The study evaluates four deep‑learning segmentation architectures—Unet, PSPNet, Linknet, and FPN—paired with six pre‑trained encoders to predict COVID‑19 lesions in CT images. Experiments on three COVID‑19 CT datasets show high accuracy, achieving a maximum binary F1‑score of 98% and multi‑class F1‑scores of 75% and 77%. The work aims to provide a standardized performance benchmark for medical image segmentation and a reference for other imaging scenarios.
By Sarmad Khan, Basim Azam, Arslan Shaukat
The paper presents a two‑pipeline framework for retinal fundus analysis that combines four‑class disease classification with vessel segmentation. It fine‑tunes eight ImageNet‑pretrained CNNs on the FIVES dataset, applies five gradient‑based explanation methods to assess model interpretability, and benchmarks ten U‑Net variants—including transformer‑based and attention‑enhanced architectures—on the FIVES and DRIVE datasets. The best classification results come from ResNet101 (94.17% accuracy), while the strongest segmentation performance is achieved by Attention U‑Net with a ResNet101V2 backbone, improving DRIVE IoU from 60.80% to 64.83%.
By Fatema Tuj Johora Faria, Mukaffi Bin Moin, Pronay Debnath, Asif Iftekher Fahim, Faisal Muhammad Shah
arXiv:2607. 10357v1 Announce Type: cross Abstract: The automatic detection and classification of cardiovascular disease (CVD) from computed tomography (CT) images plays an important role in clinical practice.
By Yash Shah, Omar Todd, Philipp Seeb\"ock, Georg Langs, Ben Glocker, Raghav Mehta
Accurate coronary Digital Subtraction Angiography (DSA) vessel segmentation is essential for computer-aided diagnosis and treatment planning of coronary artery disease (CAD). However, thin low-contrast vessels, background interference, and severe vessel-background class imbalance make reliable segmentation of weak distal branches and vessel boundaries challenging.
arXiv:2609.01598v1 Announce Type: new
Abstract: Accurate segmentation of vascular structures in digital subtraction angiography (DSA) images remains challenging due to the thin, elongated, and branch...
By Asees Kaur, Suzanne S. Sindi, Erica M. Rutter
arXiv:2608. 15915v1 Announce Type: cross Abstract: Lung cancer remains the leading cause of cancer-related mortality worldwide, while histopathological diagnosis is often affected by inter-observer variability and the substantial workload associated with manual slide examination.
By Hadi Hasan, Safaa Salman, Lama Sleem, Ralph Mouawad, Ali Chehab
arXiv:2607. 23371v1 Announce Type: cross Abstract: Vascular segmentation is a standard procedure for clinical diagnosis, yet the specific visual features determining model decisions remain poorly understood.
By Weslley dos Santos Silva, Cesar Henrique Comin
arXiv:2609.22631v1 Announce Type: new
Abstract: Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction...
By Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
arXiv:2606. 17437v1 Announce Type: cross Abstract: Automated classification of standard echocardiographic views is crucial for efficient clinical workflow but faces three main challenges.
By Bo Gou, Jicheng Zhang, Jianlong Xiong, Tao He, Bentian Liu, Hai Wu, Yijiao Wang, Yu Zhang, Yujia Yang, Yun Dai, Jian Liu, Jie Wang
Vascular segmentation is a standard procedure for clinical diagnosis, yet the specific visual features determining model decisions remain poorly understood. This paper investigates the visual cues Convolutional Neural Networks (CNNs) use to segment blood vessels across two distinct imaging domains: fluorescence microscopy and retinal fundus photography.
OptiModNet is a lightweight UNet‑Transformer hybrid designed for optic disc and cup segmentation. It incorporates grouped‑query and channel attention across multiple stages, along with an Aggregated Pyramid Loss to improve gradient flow and structural consistency. Evaluated on the REFUGE2 dataset, it surpasses existing methods by over 2.5 % while using only 3.73 GFLOPs and 1.93 M parameters.
By Soumili Ghosh, Debapriya Roy, Aryan Das, Bikash Santra
The paper introduces a physics-informed deep learning framework that reconstructs 3D coronary geometry from dual-view angiography and predicts velocity and pressure fields using a decoupled network with embedded physical priors. Across 32 patients and four flow conditions, the model achieved a trans‑stenotic pressure‑drop error of 2.02% and velocity/pressure relative‑L2 errors of 0.054 and 0.023, respectively, while matching hospital‑measured FFR with 93.8% diagnostic accuracy. The pipeline completes the full angiography‑to‑hemodynamics conversion in about 20 minutes per patient and supports sparse‑data assimilation for revascularization planning.
By Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye, Qiang Luo, Mao Chen, Wenqi Hu