arXiv AI

Evidence sufficiency assessment enables cost-effective review allocation in on-premise clinical AI agents

The paper proposes a training‑free evidence sufficiency assessment for on‑premise clinical AI agents, using a 4B model to score evidence from five ordered levels and a three‑tier sequential triage protocol. By calibrating a nominal top‑50% threshold and applying a one‑sided 95% Wilson lower confidence bound, the system selects between single‑run, five‑run consistency, or full‑deferral tiers to meet a 95% clinical target. Experiments on MIRA‑v2, CDM, VivaBench, and an in‑hospital liver malignancy cohort show that the single‑run top‑50% tier achieves a 98.91% pass rate, matching five‑run consistency while saving ~80% compute, while the full‑deferral tier caps false‑certification rates between 0.00% and 3.50%.

arXiv AI
Nov 16

Proof-Grounded Patient-Specific Clinical Explanations from Knowledge-Graph Reasoning

The paper presents the CKG Clinical Explanation Engine, a post‑processing layer that transforms patient inference states and disease knowledge from a frozen, training‑free clinical knowledge‑graph reasoner into typed facts, explicit rule traces, provenance‑linked conclusions, and policy‑licensed recommendations. Evaluation on six workbooks covering 11,289 patients and 33,867 patient‑disease traces achieved perfect scores on IG‑range validity, knowledge provenance, cross‑sheet numerical fidelity, and fact/report field presence, with 99.29% consistency between availability and representation. The system also identified observed zero‑activation and partial evidence instances, passed a 30‑patient end‑to‑end audit, and demonstrated that rule replay and a bounded validator could detect all single‑fault mutants, establishing structural and implementation auditability while noting that clinical correctness and utility remain unestablished.

By Surajit Das
arXiv AI
Sep 11

Safe to Stop? Risk-Constrained Stopping for Sequential Clinical Diagnosis Agents

The paper introduces Cros, a risk‑constrained stopping layer for sequential clinical diagnosis agents that determines when to stop testing and make a diagnosis. Cros combines state‑wise error ranking, policy design on disjoint development splits, and exact tests of selective diagnostic error to provide finite‑sample guarantees. On a MIMIC‑derived abdominal‑pain benchmark, Cros achieves higher state‑error AUROC and lower selective error rates compared to baseline stopping methods, though its performance varies across development resplits.

By Yuexin Wu, Vasile Rus
arXiv AI
Oct 27

Patient-specific rubric-based evaluation of large language models across longitudinal cancer care

The study introduces NPC‑RubricBench, a phase‑aware benchmark that evaluates large language models (LLMs) on multistage clinical reasoning throughout the nasopharyngeal carcinoma care continuum. Using longitudinal data from 405 patients, the benchmark contains 941 patient‑phase units and 17,688 patient‑specific criteria across five dimensions, focusing strictly on decision‑time evidence. Evaluation of 30 general‑purpose and medical LLMs shows that strong diagnostic accuracy does not translate into better downstream care, with failure modes shifting from explicit decision errors in staging to decision omissions in initial work‑up and follow‑up, and reveals a trade‑off between prompt granularity, decision quality, evidence faithfulness, and safety adherence.

By Wei-Wei Zhang, Pengkai Wang, Yan Li, Zhijie Sang, Guan-Qun Zhou, Jun-Yan Li, Shu-Han Zhou, Pei-Wen Liu, Ting-Xi Tang, Min Tang, Zhitian Hou, Jianmin Wu, Jian Guan, i Lin, Hongxia Yang, Ying Sun
arXiv AI
Aug 3

Reasoning in Real World Clinical Care: Why Large Language Models Are Not Yet Safe for Autonomous Clinical Decision Support

arXiv:2607. 28677v1 Announce Type: new Abstract: LLM now pass medical licensing examinations and, in curated cases, can rival physicians at diagnostic reasoning.

By Shayndhan Sivanathan, Shravan Nageswaran, Mehdi Zadem, Ryaan Sultan, Nicolas von Mallinckrodt, Max Solovyev, Alexey Matyushkin, Sumon Sadhu, Gabriele C DeLuca, Sanjeeva Jeyaretna, James Hillis, Manoj Ramachandran, Prakash Jayakumar
arXiv AI
1d ago

Scalable Evaluation of Medical AI using Evidence-based Practice Recommendations

The paper presents an automated pipeline that extracts structured clinical criteria and decision trees from practice recommendations to create over 3,200 evaluation scenarios covering diagnosis, investigations, treatment, and complications. It applies this pipeline to 436 BMJ Best Practice monographs, generating region‑specific and temporally fresh scenario suites, and introduces a clinician‑calibrated autorater scoring AI responses on a 4‑point rubric. Experiments with Gemini models show that scaling, web search, and multi‑sample synthesis improve adherence, and that AI assistance raises clinician adherence from 50.5% to 70.0% in a primary‑care study.

By Teya Bergamaschi, Bijal Rajput, Akshay Goel, Matthew Thompson, Jacqueline Shreibati, Dave Steiner, Ashley Carrick, Mahvish Nagda, Dale R. Webster, Avinatan Hassidim, Katherine Chou, Yossi Matias, Po-Hsuan Cameron Chen, Christina Chen, Mike Schaekermann, Yun Liu, Anil Palepu
arXiv AI
Jul 29

PatientAgentBench: A Benchmark Framework for Evaluating Patient-Facing Health AI Agents

arXiv:2607. 25485v1 Announce Type: new Abstract: Health AI is evolving from answering questions to agentic systems that converse with patients, reason about health records, and act on their behalf.

By Korosh Vatanparvar, Ashutosh Joshi, Maria Xenochristou, Mohammad Abuzar Hashemi, Prasad Kasu, Deepak Bansal, Daniel Lopez-Martinez, Anchal Nema, Ramya Ganesan, Will Kimbrough, Alex Woody, Yadunandana Rao, Dilek Hakkani-Tur, Wilko Schulz-Mahlendorf
arXiv AI
Oct 2

OpenMTB-Audit: Exposing Over-Refusal and Clinical Expert Perspectives in LLM-Based Molecular Tumor Board Safety Evaluation

OpenMTB‑Audit is an open‑source benchmark that tests large language models on 500 synthetic non‑small cell lung cancer cases, covering five adversarial error categories and four safety labels: Supported, Partially Supported, Unsupported, and Insufficient Information. The study found that all eight tested LLMs over‑refused Partially Supported recommendations, collapsing labels to achieve high safety scores. A deterministic seven‑module framework, MTB‑AuditAgent, was introduced to reduce over‑refusal to 6.7% and reach 91.2% accuracy, while an oncologist annotation study highlighted disagreement around the boundary between information sufficiency and treatment optimization.

By Negin Ashrafi, Jia Luo, Stacey M. Frumm, Roxana Daneshjou
arXiv AI
Oct 15

GUIDE: Computationally Augmented Consensus for Trustworthy Clinical Practice Guidelines

arXiv:2610.16108v1 Announce Type: new Abstract: Maintaining up-to-date clinical practice guidelines (CPGs) is essential for evidence-based medicine, but rapid evidence growth and complex expert conse...

By Yuanfan Lin, Jie Di, Xujin He, Zhenzhe Lin, Jialing Chen, Ruiyang Li, Changyu Zheng, Yuanrui Shang, Weiqin Peng, Jingxi Qin, Xiong Wang, Dongxin Ye, Yining Huang, Guoqiang Li, Andi Xu, Sijia Yu, Ruixin Wang, Yahan Yang, Xiaohang Wu, Duoru Lin, Jingjing Chen, Zhenzhen Liu, Wenben Chen, Haotian Lin