arXiv:2609.15550v1 Announce Type: cross
Abstract: X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D pro...
By Deyu Meng, Mojtaba Lashgari, Yiying Wang, Abhirup Banerjee
PPCAR-Net is a neural network that reconstructs 3‑D coronary artery centrelines and radii from a sparse set of X‑ray angiographic views. It predicts a branch‑structured centreline-and‑radius representation directly, avoiding explicit point matching or triangulation. The method refines geometry and radius estimates using projection‑guided refiners and achieves real‑time performance with strong centreline accuracy, especially for the right coronary artery.
By Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo
arXiv:2610.20509v1 Announce Type: cross
Abstract: Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing...
By Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu
The paper introduces a physics-informed deep learning framework that reconstructs 3D coronary geometry from dual-view angiography and predicts velocity and pressure fields using a decoupled network with embedded physical priors. Across 32 patients and four flow conditions, the model achieved a trans‑stenotic pressure‑drop error of 2.02% and velocity/pressure relative‑L2 errors of 0.054 and 0.023, respectively, while matching hospital‑measured FFR with 93.8% diagnostic accuracy. The pipeline completes the full angiography‑to‑hemodynamics conversion in about 20 minutes per patient and supports sparse‑data assimilation for revascularization planning.
By Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye, Qiang Luo, Mao Chen, Wenqi Hu
The paper presents an anatomy‑aligned surface learning framework for reconstructing patient‑specific 4D myocardial surfaces from sparsely sampled short‑axis cine MRI. By parameterizing epicardial and endocardial surfaces on a shared circumferential‑longitudinal UV domain, the method transforms irregular 3D reconstruction into structured coordinate‑field completion, enabling explicit correspondence across subjects and cardiac phases. Experiments on three public datasets show the approach outperforms mesh‑based and implicit methods, achieving Chamfer distances around 2.6–2.9 mm and preserving ventricular function with small errors in volume and ejection fraction.
By Xiaohan Yuan, Xuan Yang, Qingya Li, Yangang Wang, Lei Li
The paper introduces VasoMIM, a vascular anatomy‑aware masked image modeling framework for X‑ray angiogram analysis, which uses an anatomy‑guided masking strategy and an anatomical consistency loss to learn robust vascular representations. It also presents XA‑170K, the largest pre‑training dataset for X‑ray angiograms. Experiments on six datasets and four downstream tasks show that VasoMIM outperforms existing methods and achieves state‑of‑the‑art performance.
By De-Xing Huang, Chaohui Yu, Xiao-Hu Zhou, Tian-Yu Xiang, Qin-Yi Zhang, Mei-Jiang Gui, Rui-Ze Ma, Chen-Yu Wang, Nu-Fang Xiao, Fan Wang, Zeng-Guang Hou
Patient-specific 4D myocardial reconstruction from cine MRI supports quantitative functional assessment, regional motion analysis, and simulation-based modeling. However, routinely acquired short-axis...
Multi-view reasoning in coronary X-ray angiography is inherently a cross-projection geometric problem, yet automated report generation in this setting remains largely unexplored. The 3D vascular topology leads to projection-dependent branch overlap and foreshortening, rendering single-view modeling fundamentally incomplete and unstable for lesion localization and stenosis grading.
Vessel2Brain introduces an edge‑aware, multi‑scale flow matching framework that generates realistic 3D brain MRI volumes conditioned only on vascular label maps. By treating vessel‑guided synthesis as a conditional continuous flow, the method achieves stable training and preserves structural correspondence. Experiments on two public datasets show that Vessel2Brain outperforms existing generative models in reconstruction accuracy, structural consistency, and realism.
By Zhi Chen, Tianyang Zhang, Theodoros N. Arvanitis, Le Zhang
arXiv:2610.08983v1 Announce Type: new
Abstract: Generative inpainting of brain MRI volumes is essential for synthesizing healthy tissue in pathological regions, improving the accuracy and reliability...
By Arnela Hadzic, Franz Thaler, Simon Johannes Joham, Martin Urschler
Local2Mesh is a spatially localized contour‑to‑mesh framework that reconstructs 3‑D left ventricular geometry from sparse 2‑D cardiac MRI contours without requiring 3‑D mesh annotations. It corrects inter‑slice misalignment through geometry‑aware alignment and routes contour features to template vertices via a plane‑aware Local Router, then jointly uses local and global features to deform a template mesh. Experiments on M&Ms‑2 and ACDC datasets show superior geometric reconstruction, functional estimation, and disease classification compared to existing methods, with strong cross‑dataset generalization.
By Haoyu Wu, Ling Lin, Pascal Lef\`evre, Ruizhe Li, Xiaowu Sun
ReG-SAM is a SAM-based framework designed for 2D vessel segmentation in medical images. It introduces reference graph prompt embeddings (GPEs) and vascular prototype embeddings (VPEs) to capture global spatial and fine-grained modality-specific vessel features, respectively. By building a modality-wise vascular database and learning these embeddings from reference masks, ReG-SAM consistently outperforms existing baselines across 19 datasets, especially on thin vessels.
By Donghang Lyu, Zichen Zhang, Oleh Dzyubachyk, Marius Staring