The paper introduces CM-RED, a fast MRI reconstruction method that combines a pretrained consistency model with the regularization by denoising framework. By integrating controlled noise injection into accelerated proximal gradient updates, CM-RED achieves high‑quality reconstructions on fastMRI knee and brain datasets with only four network function evaluations. It consistently outperforms existing diffusion‑ and consistency‑based approaches in quantitative metrics, visual fidelity, and robustness to hyperparameter changes.
By Merve G\"ulle, Junno Yun, Ya\c{s}ar Utku Al\c{c}alar, Mehmet Ak\c{c}akaya
The paper presents a deep learning super‑resolution framework for 4D flow MRI of carotid arteries, using convolutional block attention modules to focus on clinically relevant spatial features and reduce noise. Trained on 120 patients with 240 stenosed carotid arteries, the model leverages patient‑specific CFD simulations as high‑resolution ground truth. Results show a significant reduction in RMSE and improved reconstruction of complex flow patterns compared to a baseline without attention.
By Ali Mokhtari, Dominik Obrist
FLAT: FLow-Aligned Training of Unrolled Networks for MRI Reconstruction proposes a new training method for unrolled neural networks used in MRI reconstruction. By interpreting unrolled networks as discretizations of conditional probability flows, the authors derive cascade parameters from Flow Matching and align intermediate reconstructions with the ideal Flow Matching trajectory. Experiments on three MRI datasets demonstrate that FLAT stabilizes the reconstruction trajectory across sub-networks and improves the final reconstruction quality.
By Kehan Qi, Saumya Gupta, Xiaoling Hu, Qingqiao Hu, Weimin Lyu, Yicun Wang, Chao Chen
arXiv:2609.00960v1 Announce Type: new
Abstract: Magnetic resonance images of the same subject look markedly different across field strengths, which complicates the comparison and pooling of data acro...
By Baris Imre, Aram Salehi, Levente Baljer, Andrew Webb, Marius Staring, Efe Ilicak
arXiv:2606. 00146v1 Announce Type: cross Abstract: Motion artifacts in magnetic resonance imaging (MRI) degrade diagnostic reliability.
By Honglin Xiong, Yuxian Tang, Feng Li, Yulin Wang, Lei Xiang, Dinggang Shen, Qian Wang
arXiv:2607. 12171v1 Announce Type: cross Abstract: In rectified-flow-based generative models, the neural network can be trained to predict two different targets, such as the instantaneous velocity or the data endpoint, to perform denoising.
By Xu Han, Jiajing Hu, Li-Ping Liu
Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions. To address this, we propose a 4D controllable generative framework for anatomically consistent data augmentation.
arXiv:2610.08109v1 Announce Type: new
Abstract: Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while prese...
By Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor
arXiv:2603. 03710v3 Announce Type: replace-cross Abstract: Zero-shot MRI reconstruction relies on generative priors, but single-modality unconditional priors produce hallucinations under severe ill-posedness.
By Seunghoi Kim, Chen Jin, Henry F. J. Tregidgo, Matteo Figini, Daniel C. Alexander
arXiv:2609.38644v1 Announce Type: cross
Abstract: 4D flow MRI measures time-resolved, three-directional blood velocity but requires long acquisition times, and its diagnostic signal is carried by the...
By Mengyuan Xue, Bochun Mei
arXiv:2606. 26764v1 Announce Type: cross Abstract: Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions.
By Yiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang, Lingxiao Zhao, Xin Gao
The paper presents a Deep Operator Network that reconstructs full‑field 4D mitral regurgitation hemodynamics from sparse planar velocity data and boundary pressure traces. The network is pretrained on a URANS database of eleven orifice phantoms and then fine‑tuned on new cases, achieving rapid predictions in minutes. While the adaptation improves flow topology in the observed plane, reconstruction error increases sharply with distance from that plane, limiting physical consistency in the surrounding volume.
By Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh