arXiv:2603. 04024v2 Announce Type: replace-cross Abstract: Ambiguous 3D medical image segmentation often involves boundaries where different expert delineations are non-identical yet clinically plausible.
By Chao Wu, Mahesh Bhosale, Kangxian Xie, Pouya Karimian, David Doermann, Mingchen Gao
arXiv:2509. 21913v2 Announce Type: replace-cross Abstract: Background: Cone-beam computed tomography CBCT is a commonly used modality for image guided radiotherapy.
By Alzahra Altalib, Chunhui Li, Alessandro Perelli
The paper introduces MedSegLatDiff, a diffusion-based framework that combines a variational autoencoder (VAE) with a latent diffusion model for medical image segmentation. By compressing images into a low-dimensional latent space, the method reduces noise and speeds up training, while a weighted cross‑entropy loss preserves tiny structures such as small nodules. Evaluated on ISIC‑2018, CVC‑Clinic, and LIDC‑IDRI datasets, MedSegLatDiff achieves state‑of‑the‑art Dice and IoU scores, generates diverse segmentation hypotheses, and produces confidence maps that enhance interpretability and reliability for clinical deployment.
By Ngoc Huynh Trinh, Hai Toan Nguyen, Son Ba Luong, Quoc Long Tran
arXiv:2607. 11941v1 Announce Type: cross Abstract: Computed tomography (CT) is a critical imaging modality for clinical diagnosis, but reducing radiation dose inevitably introduces severe noise and structured artifacts that degrade image quality.
By Md Imam Ahasan, Guangchao Yang, A F M Abdun Noor, Kah Ong Michael Goh, S. M. Hasan Mahmud, Md Mahfuzur Rahman
The paper introduces an unsupervised approach to medical image segmentation by training a Denoising Diffusion Probabilistic Model (DDPM) on 21 unlabeled abdominal CT scans to learn anatomical features. The encoder weights from the DDPM are transferred to a U‑Net for downstream segmentation on the BTCV multi‑organ dataset, resulting in a significant Dice score improvement for liver segmentation from 0.75 to 0.93. In low‑data regimes, diffusion‑pretrained models retain robust performance, achieving high Dice scores even with only 10% of labeled data.
By Akshat G, Divyansh Gupta, Shaleen Bhatnagar, Shilpa Ankalaki, Tusar Kanti Mishra
Acquiring pixel-level annotations for medical image segmentation is a severe bottleneck. Traditional U-Net architectures, while effective, learn local texture patterns and lack awareness of global ana...
The paper introduces DAMM‑Net++, a 2.5D neural network for thoracic organ‑at‑risk and target volume segmentation that tackles inter‑slice surface incoherence, small low‑contrast target failure, and lack of per‑case reliability signals. Its core is an anatomy‑change‑aware bidirectional selective state‑space memory that propagates context across axial slices, complemented by a boundary‑aware decoder and an uncertainty head for calibrated per‑voxel confidence. Evaluations on 2,146 patients, an external cohort, and a reader study show high Dice scores (0.955), low HD95 (3.78 mm), significant time savings (75‑80 %) for clinicians, and improved junior‑reader performance, with the system fully integrated into a clinical workflow.
By Galib Ahmed, Istiak Ahmed, Aritra Islam Saswato, Asib Mostakim Fony, Kazi Shahriar Sanjid, Md. Tanzim Hossain, Md. Anwarul Islam, Md. Nishan Khan, Md. Misbah Khan, Labiba Faiza Karim, Jobaer Rahman, S M Hasibul Hoque, Rahnuma Shahrin Rista, Kamruzzaman Rumman, Md Arifur Rahman, Syed Md. Akram Hussain, Mohammad Ashrafuzzaman Khan, M. Monir Uddin
arXiv:2607. 22727v1 Announce Type: cross Abstract: Medical image segmentation models often report high benchmark accuracy under ideal imaging conditions, yet their failures under clinical degradation can be quiet: sensor noise, patient motion, low- resolution acquisition, and contrast variability may all alter model behavior without producing an obvious warning.
By Pranav Kaliaperumal, Manisha Kaliaperumal
arXiv:2508.17299v2 Announce Type: replace
Abstract: Low-dose computed tomography (CT) denoising is crucial for reduced radiation exposure while ensuring diagnostically acceptable image quality. Despi...
By Zhihao Chen, Qi Gao, Zilong Li, Junping Zhang, Yi Zhang, Jun Zhao, Hongming Shan
arXiv:2605.20470v2 Announce Type: replace-cross
Abstract: Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noi...
By Alzahra Altalib, Chunhui Li, Haytham Ahmad Alewaidat, Khaled Z. Alawneh, Ahmad Awad Qandeel, Alessandro Perelli
The study explores how adding anatomical priors and active learning can improve the accuracy of deep learning models for segmenting the Clinical Target Volume (CTV) in gastric cancer radiotherapy. Using 100 retrospective CT scans, an nnU‑Net model trained on 10 expert‑contoured cases was enhanced with voxel‑wise anatomical prior maps and iterative active learning over four rounds. The combined approach raised the mean Dice Similarity Coefficient from 0.84 to 0.87, demonstrating that both techniques individually and together improve segmentation performance and generalizability.
By Phillip Chlap, Mark Lee, Trevor Leong, Matthew Field, Jason Dowling, Hang Min, Julie Chu, Jennifer Tan, Phillip K. Tran, Tomas Kron, Annette Haworth, Martin A. Ebert, Shalini K. Vinod, Lois Holloway
arXiv:2603. 05693v2 Announce Type: replace-cross Abstract: Accurate longitudinal analysis of brain MRI is often hindered by evolving lesions, which bias automated neuroimaging pipelines.
By Zahra Karimaghaloo, Dumitru Fetco, Haz-Edine Assemlal, Hassan Rivaz, Douglas L. Arnold