arXiv:2609.15550v1 Announce Type: cross
Abstract: X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D pro...
By Deyu Meng, Mojtaba Lashgari, Yiying Wang, Abhirup Banerjee
The paper introduces a physics-informed deep learning framework that reconstructs 3D coronary geometry from dual-view angiography and predicts velocity and pressure fields using a decoupled network with embedded physical priors. Across 32 patients and four flow conditions, the model achieved a trans‑stenotic pressure‑drop error of 2.02% and velocity/pressure relative‑L2 errors of 0.054 and 0.023, respectively, while matching hospital‑measured FFR with 93.8% diagnostic accuracy. The pipeline completes the full angiography‑to‑hemodynamics conversion in about 20 minutes per patient and supports sparse‑data assimilation for revascularization planning.
By Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye, Qiang Luo, Mao Chen, Wenqi Hu
The paper presents an anatomy‑aligned surface learning framework for reconstructing patient‑specific 4D myocardial surfaces from sparsely sampled short‑axis cine MRI. By parameterizing epicardial and endocardial surfaces on a shared circumferential‑longitudinal UV domain, the method transforms irregular 3D reconstruction into structured coordinate‑field completion, enabling explicit correspondence across subjects and cardiac phases. Experiments on three public datasets show the approach outperforms mesh‑based and implicit methods, achieving Chamfer distances around 2.6–2.9 mm and preserving ventricular function with small errors in volume and ejection fraction.
By Xiaohan Yuan, Xuan Yang, Qingya Li, Yangang Wang, Lei Li
Patient-specific 4D myocardial reconstruction from cine MRI supports quantitative functional assessment, regional motion analysis, and simulation-based modeling. However, routinely acquired short-axis...
Multi-view reasoning in coronary X-ray angiography is inherently a cross-projection geometric problem, yet automated report generation in this setting remains largely unexplored. The 3D vascular topology leads to projection-dependent branch overlap and foreshortening, rendering single-view modeling fundamentally incomplete and unstable for lesion localization and stenosis grading.
ReG-SAM is a SAM-based framework designed for 2D vessel segmentation in medical images. It introduces reference graph prompt embeddings (GPEs) and vascular prototype embeddings (VPEs) to capture global spatial and fine-grained modality-specific vessel features, respectively. By building a modality-wise vascular database and learning these embeddings from reference masks, ReG-SAM consistently outperforms existing baselines across 19 datasets, especially on thin vessels.
By Donghang Lyu, Zichen Zhang, Oleh Dzyubachyk, Marius Staring
arXiv:2608. 12274v1 Announce Type: cross Abstract: Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy.
By Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou, Ahmed I. Ghanem, Joshua P. Kim, Justine Cunningham, Hassan Bagher-Ebadian, Dongxiao Zhu, Kundan S. Thind
arXiv:2606. 02639v1 Announce Type: cross Abstract: We identify and resolve a previously unreported failure mode in TensoRF when applied to X-ray attenuation fields: the default density shift of -10, originally introduced for RGB scene reconstruction, suppresses density gradients and prevents sparse-view medical reconstruction regardless of learning rate or regularization strategy.
By Spoorthi M, Suja Palaniswamy
arXiv:2606. 05375v1 Announce Type: cross Abstract: Optical coherence tomographic angiography (OCTA) is a powerful technique for imaging retinal microvasculature.
By Yukun Guo, Min Gao, Tristan T. Hormel, Steven T. Bailey, Thomas S. Hwang, Yali Jia
The paper presents a deep learning super‑resolution framework for 4D flow MRI of carotid arteries, using convolutional block attention modules to focus on clinically relevant spatial features and reduce noise. Trained on 120 patients with 240 stenosed carotid arteries, the model leverages patient‑specific CFD simulations as high‑resolution ground truth. Results show a significant reduction in RMSE and improved reconstruction of complex flow patterns compared to a baseline without attention.
By Ali Mokhtari, Dominik Obrist
arXiv:2607. 23343v1 Announce Type: cross Abstract: Intraoperative 2D/3D registration aligns preoperative CT volumes with intraoperative X-ray or fluoroscopic images and is essential for image-guided interventions.
By Minheng Chen, Youyong Kong
arXiv:2608. 19965v1 Announce Type: cross Abstract: Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology.
By Sidi Mohamed Sid'El Moctar, Nicolas Vitry, H\'el\`ene Bouvrais