arXiv:2509. 21913v2 Announce Type: replace-cross Abstract: Background: Cone-beam computed tomography CBCT is a commonly used modality for image guided radiotherapy.
By Alzahra Altalib, Chunhui Li, Alessandro Perelli
The paper introduces a one‑pass conditional 3D rectified flow (3D Flow) framework for denoising whole‑body PET images, employing an optimized non‑uniform sampling strategy and a linear‑interpolant velocity‑matching objective. It reconstructs a full 3D volume in about 30 seconds, dramatically faster than multi‑hour 3D diffusion models, while maintaining high global image quality and lesion conspicuity even at ultra‑low doses (down to 1/100 of standard). Zero‑shot transfer tests on independent clinical data demonstrate robust performance across datasets and unseen dose levels.
By Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo, Feng Yu
arXiv:2608. 08919v1 Announce Type: cross Abstract: During standard radiotherapy planning, repeated CT acquisitions are often required for patient registration, verification, and adaptive planning, resulting in increased cumulative X-ray dose.
By Alzahra Altalib, Chunhui Li, Christopher Hamill Taylor, Sankar Pillai, Alessandro Perelli
arXiv:2607. 11941v1 Announce Type: cross Abstract: Computed tomography (CT) is a critical imaging modality for clinical diagnosis, but reducing radiation dose inevitably introduces severe noise and structured artifacts that degrade image quality.
By Md Imam Ahasan, Guangchao Yang, A F M Abdun Noor, Kah Ong Michael Goh, S. M. Hasan Mahmud, Md Mahfuzur Rahman
The paper introduces Conditional Diffusion Posterior Alignment (CDPA), a method that scales diffusion-based sparse‑view CT reconstruction to large 3D volumes by conditioning a 2D U‑Net diffusion model on an initial 3D reconstruction and enforcing data‑consistency alignment. CDPA addresses high memory demands, limited 3D training data, and slice‑wise inconsistencies, achieving state‑of‑the‑art performance on synthetic and real Cone Beam CT data. The authors also demonstrate that the same approach improves fast denoising U‑Nets, delivering near‑diffusion quality at a fraction of the computational cost.
By Luis Barba, Johannes Kirschner, Benjamin Bejar
arXiv:2603.26509v2 Announce Type: replace
Abstract: Computed tomography (CT) provides rich 3D anatomical detail but is often constrained by high radiation exposure, substantial costs, and limited ava...
By Martin Rath, Morteza Ghahremani, Yitong Li, Ashkan Taghipour, Marcus Makowski, Christian Wachinger
The paper introduces Dose-Aware Cold Diffusion (DACD), a physics-consistent framework that treats radiation dose as a continuous latent variable in a cold diffusion process for low-dose CT reconstruction. DACD combines dose-aware perception, multi-scale structural priors, and dose-calibrated step allocation to guide denoising, and adds an iterative forward-backprojection correction to enforce projection-domain consistency. Experiments on Mayo-2020, Mayo-2016, and LoDoPaB-CT show DACD outperforms existing diffusion-based and physics-guided methods, especially at ultra-low doses, and generalizes robustly across continuous, unseen dose levels.
By Md Imam Ahasan, Guangchao Yang, A F M Abdun Noor, S M Hasan Mahmud, Md Mahfuzur Rahman
arXiv:2608. 03430v1 Announce Type: cross Abstract: Four-dimensional cone beam CT (4D CBCT) is important for image-guided radiation therapy of thoracic cancers, but its use is limited by long scan times, causing high patient dose and motion/sparse-sampling artifacts.
By Ivo Herzig, Pascal Paysan, Daniel Barco, Marc Andr\'e Stadelmann, Frank-Peter Schilling, Igor Peterlik, Michal Walczak, Lijin Aryananda, Woo Sang Ahn, Rudolf Marcel F\"uchslin, Lukas Lichtensteiger
arXiv:2609.12860v1 Announce Type: new
Abstract: Computed tomography (CT) and positron emission tomography (PET) provide complementary anatomical and functional information for cancer diagnosis and tr...
By Sarita Mourya, Francesco Di Feola, Pierangelo Veltri, Paolo Soda
arXiv:2607. 02998v2 Announce Type: replace-cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.
By Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
The paper introduces a high‑resolution Rectified Flow Matching model trained on 256×256 chest CT images to serve as a generative prior for CT reconstruction. A two‑stage training strategy—initial strong anatomically informed augmentation followed by fine‑tuning—helps mitigate overfitting and improve structural fidelity. When evaluated on various CT inverse problems, Flow Matching‑based reconstruction methods outperform diffusion‑based algorithms in PSNR, SSIM, and perceptual quality while requiring fewer sampling steps.
By Davide Evangelista
arXiv:2607. 02998v1 Announce Type: cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.
By Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert