arXiv:2607. 28759v1 Announce Type: cross Abstract: In X-ray CT, metallic objects cause beam hardening, photon starvation, and scattering, leading to projection inconsistency, streaks, dark bands, and structural distortions that compromise clinical diagnosis and quantitative analysis.
By Heran Wang, Jianing Sun, Xu Jiang, Genwei Ma, Xing Zhao, Jigang Duan
arXiv:2607. 12175v1 Announce Type: cross Abstract: X-ray tomography enables nondestructive characterization of material microstructures, while advances in micro-CT imaging have accelerated volumetric data acquisition and reconstruction.
By Pradyumna Elavarthi, Arun J. Bhattacharjee, Harrison Lisabeth, Anca Ralescu, Petrus H. Zwart, Dilworth Parkinson, Elizabeth G. Clark
arXiv:2607. 14287v1 Announce Type: cross Abstract: Defect segmentation in additive manufacturing (AM) X-ray computed tomography (XCT) images remains challenging due to severe class imbalance and large distribution shifts across scan conditions.
By Md Mahedi Hasan, Md Mushfiqur Rahaman, Alan Pachkovskiy, Imtiaz Ahmed, Jeremy Dawson, Srinjoy Das
Generating a 3D dental volume from a single panoramic radiograph (PXR) could provide a low-radiation alternative to Cone-Beam Computed Tomography (CBCT), but the problem is highly underdetermined: panoramic acquisition integrates 3D attenuation along curved X-ray paths into a 2D image, leaving depth-resolved anatomy unobserved. Existing implicit and generative approaches often produce oversmoothed geometry or anatomically inconsistent hallucinations, lacking geometry-driven supervision and relying on smooth representations unable to precisely localize sharp anatomical boundaries.
Sparse-view computed tomography is a severely ill-posed inverse problem, where recent 3D Gaussian Splatting methods offer an efficient explicit representation for tomographic reconstruction. However, we find that projection-domain optimization can be misleading in this setting: the rendered projections may continue to improve while the reconstructed volume deteriorates.
arXiv:2608. 17255v1 Announce Type: cross Abstract: X-ray imaging can be approximately modeled as the projection of an underlying volumetric attenuation field, with each measurement recording the accumulated attenuation along a corresponding ray path.
By Yifei Wu, Yicheng Wu, Qiang Ma, Qi Chen, Renyang Gu, Xinyu Liu, Yongsheng Pan, Yong Xia
arXiv:2606. 10547v1 Announce Type: cross Abstract: Energy Dispersive X-ray (EDX) tomography in Scanning Transmission Electron Microscopy (STEM) enables 3D compositional and elemental mapping at the nanoscale, but its use is limited by restricted tilt ranges and low-dose conditions required to avoid beam damage.
By Daniel del Pozo Bueno, Serge Brosset, Theo Monniez, Gabriele Navarro, Philippe Ciuciu, Zineb Saghi
arXiv:2606. 16212v1 Announce Type: cross Abstract: Sparse-view CT reduces radiation dose and scanning time by acquiring fewer projection views, but angular undersampling makes reconstruction severely ill-posed, causing streak artifacts, structural blurring, and loss of fine details.
By Jigang Duan, Jiayi Wang, Heran Wang, Ping Yang, Genwei Ma, Xing Zhao
X-ray computed tomography reconstruction is an ill-posed inverse problem, particularly in low-dose and sparse-angle settings where measurements are noisy and incomplete. While learned reconstruction methods such as the Learned Primal-Dual algorithm achieve strong performance, they typically rely on supervised training with access to ground-truth data, which is often unavailable in practice.
arXiv:2608. 08919v1 Announce Type: cross Abstract: During standard radiotherapy planning, repeated CT acquisitions are often required for patient registration, verification, and adaptive planning, resulting in increased cumulative X-ray dose.
By Alzahra Altalib, Chunhui Li, Christopher Hamill Taylor, Sankar Pillai, Alessandro Perelli
arXiv:2606. 26991v1 Announce Type: cross Abstract: X-ray computed tomography reconstruction is an ill-posed inverse problem, particularly in low-dose and sparse-angle settings where measurements are noisy and incomplete.
By Antti S\"allinen, Siiri Rautio, Santeri Kaupinm\"aki, Andreas Hauptmann
arXiv:2608. 15246v1 Announce Type: cross Abstract: Sparse-view computed tomography (CT) reduces radiation dose by acquiring fewer projection views, but the resulting inverse problem is highly ill-posed and often produces severe streak artifacts.
By Tran Xuan Hieu Le, Doanh C. Bui, Vu Trung Duong Le, Hoai Luan Pham, Khang Nguyen, Mai K. Nguyen, Tu Bao Ho, Yasuhiko Nakashima