arXiv AI By Yiwen Qiu, Che Sun, Shu Shen, Wentao Wang

Evidence sufficiency assessment enables cost-effective review allocation in on-premise clinical AI agents

Read the original on arXiv AI →

The paper proposes a training‑free evidence sufficiency assessment for on‑premise clinical AI agents, using a 4B model to score evidence from five ordered levels and a three‑tier sequential triage protocol. By calibrating a nominal top‑50% threshold and applying a one‑sided 95% Wilson lower confidence bound, the system selects between single‑run, five‑run consistency, or full‑deferral tiers to meet a 95% clinical target. Experiments on MIRA‑v2, CDM, VivaBench, and an in‑hospital liver malignancy cohort show that the single‑run top‑50% tier achieves a 98.91% pass rate, matching five‑run consistency while saving ~80% compute, while the full‑deferral tier caps false‑certification rates between 0.00% and 3.50%.

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at arXiv AI.

arXiv AI
Nov 16

Proof-Grounded Patient-Specific Clinical Explanations from Knowledge-Graph Reasoning

The paper presents the CKG Clinical Explanation Engine, a post‑processing layer that transforms patient inference states and disease knowledge from a frozen, training‑free clinical knowledge‑graph reasoner into typed facts, explicit rule traces, provenance‑linked conclusions, and policy‑licensed recommendations. Evaluation on six workbooks covering 11,289 patients and 33,867 patient‑disease traces achieved perfect scores on IG‑range validity, knowledge provenance, cross‑sheet numerical fidelity, and fact/report field presence, with 99.29% consistency between availability and representation. The system also identified observed zero‑activation and partial evidence instances, passed a 30‑patient end‑to‑end audit, and demonstrated that rule replay and a bounded validator could detect all single‑fault mutants, establishing structural and implementation auditability while noting that clinical correctness and utility remain unestablished.

By Surajit Das
arXiv AI
Sep 11

Safe to Stop? Risk-Constrained Stopping for Sequential Clinical Diagnosis Agents

The paper introduces Cros, a risk‑constrained stopping layer for sequential clinical diagnosis agents that determines when to stop testing and make a diagnosis. Cros combines state‑wise error ranking, policy design on disjoint development splits, and exact tests of selective diagnostic error to provide finite‑sample guarantees. On a MIMIC‑derived abdominal‑pain benchmark, Cros achieves higher state‑error AUROC and lower selective error rates compared to baseline stopping methods, though its performance varies across development resplits.

By Yuexin Wu, Vasile Rus
arXiv AI
Oct 27

Patient-specific rubric-based evaluation of large language models across longitudinal cancer care

The study introduces NPC‑RubricBench, a phase‑aware benchmark that evaluates large language models (LLMs) on multistage clinical reasoning throughout the nasopharyngeal carcinoma care continuum. Using longitudinal data from 405 patients, the benchmark contains 941 patient‑phase units and 17,688 patient‑specific criteria across five dimensions, focusing strictly on decision‑time evidence. Evaluation of 30 general‑purpose and medical LLMs shows that strong diagnostic accuracy does not translate into better downstream care, with failure modes shifting from explicit decision errors in staging to decision omissions in initial work‑up and follow‑up, and reveals a trade‑off between prompt granularity, decision quality, evidence faithfulness, and safety adherence.

By Wei-Wei Zhang, Pengkai Wang, Yan Li, Zhijie Sang, Guan-Qun Zhou, Jun-Yan Li, Shu-Han Zhou, Pei-Wen Liu, Ting-Xi Tang, Min Tang, Zhitian Hou, Jianmin Wu, Jian Guan, i Lin, Hongxia Yang, Ying Sun