arXiv:2608. 10505v1 Announce Type: new Abstract: Automated radiology report generation is advancing rapidly in response to the shortage of radiologists, yet unlike a perception model, existing generation models offer no control over the sensitivity-specificity trade-off of their diagnostic content.
By Ying Jin, Noel C. F. Codella, John Corring, Mu Wei, Dinei Florencio, Eric Horvitz
Automated radiology report generation is advancing rapidly in response to the shortage of radiologists, yet unlike a perception model, existing generation models offer no control over the sensitivity-specificity trade-off of their diagnostic content. Such control is essential because clinical scenarios diverge: emergency triage prioritizes sensitivity to reduce missed findings, whereas confirmatory interpretation emphasizes specificity to limit unnecessary interventions.
The paper introduces AdaConRed, a label‑free post‑conformal decision rule that transforms ambiguous conformal prediction sets into single class assignments for medical image classification. It employs a five‑stage pipeline—vision‑language generative augmentation, a frozen DermFoundation encoder, a lightweight MLP classifier, an entropy‑modulated margin‑aware nonconformity score, and a reassignment step for transitional samples—to improve accuracy on OSCC and ISIC benchmarks. Results show notable gains in malignant class accuracy while maintaining overall performance.
By Saibal Ghosh, Samarup Bhattacharya, Sanjoy Kumar Saha, Umapada Pal, Tapabrata Chakraborti
arXiv:2606. 20115v1 Announce Type: new Abstract: Conformal risk control (CRC) provides distribution-free guarantees on segmentation quality by calibrating a prediction-set threshold on held-out data.
By Nafis Fuad Shahid
CF‑NODE is a counterfactual test‑time adaptation framework designed for diabetic retinopathy grading across different cameras, clinics, and patient populations. It ranks internal spatial nodes by attention, feature magnitude, and similarity, then progressively attenuates the highest‑ranked nodes and calibrates predictions based on the stability of the expected grade response. Evaluated on five external datasets, CF‑NODE outperforms four existing methods, achieving higher AUC and macro‑F1 scores and providing more balanced recognition across severity levels.
By Sabarish G, Deepak Parashar
The paper proposes a training‑free evidence sufficiency assessment for on‑premise clinical AI agents, using a 4B model to score evidence from five ordered levels and a three‑tier sequential triage protocol. By calibrating a nominal top‑50% threshold and applying a one‑sided 95% Wilson lower confidence bound, the system selects between single‑run, five‑run consistency, or full‑deferral tiers to meet a 95% clinical target. Experiments on MIRA‑v2, CDM, VivaBench, and an in‑hospital liver malignancy cohort show that the single‑run top‑50% tier achieves a 98.91% pass rate, matching five‑run consistency while saving ~80% compute, while the full‑deferral tier caps false‑certification rates between 0.00% and 3.50%.
By Yiwen Qiu, Che Sun, Shu Shen, Wentao Wang
The paper argues that patient-level splitting, while preventing subject leakage, fails to eliminate confounders that span all folds, such as acquisition variables correlated with diagnosis. Using a five-question audit, the authors show that in the DMR-IR breast thermography dataset, the acquisition date alone predicts malignancy with an AUROC of 0.980, outperforming all imaging arms, and that the date can be decoded from image pixels. They find that only one imaging arm incorporates this confounder into its diagnostic score, and that controlling for the date collapses or barely preserves discrimination, highlighting the dataset’s limited cross-label same-date pairs and the need for additional confounder mitigation.
By Ignazio Gallo, Mattia Gatti, Leonardo Sgroi, Darwin Castillo, Yuliana Jim\'enez-Gaona, Nicola Landro
arXiv:2606. 20115v3 Announce Type: replace Abstract: Conformal risk control (CRC) provides distribution-free segmentation guarantees by calibrating a prediction-set threshold on held-out data.
By Nafis Fuad Shahid
arXiv:2609.38112v1 Announce Type: cross
Abstract: Many applications of black-box predictive models require controlling task-relevant error rates, such as missed lesion pixels in segmentation or misse...
By Bruno Marcondes e Resende, Helton Graziadei, Thiago Rodrigo Ramos, Rafael Izbicki
In high-stakes healthcare applications, machine learning models are frequently trained on data from one patient population and deployed on another, creating a distribution shift that degrades both acc...
arXiv:2607. 28696v1 Announce Type: new Abstract: Medical vision-language models (VLMs) can retain high observed marginal coverage after clinical shift while substantially under-covering an individual disease class.
By Mushir Akhtar, M. Tanveer
The paper introduces a decision‑aware evaluation protocol for medical image segmentation uncertainty that separates uncertainty estimation from deferral policy and assesses their joint performance under fixed review budgets. It reports metrics such as fixed‑budget error reduction, risk‑coverage behavior, region‑level review proxies, structural failure modes, and sensitivity to review assumptions. Experiments on retinal vessel, skin lesion, and polyp segmentation with various backbones and uncertainty estimators show that estimator rankings vary with review unit, uncertainty target, and cost model, and that boundary and thin‑structure failures are partly due to annotation ambiguity.
By Saket Maganti, Shreyank N Gowda