Augmentation of cardiovascular flow measurements with generative diffusion models
Read the original on arXiv Computer Vision →The Flow has not summarised this story yet — read it at arXiv Computer Vision.
The Flow has not summarised this story yet — read it at arXiv Computer Vision.
arXiv:2607. 03299v1 Announce Type: cross Abstract: Real-time cardiac cine MRI enables visualization of the beating heart during free breathing, but severe undersampling and motion make reconstruction highly challenging.
The paper introduces a high‑resolution Rectified Flow Matching model trained on 256×256 chest CT images to serve as a generative prior for CT reconstruction. A two‑stage training strategy—initial strong anatomically informed augmentation followed by fine‑tuning—helps mitigate overfitting and improve structural fidelity. When evaluated on various CT inverse problems, Flow Matching‑based reconstruction methods outperform diffusion‑based algorithms in PSNR, SSIM, and perceptual quality while requiring fewer sampling steps.
arXiv:2603. 00205v2 Announce Type: replace-cross Abstract: Generative models, particularly Diffusion Models (DM), have shown strong potential for Computed Tomography (CT) reconstruction serving as expressive priors for solving ill-posed inverse problems.
Vessel2Brain introduces an edge‑aware, multi‑scale flow matching framework that generates realistic 3D brain MRI volumes conditioned only on vascular label maps. By treating vessel‑guided synthesis as a conditional continuous flow, the method achieves stable training and preserves structural correspondence. Experiments on two public datasets show that Vessel2Brain outperforms existing generative models in reconstruction accuracy, structural consistency, and realism.
The paper presents a Deep Operator Network that reconstructs full‑field 4D mitral regurgitation hemodynamics from sparse planar velocity data and boundary pressure traces. The network is pretrained on a URANS database of eleven orifice phantoms and then fine‑tuned on new cases, achieving rapid predictions in minutes. While the adaptation improves flow topology in the observed plane, reconstruction error increases sharply with distance from that plane, limiting physical consistency in the surrounding volume.
LatentFM is a flow-based generative model that operates in latent space for medical image segmentation. It uses two variational autoencoders to encode images and masks, then estimates a conditional velocity field to guide flow, producing diverse segmentation outputs with pixel-wise variance that captures uncertainty. Experiments on ISIC‑2018 and CVC‑Clinic datasets show that LatentFM achieves superior segmentation accuracy while remaining efficient in latent space.