arXiv:2607. 12075v1 Announce Type: cross Abstract: Background: Deep learning models can classify thyroid nodules on ultrasound, but reliable clinical decision support also requires calibrated probabilities, uncertainty estimation, and selective referral, particularly under dataset shift.
By Md. Sadibul Hasan Sadib, Md. Mohayminul Mukit, Rahmatul Kabir Rasel Sarker, Tahmid Alam Tamim, Md. Monir Hossain Shimul
The study presents a calibrated deep‑ensemble model for classifying thyroid nodules on ultrasound, employing uncertainty‑aware selective prediction and conservative triage. Using nested cross‑validation on the TN5000 dataset, the model achieved high discrimination (AUC‑ROC 0.9377) and strong calibration (ECE 0.0138), while a risk‑coverage analysis guided 8.86% of cases to no FNA, 60% to FNA, and 31% to radiologist review. When applied to the TN3K dataset without recalibration, performance dropped markedly (AUC‑ROC 0.7870, ECE 0.1899), highlighting limited transportability under dataset shift.
By Md. Sadibul Hasan Sadib, Md. Mohayminul Mukit, Rahmatul Kabir Rasel Sarker, Tahmid Alam Tamim, Md. Nazmul Hasan, Md. Monir Hossain Shimul
The study investigates how image‑domain Poisson perturbations affect the classification of ischemic core/penumbra in non‑contrast CT slices. Using a CPAISD cohort, the authors compared direct ResNet‑18 classification with a denoising‑then‑classifying pipeline and found that denoising generally reduced performance. A prospective experiment with joint denoising‑classification models showed no statistically significant advantage over direct noisy classification, indicating limited robustness to Poisson noise.
By Rhea Ghosal, Ronok Ghosal, Eileen Lou
Purpose: To compare 2D, 2.5D, and 3D residual networks for pulmonary nodule malignancy-risk classification and evaluate momentum-contrast pretraining, mild augmentation, and exclusion of indeterminate...
arXiv:2608.28705v1 Announce Type: cross
Abstract: Dose accumulation is increasingly important in adaptive radiation therapy and reirradiation, but its clinical validity depends on the performance of...
By Hengjie Liu, Manju Sharma, Xinyi Fu, Di Xu, Ke Sheng
The paper introduces SWIFT, a Swin V2‑based model pretrained on 10,444 3D CT volumes and fine‑tuned for rectal cancer segmentation on T2‑weighted MRI. Four configurations—full fine‑tuning (SWIFT), decoder compression (SWIFTe), low‑rank adaptation (SWIFTe‑LoRA), and a LoRA‑decoder ensemble (SWIFTe‑LDE4)—were evaluated on 247 cases, showing that SWIFTe reduces parameters by 70.1% while improving tumor detection and radiomic agreement. The study also demonstrates a trade‑off between detection and boundary agreement, and highlights that SWIFTe‑LDE4 achieves the lowest calibration errors after temperature scaling.
By Aneesh Rangnekar, Jorge Tapias Gomez, Joseph O Deasy, Harini Veeraraghavan