The paper examines dataset contamination in public brain‑tumor MRI classification benchmarks, introducing a three‑layer framework—duplicate, patient, and source‑label leakage—to evaluate integrity. Audits of the three most used corpora reveal severe leakage: up to 28.8% of test images duplicate training images, 22.3% are byte‑identical, and 95.5% share patients with training data. Even after removing all leaked images, model accuracy remains unchanged, indicating that benchmark integrity cannot be inferred from stable leaderboard scores alone.
By Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
The study audits a class‑imbalance benchmarking protocol for multimodal chest X‑ray and EHR prediction using 29,083 MIMIC‑CXR images from 10,479 patients. It finds that record‑level splits create leakage: a simple lookup table can match the best model, and when evaluated on unseen patients all models collapse to predicting every case positive. After correcting for patient‑separated evaluation and refined labels, no imbalance strategy improves macro F2 beyond 0.01, tuned tree ensembles offer no advantage over logistic regression, and EHR variables alone remain at an all‑positive baseline, while image embeddings and diagnostic history provide the strongest signals.
By Dang-Khoa Bui, Quang-Huy Tran, Minh-Khoi Nguyen-Bui, Duc-Tuan Ngo, Thanh-Trong Tran, Tuan-Khoi Nguyen, Hoang-Anh Ngo
arXiv:2606. 11267v1 Announce Type: new Abstract: Data leakage -- contamination of a model with information unavailable at baseline -- is the dominant reproducibility failure in machine-learning-based science, yet detection tools require training code, external data, or domain expertise.
By Laurence A. Jacobs
The paper evaluates privacy‑aware federated learning for breast cancer imaging by comparing pretrained vision‑language models (CLIP, BiomedCLIP) and a ViT‑B/16 baseline on two public datasets, with and without differential privacy. All five models achieve high normal‑versus‑sick discrimination (ROC‑AUC 0.940‑0.990), but acquisition year alone attains 0.974, indicating potential confounding. Removing the text pathway keeps accuracy while cutting communication cost, while differential privacy lowers ROC‑AUC by 0.375 due to perturbing the full model state.
By Malithi Mithsara Wanniarachchi Kankanamge, Ning Yang, Sree Bash Debnath, Md Zobaer Islam, Abdur R. Shahid
The paper presents a method that derives BI‑RADS descriptors from breast MRI segmentation masks and uses a large language model to generate natural‑language rationales grounded in those descriptors. A BI‑RADS decision tree with eight quantitative radiomic measurements, lesion size, and component count informs the descriptors, which are then verbalised by the model. Applying this framework to 1,506 cases in the MAMA‑MIA dataset produced 3,012 reproducible BI‑RADS rationales with high faithfulness (99.98%) and counterfactual accuracy (99.3%).
By Hrishikesh Singh, Aarti Sharma, Divyanshu Kumar, Millie Pant
The paper presents an optimal‑transport based generative model that learns the distributional differences between healthy and diseased patients, producing per‑patient counterfactuals and label‑free attribution heatmaps. On tabular breast cancer data the model achieves high malignancy scoring (AUROC ≈ 0.91) and its attributions correlate moderately with a supervised classifier, yet it does not surpass logistic regression. In chest X‑ray experiments the transport heatmaps capture population‑level signals but fail to localize real lesions, revealing a synthetic‑to‑real gap that challenges the reliability of label‑free explanations.
By Lalit Kumar