arXiv AI

Attention-guided super-resolution of 4D flow MRI in carotid arteries

The paper presents a deep learning super‑resolution framework for 4D flow MRI of carotid arteries, using convolutional block attention modules to focus on clinically relevant spatial features and reduce noise. Trained on 120 patients with 240 stenosed carotid arteries, the model leverages patient‑specific CFD simulations as high‑resolution ground truth. Results show a significant reduction in RMSE and improved reconstruction of complex flow patterns compared to a baseline without attention.

arXiv Computer Vision
Oct 27

Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI

arXiv:2610.33124v1 Announce Type: cross Abstract: 4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resoluti...

By Oliver Welin Odeback, Nerea Gonz\'alez-Aranceta, Sebasti\'an Jofre, Javier Bisbal, Edward Ferdian, Alistair A. Young, Pia Callmer, Sameer A. Ansari, Mia Bonini, David Nordsletten, Patrick Winter, Susanne Schnell, Tobias Granberg, Alexander Fyrdahl, David Marlevi
arXiv Machine Learning
Aug 27

FlowMoDL: Model-Based Deep Learning with Conjugate-Gradient Data Consistency for Highly Accelerated 4D Flow MRI Reconstruction

FlowMoDL is an unrolled neural network designed for highly accelerated 4D flow MRI reconstruction, optimizing both anatomical magnitude and phase-derived velocity accuracy. It alternates a learned (3+1)D spatiotemporal denoiser with conjugate‑gradient data‑consistency updates, using a dual‑pathway conditioning scheme to handle acceleration factors from 10× to 50×. Trained with a deep‑supervision composite loss that penalizes velocity magnitude and angular errors, FlowMoDL outperforms classical and deep‑learning baselines on the multi‑center CMRx4DFlow dataset, achieving superior gradient‑step efficiency and robust convergence across all acceleration factors.

By Tristan Gottwald, Michelle Bruch, Mubashir-Ul Hassan, Fatma Alickovic, Milan Kloiber, Daniel Tenbrinck, Torsten Panholzer, Melanie Schaller, Jana Hutter
arXiv AI
Sep 18

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

The paper introduces a physics-informed deep learning framework that reconstructs 3D coronary geometry from dual-view angiography and predicts velocity and pressure fields using a decoupled network with embedded physical priors. Across 32 patients and four flow conditions, the model achieved a trans‑stenotic pressure‑drop error of 2.02% and velocity/pressure relative‑L2 errors of 0.054 and 0.023, respectively, while matching hospital‑measured FFR with 93.8% diagnostic accuracy. The pipeline completes the full angiography‑to‑hemodynamics conversion in about 20 minutes per patient and supports sparse‑data assimilation for revascularization planning.

By Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye, Qiang Luo, Mao Chen, Wenqi Hu
arXiv Computer Vision
Oct 27

Toward Clinical Translation of Deep Learning-Based Intracranial Super-Resolution 4D Flow MRI Using Multi-Cohort Transfer Learning

arXiv:2610.35396v1 Announce Type: new Abstract: We evaluated synthetic pretraining and multi-cohort transfer learning for deep learning-based super-resolution of intracranial 4D Flow MRI across heter...

By Oliver Welin Odeback, Susanne Schnell, Patrick Winter, Johan Lundberg, Fredrik Piehl, Tobias Granberg, Alexander Fyrdahl, David Marlevi
arXiv Machine Learning
Sep 21

Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation

The paper presents a Deep Operator Network that reconstructs full‑field 4D mitral regurgitation hemodynamics from sparse planar velocity data and boundary pressure traces. The network is pretrained on a URANS database of eleven orifice phantoms and then fine‑tuned on new cases, achieving rapid predictions in minutes. While the adaptation improves flow topology in the observed plane, reconstruction error increases sharply with distance from that plane, limiting physical consistency in the surrounding volume.

By Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh
arXiv Machine Learning
Jun 5

Wall Shear Stress Reconstruction from Concentration: Differentiable Physics and Physics-Informed Neural Networks

arXiv:2606. 06313v1 Announce Type: cross Abstract: Wall shear stress (WSS) governs near-wall transport dynamics and is a key hemodynamic indicator in cardiovascular flows, yet remains difficult to infer accurately due to the need for precise computation of near-wall velocity gradients.

By Mahmoud Elhadidy, Siva Viknesh, Roshan M. D'Souza, Amirhossein Arzani
arXiv Machine Learning
Sep 3

Enhancing brain age estimation with structural MRI and synthesized cerebral blood volume maps

The study presents a multimodal BrainAGE framework that fuses structural T1-weighted MRI with DeepCBV maps—vascular information synthesized from non‑contrast MRI—to estimate brain age more accurately. Using two separate 3D convolutional neural networks, the combined model achieved a mean absolute error of 3.95 years on cognitively normal controls, outperforming single‑modality models. Saliency analyses showed MRI highlighted white matter and cortical atrophy, while DeepCBV emphasized vascular‑rich regions, and the integrated approach revealed stronger differentiation between stable and progressive MCI, indicating sensitivity to early vascular changes.

By Jordan Jomsky, Zongyu Li, Kay C. Igwe, Yiren Zhang, Max Lashley, Tal Nuriel, Andrew Laine, Scott A. Small, Jia Guo, for the Frontotemporal Lobar Degeneration Neuroimaging Initiative, for the Alzheimer's Disease Neuroimaging Initiative
Hugging Face Trending Papers
Aug 19

X-LMC: Cross-View Spatiotemporal Collateral Circulation Scoring from DSA

X‑LMC is a spatiotemporal deep‑learning framework that automatically scores leptomeningeal collateral (LMC) status from time‑resolved biplane digital subtraction angiography (DSA). It uses a DINOv2 backbone to encode spatial frames, a token‑level cross‑view attention module to fuse orthogonal projections, and a recurrent network to model contrast bolus dynamics. On a multicenter dataset of 134 M1‑segment occlusion patients, X‑LMC achieved a Quadratic Weighted Kappa of 0.398 and a macro‑F1 of 0.711, outperforming static and other spatiotemporal baselines and matching clinical inter‑rater agreement.