Hugging Face Trending Papers

X-Splat: Gaussian Splatting for 3D CBCT Generation from Single Panoramic Radiograph

Read the original on Hugging Face Trending Papers →

Generating a 3D dental volume from a single panoramic radiograph (PXR) could provide a low-radiation alternative to Cone-Beam Computed Tomography (CBCT), but the problem is highly underdetermined: panoramic acquisition integrates 3D attenuation along curved X-ray paths into a 2D image, leaving depth-resolved anatomy unobserved. Existing implicit and generative approaches often produce oversmoothed geometry or anatomically inconsistent hallucinations, lacking geometry-driven supervision and relying on smooth representations unable to precisely localize sharp anatomical boundaries.

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at Hugging Face Trending Papers.

arXiv AI
Aug 19

Learning Where and What to Lift for Bi-planar X-ray-to-CT Reconstruction

The paper introduces LiftXR, a geometry‑guided framework that first reconstructs a 3D anatomical layout from bi‑planar X‑ray images and then uses this layout to guide CT volume reconstruction. An anatomical parser refines the layout by analyzing the reconstructed CT, enabling region‑specific intensity calibration. Experiments on two public datasets show LiftXR surpasses recent X‑ray‑to‑CT methods and improves downstream segmentation performance.

By Yifei Wu, Yicheng Wu, Qiang Ma, Qi Chen, Renyang Gu, Xinyu Liu, Yongsheng Pan, Yong Xia
arXiv AI
Oct 31

SparseTokenGS: Gaussian-based Sparse-View CBCT Reconstruction via Reusable Token Pool

SparseTokenGS is a Gaussian-based, feed-forward method for sparse-view cone-beam CT reconstruction that uses a reusable token pool to maintain scan-wide context during decoding. Anchor Token Fusion and Point-Token Attention query this shared pool at anchors and query coordinates, preserving local Gaussian priors while enabling reconstruction in a single forward pass without per-scan optimization. Experiments on chest, dental, volcanic rock, and chicken datasets show that SparseTokenGS achieves superior reconstruction quality, achieving 29.51 dB PSNR and 0.842 SSIM from only six dental projections and maintaining separable tooth-and-pulp structures for root‑canal localization.

By Zihan Deng, Zhenzhen Gong, Yujie Liu, Jiaxin Gong, Dingkun Liu, Kexian Xie, Yixing Huang, Peng Jin, Tianye Niu, Zhisheng Wang, Fenglin Liu, Hongming Shan, Lequan Yu