The paper introduces a physics-informed deep learning framework that reconstructs 3D coronary geometry from dual-view angiography and predicts velocity and pressure fields using a decoupled network with embedded physical priors. Across 32 patients and four flow conditions, the model achieved a trans‑stenotic pressure‑drop error of 2.02% and velocity/pressure relative‑L2 errors of 0.054 and 0.023, respectively, while matching hospital‑measured FFR with 93.8% diagnostic accuracy. The pipeline completes the full angiography‑to‑hemodynamics conversion in about 20 minutes per patient and supports sparse‑data assimilation for revascularization planning.
By Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye, Qiang Luo, Mao Chen, Wenqi Hu
arXiv:2608. 13629v1 Announce Type: cross Abstract: Clinically actionable, patient-specific hemodynamic assessment, specifically wall shear stress, vortex structure and pressure distributions, is critical for determining risky or unfavorable evolution in Abdominal Aortic Aneurysms (AAA).
By Oscar L. Cruz-Gonzalez, Val\'erie Deplano, Badih Ghattas
arXiv:2509. 15900v2 Announce Type: replace-cross Abstract: This work aims to predict blood flow with non-Newtonian viscosity in stenosed arteries using convolutional neural network (CNN) surrogate models.
By Simon Klaes, Axel Klawonn, Natalie Kubicki, Martin Lanser, Kengo Nakajima, Takashi Shimokawabe, Janine Weber
The paper presents a Deep Operator Network that reconstructs full‑field 4D mitral regurgitation hemodynamics from sparse planar velocity data and boundary pressure traces. The network is pretrained on a URANS database of eleven orifice phantoms and then fine‑tuned on new cases, achieving rapid predictions in minutes. While the adaptation improves flow topology in the observed plane, reconstruction error increases sharply with distance from that plane, limiting physical consistency in the surrounding volume.
By Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh
The paper presents a deep learning super‑resolution framework for 4D flow MRI of carotid arteries, using convolutional block attention modules to focus on clinically relevant spatial features and reduce noise. Trained on 120 patients with 240 stenosed carotid arteries, the model leverages patient‑specific CFD simulations as high‑resolution ground truth. Results show a significant reduction in RMSE and improved reconstruction of complex flow patterns compared to a baseline without attention.
By Ali Mokhtari, Dominik Obrist
arXiv:2609.15104v1 Announce Type: cross
Abstract: We present the development and application of a three-dimensional Physics-Informed Neural Network (PINN) framework for the investigation of haemodyna...
By Adri\'an Robles Arques, Mart\'in Ruiz Fernandez, Javier Sanchis, Miguel A. Teruel, Juan Trujillo