Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric information. We propose PhyDiCT, a training-free fram...
arXiv:2603.26509v2 Announce Type: replace
Abstract: Computed tomography (CT) provides rich 3D anatomical detail but is often constrained by high radiation exposure, substantial costs, and limited ava...
By Martin Rath, Morteza Ghahremani, Yitong Li, Ashkan Taghipour, Marcus Makowski, Christian Wachinger
arXiv:2609.22849v1 Announce Type: new
Abstract: In novel view synthesis and Computed Tomography (CT) reconstruction with sparse-view X-ray imaging, insufficient angular coverage leads to structural a...
By Lifeng Xing, Dequan Jin, Kunpeng Bu, Peigeng He, Shihui Ying
The paper introduces Conditional Diffusion Posterior Alignment (CDPA), a method that scales diffusion-based sparse‑view CT reconstruction to large 3D volumes by conditioning a 2D U‑Net diffusion model on an initial 3D reconstruction and enforcing data‑consistency alignment. CDPA addresses high memory demands, limited 3D training data, and slice‑wise inconsistencies, achieving state‑of‑the‑art performance on synthetic and real Cone Beam CT data. The authors also demonstrate that the same approach improves fast denoising U‑Nets, delivering near‑diffusion quality at a fraction of the computational cost.
By Luis Barba, Johannes Kirschner, Benjamin Bejar
arXiv:2606. 16212v1 Announce Type: cross Abstract: Sparse-view CT reduces radiation dose and scanning time by acquiring fewer projection views, but angular undersampling makes reconstruction severely ill-posed, causing streak artifacts, structural blurring, and loss of fine details.
By Jigang Duan, Jiayi Wang, Heran Wang, Ping Yang, Genwei Ma, Xing Zhao
The paper introduces a high‑resolution Rectified Flow Matching model trained on 256×256 chest CT images to serve as a generative prior for CT reconstruction. A two‑stage training strategy—initial strong anatomically informed augmentation followed by fine‑tuning—helps mitigate overfitting and improve structural fidelity. When evaluated on various CT inverse problems, Flow Matching‑based reconstruction methods outperform diffusion‑based algorithms in PSNR, SSIM, and perceptual quality while requiring fewer sampling steps.
By Davide Evangelista
arXiv:2608. 15246v1 Announce Type: cross Abstract: Sparse-view computed tomography (CT) reduces radiation dose by acquiring fewer projection views, but the resulting inverse problem is highly ill-posed and often produces severe streak artifacts.
By Tran Xuan Hieu Le, Doanh C. Bui, Vu Trung Duong Le, Hoai Luan Pham, Khang Nguyen, Mai K. Nguyen, Tu Bao Ho, Yasuhiko Nakashima
arXiv:2609.37605v1 Announce Type: cross
Abstract: Supervised deep learning has advanced sparse-view tomographic reconstruction. However, conventional models, which typically map filtered back-project...
By AmirEhsan Khorashadizadeh, Benjam\'in B\'ejar
arXiv:2607. 02998v1 Announce Type: cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.
By Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
arXiv:2607. 02998v2 Announce Type: replace-cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.
By Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
The paper introduces a 3D-CLIP encoder trained with structured hard negatives to improve vision‑language alignment for text‑to‑CT generation. This encoder drives a latent diffusion model that operates directly in 3D latent space, eliminating spatial artifacts from super‑resolution pipelines. Experiments on the CT‑RATE dataset show state‑of‑the‑art image fidelity and factual correctness across 18 pathological conditions, with lower inference time and GPU memory usage than competing methods.
By Daniele Molino, Camillo Maria Caruso, Filippo Ruffini, Paolo Soda, Valerio Guarrasi
arXiv:2506. 00633v3 Announce Type: replace-cross Abstract: Generating semantically controllable 3D CT volumes from radiology reports requires more than a rich text encoder, it requires vision-language alignment grounded in volumetric space.
By Daniele Molino, Camillo Maria Caruso, Filippo Ruffini, Paolo Soda, Valerio Guarrasi