arXiv:2607. 28759v1 Announce Type: cross Abstract: In X-ray CT, metallic objects cause beam hardening, photon starvation, and scattering, leading to projection inconsistency, streaks, dark bands, and structural distortions that compromise clinical diagnosis and quantitative analysis.
By Heran Wang, Jianing Sun, Xu Jiang, Genwei Ma, Xing Zhao, Jigang Duan
Cone-beam computed tomography (CBCT) enables volumetric reconstruction from X-ray projections, but suffers from severe artifacts--especially beam hardening--when imaging materials with high attenuation such as metals. These artifacts arise from the polychromatic nature of X-rays and are not properly addressed by conventional monochromatic reconstruction algorithms.
arXiv:2605.20470v2 Announce Type: replace-cross
Abstract: Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noi...
By Alzahra Altalib, Chunhui Li, Haytham Ahmad Alewaidat, Khaled Z. Alawneh, Ahmad Awad Qandeel, Alessandro Perelli
The paper introduces a one‑pass conditional 3D rectified flow (3D Flow) framework for denoising whole‑body PET images, employing an optimized non‑uniform sampling strategy and a linear‑interpolant velocity‑matching objective. It reconstructs a full 3D volume in about 30 seconds, dramatically faster than multi‑hour 3D diffusion models, while maintaining high global image quality and lesion conspicuity even at ultra‑low doses (down to 1/100 of standard). Zero‑shot transfer tests on independent clinical data demonstrate robust performance across datasets and unseen dose levels.
By Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo, Feng Yu
arXiv:2509. 21913v2 Announce Type: replace-cross Abstract: Background: Cone-beam computed tomography CBCT is a commonly used modality for image guided radiotherapy.
By Alzahra Altalib, Chunhui Li, Alessandro Perelli
arXiv:2603.26509v2 Announce Type: replace
Abstract: Computed tomography (CT) provides rich 3D anatomical detail but is often constrained by high radiation exposure, substantial costs, and limited ava...
By Martin Rath, Morteza Ghahremani, Yitong Li, Ashkan Taghipour, Marcus Makowski, Christian Wachinger
arXiv:2606. 09953v1 Announce Type: cross Abstract: Head computed tomography (CT) typically uses sub-millimeter in-plane resolution but 2-5 mm through-plane spacing, creating substantial anisotropy that degrades multiplanar reconstructions, volumetric measurements such as hematoma volume estimation, and downstream algorithms that assume near-isotropic voxels.
By Luis Cort\'es Ferre, Miguel A. Guti\'errez-Naranjo, Marcin Balcerzyk
The paper introduces $K$-NeAS, a scalable neural architecture for multi-material CT reconstruction that replaces separate material networks with a shared latent backbone and a differentiable $K$-material soft selector. It automates attenuation bounds using a Gaussian Mixture Model and adds a scheduled auxiliary floater loss to reduce geometric hallucinations in sparse-view settings. Evaluated on four clinical CBCT datasets, $K$-NeAS achieves higher 3D volumetric fidelity—up to a 1.88 dB PSNR gain over a single-material baseline—and shows improved robustness under extreme sparsity, outperforming baselines by up to 1.17 dB.
By Daksh K. Shah, Emmanouil Nikolakakis, Razvan Marinescu
The paper examines how residual misalignments from registration procedures introduce structured label noise in supervised synthetic CT (sCT) generation. It shows that voxel‑wise metrics are heavily influenced by the consistency between training and evaluation registrations, and that training with anatomically consistent registrations reduces variability and improves robustness. Introducing a perceptual loss based on a pretrained Segment Anything encoder yields sharper, more anatomically coherent sCT and highlights the need for anatomy‑oriented evaluation.
By Valentin Boussot, Cedric Hemon, Caroline Lafond, Jean-Claude Nunes, Jean-Louis Dillenseger
arXiv:2606. 15370v1 Announce Type: cross Abstract: This work demonstrates a full reproduction and extension of MNet, a hybrid 2D/3D convolutional network designed for anisotropic medical image segmentation.
By Kirsten Odendaal, Rade Bajic
arXiv:2609.24937v1 Announce Type: new
Abstract: Bone overlap can obscure abnormalities in chest radiographs, while scarce paired training data limit supervised bone suppression. We address this chall...
By Mrunmay Angaitkar, Piyush Kumar, Aarjav Satia, Pranav Rao, Ashish Mittal, Manoj Tadepalli, Preetham Putha
arXiv:2609.05484v1 Announce Type: cross
Abstract: Deep learning registration methods routinely stack two kinds of enhancement on a base network: architectural additions such as affine pre-alignment s...
By Nabira Rashid