential for synthesizing healthy tissue in pathological regions, improving the accuracy and reliability...
By Arnela Hadzic, Franz Thaler, Simon Johannes Joham, Martin Urschler
Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions. To address this, we propose a 4D controllable generative framework for anatomically consistent data augmentation.
NullFlow is a new framework for one-step generative image reconstruction that confines the generative flow to a measurement‑consistent subspace, eliminating the need for separate data‑fidelity corrections. By learning the flow’s average velocity, NullFlow can sample in a single network evaluation, avoiding the step‑by‑step integration used by traditional flow matching methods. Experiments on image inpainting and accelerated MRI show that NullFlow matches state‑of‑the‑art diffusion solvers while reducing inference from hundreds of evaluations to just one.
By Xiao Shi, Edward P. Chandler, Chicago Y. Park, Shirin Shoushtari, Ulugbek S. Kamilov
arXiv:2608. 09460v1 Announce Type: new Abstract: Cardiac digital twin research is moving from subject-specific anatomical replicas toward virtual cohorts that represent clinically relevant population subgroups.
By Konstantinos Kevopoulos, Beatrice Moscoloni, Benjamin Alheit, Cameron Beeche, Julio A. Chirinos, Alexander Heinlein, Mathias Peirlinck
CardioTrace is a motion‑aware cine synthesis framework that generates complete cardiac cine MRI sequences from limited input. It couples a pixel‑translation branch, a flow‑field branch for deformation estimation, and a segmentation branch to supervise key cardiac structures, while a cross‑branch consistency objective ensures realistic motion dynamics. The model supports prompt‑style conditioning for robustness across multi‑center data and outperforms GAN and diffusion baselines in perceptual quality, temporal coherence, and ventricular morphology preservation.
By Zhi Chen, Le Zhang