arXiv:2609.39010v1 Announce Type: cross
Abstract: Objective: Head and neck (HN) proton therapy spans six to seven weeks of anatomical change, while offline replanning takes about a week. We present a...
By Yizhou Wu, Ryan J. Sanford, Huiqiao Xie, Jie Ding, Shupeng Chen, Tung-Ho Wu, Ping-Hsiu Wu, Justin Roper, Jun Zhou, Minglei Kang, Bill Stokes, Sibo Tian, David S. Yu, Xiaofeng Yang, Chih-Wei Chang
The paper introduces DAMM‑Net++, a 2.5D neural network for thoracic organ‑at‑risk and target volume segmentation that tackles inter‑slice surface incoherence, small low‑contrast target failure, and lack of per‑case reliability signals. Its core is an anatomy‑change‑aware bidirectional selective state‑space memory that propagates context across axial slices, complemented by a boundary‑aware decoder and an uncertainty head for calibrated per‑voxel confidence. Evaluations on 2,146 patients, an external cohort, and a reader study show high Dice scores (0.955), low HD95 (3.78 mm), significant time savings (75‑80 %) for clinicians, and improved junior‑reader performance, with the system fully integrated into a clinical workflow.
By Galib Ahmed, Istiak Ahmed, Aritra Islam Saswato, Asib Mostakim Fony, Kazi Shahriar Sanjid, Md. Tanzim Hossain, Md. Anwarul Islam, Md. Nishan Khan, Md. Misbah Khan, Labiba Faiza Karim, Jobaer Rahman, S M Hasibul Hoque, Rahnuma Shahrin Rista, Kamruzzaman Rumman, Md Arifur Rahman, Syed Md. Akram Hussain, Mohammad Ashrafuzzaman Khan, M. Monir Uddin
arXiv:2611.27876v1 Announce Type: cross
Abstract: Every few months, a cancer patient's CT scans decide whether treatment continues. 3D foundation models can now detect, segment, register and track le...
By Maximilian Rokuss, Jeya Maria Jose Valanarasu, Alejandro Lozano, Benjamin Hamm, Yannick Kirchhoff, Fabian Isensee, Klaus Maier-Hein
EPC‑RawDC is a 3‑D latent diffusion model that synthesises CT images from CBCT scans by enforcing two physics‑based constraints: a geometry‑equivariant projection loss and raw data consistency using scan‑specific CBCT projections. Trained on two clinical cohorts with different scanner geometries, the method achieved SSIM of 0.97 and improved PSNR and MAE over a baseline DDPM, reducing projection and equivariant errors by 55 % and 41 % respectively.
By Alzahra Altalib, Chunhui Li, Alessandro Perelli
The paper introduces Observation‑Anchored Selective Assimilation (OASA) for forecasting tumor‑state proxies in post‑treatment glioma patients using serial MRI observations. OASA anchors the patient‑specific state with an intermediate observation and selectively updates it via a tiered rule and voxel‑wise soft gate, outperforming baseline methods in Dice score at certain thresholds. The approach is validated on 120 patient triplets and the code is publicly released.
By Yeonjae Jung, Minwoo Shin
arXiv:2609.13838v1 Announce Type: new
Abstract: Purpose: To develop and evaluate TotalSynth, a reusable pretrained framework for whole-body synthetic CT (sCT) generation from MRI and cone-beam CT (CB...
By Valentin Boussot, Cedric Hemon, Anais Barateau, Caroline Lafond, Jean-Claude Nunes, Jean-Louis Dillenseger
arXiv:2608.29348v1 Announce Type: new
Abstract: Background: Patient details and acquisition metadata are important for clinical decisions, image quality control, and automated research pipelines, but...
By Jakob Wasserthal, Joshy Cyriac, Michael Bach, Kimia Mozahheb Yousefi, Minh-Son To, M\'at\'e Sik, C\'edric H\'emon, Thomas Weikert, Martin Segeroth
arXiv:2610.33071v1 Announce Type: new
Abstract: Digital twins of cerebral perfusion relate tracer dynamics to cerebral blood flow (CBF), blood volume (CBV) and mean transit time (MTT), but must be da...
By Anh Duong Tran, Quang-Anh N. D., Toan Sy Pham, Trang H. Hoang, Minh N. Do, Duy Ton Mai, Huan X. Nguyen
arXiv:2509. 21913v2 Announce Type: replace-cross Abstract: Background: Cone-beam computed tomography CBCT is a commonly used modality for image guided radiotherapy.
By Alzahra Altalib, Chunhui Li, Alessandro Perelli
The paper presents a closed‑loop system for registering segmented CT fracture fragments to fluoroscopy, providing calibrated uncertainty bounds and flagging implausible or ambiguous fragments. After each shot, the system updates all fragment registrations, stops or plans the next view based on whether new views keep fragment positions within their bounds, and uses uncertainty‑driven planning to reduce the number of shots needed. Experiments on simulated fluoroscopy of 60 held‑out pelvic fractures show that 95% of the bounds cover 83% of unflagged fragments, with 91% of those within 5 mm, and that a simple rule requiring no fragment to move beyond its bound reduces false stops from 23% to 6% at a 2 mm threshold.
"whyItMatters":"The study demonstrates that calibrated uncertainty and view‑planning can make multi‑fragment 2D/3D registration reliable enough to guide pelvic fracture surgery, potentially improving surgical accuracy and efficiency."
By Bowen Xiang, Michael I. Miga
arXiv:2609.24560v1 Announce Type: new
Abstract: Confocal Laser Endomicroscopy (CLE) provides real-time, cellular-resolution optical biopsy but has a narrow field of view, which image mosaicing can ex...
By Ahmed Aboelela, Johannes Barcsay, Jana Friedhof, Miguel Gon\c{c}alves, Alexander Hann, Katharina Breininger
arXiv:2609.22377v2 Announce Type: replace-cross
Abstract: Intrathecal contrast-enhanced MRI shows how a tracer injected into the cerebrospinal fluid spreads through the brain, but requires repeated s...
By Qinghui Liu, Jon Andr\'e Ottesen, Thu Nguyen, Geir Ringstad, Ingrid Mossige, Siri Fl{\o}gstad Svensson, Atle Bj{\o}rnerud, Per Kristian Eide, Kyrre Eeg Emblem