The paper examines dataset contamination in public brain‑tumor MRI classification benchmarks, introducing a three‑layer framework—duplicate, patient, and source‑label leakage—to evaluate integrity. Audits of the three most used corpora reveal severe leakage: up to 28.8% of test images duplicate training images, 22.3% are byte‑identical, and 95.5% share patients with training data. Even after removing all leaked images, model accuracy remains unchanged, indicating that benchmark integrity cannot be inferred from stable leaderboard scores alone.
By Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
The study audits a class‑imbalance benchmarking protocol for multimodal chest X‑ray and EHR prediction using 29,083 MIMIC‑CXR images from 10,479 patients. It finds that record‑level splits create leakage: a simple lookup table can match the best model, and when evaluated on unseen patients all models collapse to predicting every case positive. After correcting for patient‑separated evaluation and refined labels, no imbalance strategy improves macro F2 beyond 0.01, tuned tree ensembles offer no advantage over logistic regression, and EHR variables alone remain at an all‑positive baseline, while image embeddings and diagnostic history provide the strongest signals.
By Dang-Khoa Bui, Quang-Huy Tran, Minh-Khoi Nguyen-Bui, Duc-Tuan Ngo, Thanh-Trong Tran, Tuan-Khoi Nguyen, Hoang-Anh Ngo
arXiv:2606. 11267v1 Announce Type: new Abstract: Data leakage -- contamination of a model with information unavailable at baseline -- is the dominant reproducibility failure in machine-learning-based science, yet detection tools require training code, external data, or domain expertise.
By Laurence A. Jacobs
The paper evaluates privacy‑aware federated learning for breast cancer imaging by comparing pretrained vision‑language models (CLIP, BiomedCLIP) and a ViT‑B/16 baseline on two public datasets, with and without differential privacy. All five models achieve high normal‑versus‑sick discrimination (ROC‑AUC 0.940‑0.990), but acquisition year alone attains 0.974, indicating potential confounding. Removing the text pathway keeps accuracy while cutting communication cost, while differential privacy lowers ROC‑AUC by 0.375 due to perturbing the full model state.
By Malithi Mithsara Wanniarachchi Kankanamge, Ning Yang, Sree Bash Debnath, Md Zobaer Islam, Abdur R. Shahid
The paper presents a method that derives BI‑RADS descriptors from breast MRI segmentation masks and uses a large language model to generate natural‑language rationales grounded in those descriptors. A BI‑RADS decision tree with eight quantitative radiomic measurements, lesion size, and component count informs the descriptors, which are then verbalised by the model. Applying this framework to 1,506 cases in the MAMA‑MIA dataset produced 3,012 reproducible BI‑RADS rationales with high faithfulness (99.98%) and counterfactual accuracy (99.3%).
By Hrishikesh Singh, Aarti Sharma, Divyanshu Kumar, Millie Pant
The paper presents an optimal‑transport based generative model that learns the distributional differences between healthy and diseased patients, producing per‑patient counterfactuals and label‑free attribution heatmaps. On tabular breast cancer data the model achieves high malignancy scoring (AUROC ≈ 0.91) and its attributions correlate moderately with a supervised classifier, yet it does not surpass logistic regression. In chest X‑ray experiments the transport heatmaps capture population‑level signals but fail to localize real lesions, revealing a synthetic‑to‑real gap that challenges the reliability of label‑free explanations.
By Lalit Kumar
arXiv:2607. 18678v1 Announce Type: cross Abstract: Breast MRI is highly sensitive for detecting breast tumors, but exams contain many slices and require substantial reading time.
By Mohammad Ali Dadrast, Hamid Usefi
arXiv:2607. 10466v1 Announce Type: new Abstract: Survival models can model time-to-event outcomes using partially observed data.
By Yanqi Xu, Hui Dai, Carlos Fernandez-Granda, Krzysztof J. Geras, Yiqiu Shen
arXiv:2610.33592v1 Announce Type: new
Abstract: Augmented large language model (LLM) systems have reported high benchmark accuracies in rare disease diagnosis, yet their real-world clinical utility r...
By Jian Yang, Peilin Liu, Xiaohan Li, Songda Li, Yu Cao, Yuqing Feng, Haomin Li
arXiv:2509. 19671v3 Announce Type: replace Abstract: Public datasets of Chest X-Rays (CXRs) have long been a popular benchmark for developing machine learning (ML) computer vision models in healthcare.
By Andrew Wang, Jiashuo Zhang, Michael Oberst
arXiv:2605. 02942v2 Announce Type: replace Abstract: Fairness studies of medical imaging AI often explain subgroup performance gaps through under-representation in the training data.
By Aya Elgebaly, Joris Fournel, Benjamin Laine J{\o}nch Jurgensen, Kamil Mikolaj, Anders Christensen, Martin Tolsgaard, Claes Ladefoged, Aasa Feragen
arXiv:2607. 14984v1 Announce Type: new Abstract: Per-subgroup fairness audits of medical image classifiers face a sample-size problem: minority subgroups in held-out test sets have so few samples that the resulting confidence intervals on per-subgroup performance are wider than the bias the audit is meant to detect.
By Mahmoud Ibrahim, Bart Elen, Chang Sun, Gokhan Ertaylan, Michel Dumontier