FoundDiff: Foundational Diffusion Model for Generalizable Low-Dose CT Denoising
Read the original on arXiv Computer Vision →The Flow has not summarised this story yet — read it at arXiv Computer Vision.
The Flow has not summarised this story yet — read it at arXiv Computer Vision.
arXiv:2607. 11941v1 Announce Type: cross Abstract: Computed tomography (CT) is a critical imaging modality for clinical diagnosis, but reducing radiation dose inevitably introduces severe noise and structured artifacts that degrade image quality.
The paper introduces a deep dictionary network (DDN) foundation model designed for ultra‑low‑dose CT (ULDCT) denoising across multiple organs. By cascading convolutional sparse coding layers with iterative soft‑thresholding, the architecture offers inherent interpretability, while dynamic dictionary and threshold modules enhance representation. The model is pre‑trained on over one million normal‑dose CT images and fine‑tuned on multi‑organ ULDCT datasets, achieving state‑of‑the‑art performance that consistently outperforms existing methods.
The paper introduces Dose-Aware Cold Diffusion (DACD), a physics-consistent framework that treats radiation dose as a continuous latent variable in a cold diffusion process for low-dose CT reconstruction. DACD combines dose-aware perception, multi-scale structural priors, and dose-calibrated step allocation to guide denoising, and adds an iterative forward-backprojection correction to enforce projection-domain consistency. Experiments on Mayo-2020, Mayo-2016, and LoDoPaB-CT show DACD outperforms existing diffusion-based and physics-guided methods, especially at ultra-low doses, and generalizes robustly across continuous, unseen dose levels.
arXiv:2509. 21913v2 Announce Type: replace-cross Abstract: Background: Cone-beam computed tomography CBCT is a commonly used modality for image guided radiotherapy.
arXiv:2608. 08919v1 Announce Type: cross Abstract: During standard radiotherapy planning, repeated CT acquisitions are often required for patient registration, verification, and adaptive planning, resulting in increased cumulative X-ray dose.
Noise2Match is a self‑supervised method for low‑dose CT denoising that uses an adaptive inter‑slice matching network to model and correct the label transition between adjacent slices. By ensuring the equal‑mean condition of the Noise2Noise framework, it theoretically matches supervised training with paired noisy‑clean data. The approach also extends effectively to low‑dose cone‑beam CT, outperforming existing image‑domain self‑supervised methods.