arXiv:2609.24725v1 Announce Type: cross
Abstract: Head-and-neck anatomy changes over a six-to-seven-week proton course, and the anatomy of a later week cannot be imaged when the plan is made. We pres...
By Yizhou Wu, Jie Ding, Justin Roper, Minglei Kang, Yuheng Li, Sibo Tian, David S. Yu, Xiaofeng Yang, Chih-Wei Chang
The paper introduces DAMM‑Net++, a 2.5D neural network for thoracic organ‑at‑risk and target volume segmentation that tackles inter‑slice surface incoherence, small low‑contrast target failure, and lack of per‑case reliability signals. Its core is an anatomy‑change‑aware bidirectional selective state‑space memory that propagates context across axial slices, complemented by a boundary‑aware decoder and an uncertainty head for calibrated per‑voxel confidence. Evaluations on 2,146 patients, an external cohort, and a reader study show high Dice scores (0.955), low HD95 (3.78 mm), significant time savings (75‑80 %) for clinicians, and improved junior‑reader performance, with the system fully integrated into a clinical workflow.
By Galib Ahmed, Istiak Ahmed, Aritra Islam Saswato, Asib Mostakim Fony, Kazi Shahriar Sanjid, Md. Tanzim Hossain, Md. Anwarul Islam, Md. Nishan Khan, Md. Misbah Khan, Labiba Faiza Karim, Jobaer Rahman, S M Hasibul Hoque, Rahnuma Shahrin Rista, Kamruzzaman Rumman, Md Arifur Rahman, Syed Md. Akram Hussain, Mohammad Ashrafuzzaman Khan, M. Monir Uddin
arXiv:2607. 11949v1 Announce Type: cross Abstract: We present a clinically deployed end-to-end auto-contouring system for cervical cancer radiotherapy planning, anchored by the Boundary-Aware Transformer with Region-Aware Mamba (BAT-RM), a hybrid architecture that integrates Sobel-gated boundary attention, a linear-time, multi-directional Mamba module for long-range context, and a boundary-skeleton-guided fusion gate.
By Istiak Ahmed, Kazi Shahriar Sanjid, Galib Ahmed, Md. Tanzim Hossain, Md. Anwarul Islam, Shahrukh Khan, Md. Ashrif Rahman Arian, Md. Nishan Khan, Md. Misbah Khan, S M Hasibul Hoque, Rahnuma Shahrin Rista, Md. Jobairul Islam, Sheikh Anisul Haque, Md Arifur Rahman, Syed Md. Akram Hussain, Syeda Nashra, Sayeed Shafayet Chowdhury, Md. Mostafa Kamal Sarker, M. Monir Uddin
arXiv:2509. 21913v2 Announce Type: replace-cross Abstract: Background: Cone-beam computed tomography CBCT is a commonly used modality for image guided radiotherapy.
By Alzahra Altalib, Chunhui Li, Alessandro Perelli
The paper introduces SWIFT, a Swin V2‑based model pretrained on 10,444 3D CT volumes and fine‑tuned for rectal cancer segmentation on T2‑weighted MRI. Four configurations—full fine‑tuning (SWIFT), decoder compression (SWIFTe), low‑rank adaptation (SWIFTe‑LoRA), and a LoRA‑decoder ensemble (SWIFTe‑LDE4)—were evaluated on 247 cases, showing that SWIFTe reduces parameters by 70.1% while improving tumor detection and radiomic agreement. The study also demonstrates a trade‑off between detection and boundary agreement, and highlights that SWIFTe‑LDE4 achieves the lowest calibration errors after temperature scaling.
By Aneesh Rangnekar, Jorge Tapias Gomez, Joseph O Deasy, Harini Veeraraghavan
CATCH is a conditional 3D diffusion model operating in an invertible Haar-wavelet domain designed to inpaint masked regions in T1‑weighted brain MRI with plausible, tumor‑free tissue while preserving observed anatomy. The model’s denoiser uses noisy target coefficients, voided‑image coefficients, and a signed mask, guided by tumor‑excluded wavelet reconstruction and a hole‑focused loss, and hard compositing ensures observed voxels remain unchanged. Experiments on BraTS data show that a weighted mixture of tumor‑derived, irregular‑blob, and ellipsoidal masks yields the best performance, achieving higher SSIM, PSNR, and lower MSE compared to fixed or random augmentation baselines.
By Simon Winther Albertsen, Hjalte Bjoernstrup, Said Djafar Said, Mostafa Mehdipour Ghazi
arXiv:2608.28705v1 Announce Type: cross
Abstract: Dose accumulation is increasingly important in adaptive radiation therapy and reirradiation, but its clinical validity depends on the performance of...
By Hengjie Liu, Manju Sharma, Xinyi Fu, Di Xu, Ke Sheng
arXiv:2609.13838v1 Announce Type: new
Abstract: Purpose: To develop and evaluate TotalSynth, a reusable pretrained framework for whole-body synthetic CT (sCT) generation from MRI and cone-beam CT (CB...
By Valentin Boussot, Cedric Hemon, Anais Barateau, Caroline Lafond, Jean-Claude Nunes, Jean-Louis Dillenseger
The paper introduces Observation‑Anchored Selective Assimilation (OASA) for forecasting tumor‑state proxies in post‑treatment glioma patients using serial MRI observations. OASA anchors the patient‑specific state with an intermediate observation and selectively updates it via a tiered rule and voxel‑wise soft gate, outperforming baseline methods in Dice score at certain thresholds. The approach is validated on 120 patient triplets and the code is publicly released.
By Yeonjae Jung, Minwoo Shin
arXiv:2608.29348v1 Announce Type: new
Abstract: Background: Patient details and acquisition metadata are important for clinical decisions, image quality control, and automated research pipelines, but...
By Jakob Wasserthal, Joshy Cyriac, Michael Bach, Kimia Mozahheb Yousefi, Minh-Son To, M\'at\'e Sik, C\'edric H\'emon, Thomas Weikert, Martin Segeroth
An integrated, web‑based platform has been developed to process diffusion‑weighted imaging (DWI) from MR‑guided linear accelerators and provide structured, literature‑grounded clinical interpretations. The system combines a deep‑learning pipeline for distortion correction, denoising, and IVIM/ADC fitting with a retrieval‑augmented generation (RAG) agent that references a curated knowledge base and traces each statement to its source. Independent expert ratings of nine glioblastoma cases showed high scores for clinical reasoning, citation quality, and overall utility, with a mean rating of 4.65 out of 5.
By Yunxiang Li, Yan Dai, Yen-Peng Liao, Jie Deng, Jill B De Vis, You Zhang
arXiv:2605.20470v2 Announce Type: replace-cross
Abstract: Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noi...
By Alzahra Altalib, Chunhui Li, Haytham Ahmad Alewaidat, Khaled Z. Alawneh, Ahmad Awad Qandeel, Alessandro Perelli