arXiv:2609.10376v1 Announce Type: new
Abstract: Sparse-view X-ray 3D reconstruction is essential for reducing radiation exposure, but recovering a density field from a handful of X-ray projections is...
By Pranav Poudel, Florence Dell'Aniello Picard, Nairouz Shehata, Fr\'ed\'eric Lavoie, Herve Lombaert
Sparse-view X-ray 3D reconstruction is essential for reducing radiation exposure, but recovering a density field from a handful of X-ray projections is severely ill-posed. Recently, 3D Gaussian Splatt...
The paper introduces LiftXR, a geometry‑guided framework that first reconstructs a 3D anatomical layout from bi‑planar X‑ray images and then uses this layout to guide CT volume reconstruction. An anatomical parser refines the layout by analyzing the reconstructed CT, enabling region‑specific intensity calibration. Experiments on two public datasets show LiftXR surpasses recent X‑ray‑to‑CT methods and improves downstream segmentation performance.
By Yifei Wu, Yicheng Wu, Qiang Ma, Qi Chen, Renyang Gu, Xinyu Liu, Yongsheng Pan, Yong Xia
arXiv:2606. 19867v1 Announce Type: cross Abstract: Computed Tomography (CT) is essential for diagnosing pediatric craniofacial abnormalities, yet poses radiation risks to developing anatomies.
By Dong Yeong Kim, Jaewon Choi, Youmin Shin, Jungyu Lee, Myeongseop Kim, Jinwook Choi, Joo Whan Kim, Young-Gon Kim
SparseTokenGS is a Gaussian-based, feed-forward method for sparse-view cone-beam CT reconstruction that uses a reusable token pool to maintain scan-wide context during decoding. Anchor Token Fusion and Point-Token Attention query this shared pool at anchors and query coordinates, preserving local Gaussian priors while enabling reconstruction in a single forward pass without per-scan optimization. Experiments on chest, dental, volcanic rock, and chicken datasets show that SparseTokenGS achieves superior reconstruction quality, achieving 29.51 dB PSNR and 0.842 SSIM from only six dental projections and maintaining separable tooth-and-pulp structures for root‑canal localization.
By Zihan Deng, Zhenzhen Gong, Yujie Liu, Jiaxin Gong, Dingkun Liu, Kexian Xie, Yixing Huang, Peng Jin, Tianye Niu, Zhisheng Wang, Fenglin Liu, Hongming Shan, Lequan Yu
Sparse-view cone-beam computed tomography is widely used for fast, low-dose volumetric imaging and lesion localization in dentistry and image-guided interventions, but it introduces severe artifacts....
arXiv:2609.26756v1 Announce Type: new
Abstract: X-ray is medicine's most widely used imaging modality, yet remains among its least quantitative. Unlike volumetric modalities like CT or MRI, X-ray col...
By Victor Ion Butoi, Vivek Gopalakrishnan, John V. Guttag, Adrian V. Dalca, Neel Dey
Radiative Gaussian Splatting for Efficient X-ray Novel View Synthesis proposes X‑Gaussian, a 3D Gaussian splatting‑based method for X‑ray reconstruction. It introduces a radiative Gaussian point cloud model that ignores view direction, a Differentiable Radiative Rasterization (DRR) with CUDA, a Radiative Gaussian Volume Querying (RGVQ) for continuous attenuation fields, and an Angle‑pose Cuboid Uniform Initialization (ACUI) strategy using scanner parameters. The approach achieves state‑of‑the‑art novel view synthesis and CT reconstruction performance while reducing training time and inference speed significantly.
By Yuanhao Cai, Yixun Liang, Jiahao Wang, Angtian Wang, Yulun Zhang, Xiaokang Yang, Zongwei Zhou, Alan Yuille
AnyCXR is a unified framework that performs multi-organ segmentation on chest X-rays taken at any projection angle using only synthetic data. It employs a Multi-stage Domain Randomization engine to generate over 100,000 anatomically accurate synthetic radiographs from 3D CT volumes, and a Conditional Joint Annotation Regularization strategy to learn from partial, imperfect labels by enforcing anatomical consistency in a latent space. Trained solely on synthetic data, AnyCXR achieves strong zero-shot generalization on real-world datasets, accurately delineating 54 anatomical structures across PA, lateral, and oblique views, and supports downstream clinical tasks such as cardiothoracic ratio estimation, spine curvature assessment, and disease classification.
By Zifei Dong, Wenjie Wu, Jinkui Hao, Tianqi Chen, Ziqiao Weng, Bo Zhou
arXiv:2610.09253v1 Announce Type: new
Abstract: Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric info...
By Weicheng Dai, Shantanu Ghosh, Kayhan Batmanghelich
arXiv:2607. 23343v1 Announce Type: cross Abstract: Intraoperative 2D/3D registration aligns preoperative CT volumes with intraoperative X-ray or fluoroscopic images and is essential for image-guided interventions.
By Minheng Chen, Youyong Kong
arXiv:2609.22849v1 Announce Type: new
Abstract: In novel view synthesis and Computed Tomography (CT) reconstruction with sparse-view X-ray imaging, insufficient angular coverage leads to structural a...
By Lifeng Xing, Dequan Jin, Kunpeng Bu, Peigeng He, Shihui Ying