The study introduces dLI-RADS, an interpretable AI system that estimates hepatocellular carcinoma probability from multiphase CT images of liver lesions while aligning with LI-RADS imaging concepts. By combining neural network predictions with handcrafted quantitative imaging features and logistic regression, dLI-RADS achieved 80% lesion-level accuracy, outperforming standard LI-RADS (74%) in a multicenter retrospective cohort. The method was validated using bootstrap non‑inferiority tests and external sensitivity comparisons.
By Emma Sarfati, Alexandre B\^one, Pietro Gori, Sisi Yang, Marc-Michel Roh\'e, Fran\c{c}ois Nicolas, Jeong-Min Lee, Jeong Hee Yoon, Maxime Ronot, Isabelle Bloch, Christophe Aub\'e
arXiv:2610.14226v1 Announce Type: cross
Abstract: Purpose : To develop and evaluate CAPTOR, a deep-learning vision-language foundation model for oncologic chest-abdomen-pelvis (CAP) CT interpretation...
By S\'el\'ena Jean-Mactoux, Sophie Loizillon, Ghina Jardali, Amandine Cromb\'e, Nathalie Lassau, Alexandre B\^one
Purpose: To compare 2D, 2.5D, and 3D residual networks for pulmonary nodule malignancy-risk classification and evaluate momentum-contrast pretraining, mild augmentation, and exclusion of indeterminate...
arXiv:2608. 07857v1 Announce Type: cross Abstract: Foundation models provide transferable CT representations, but predictions based directly on these embeddings are difficult to interpret.
By Fakrul Islam Tushar, Stephen Adamo, Geoffrey D. Rubin
The study compares 2D, 2.5D, and 3D residual networks for classifying pulmonary nodule malignancy risk using a retrospective LIDC‑IDRI cohort of 2,654 nodules. Models were trained with random initialization, momentum‑contrast pretraining, and mild data augmentation, and evaluated on patient‑disjoint splits. Augmented 2.5D models achieved the highest test Macro‑F1 (0.6537) and accuracy (0.6869), while 2D and 3D models performed lower, and pretraining generally reduced performance.
By Bahodir Nazarov, Zineb Gharib, Fatima Zazoul
LiFUSE introduces a unified frequency‑spatial self‑supervised pretraining framework for liver disease analysis on non‑contrast CT scans. The method employs a frequency branch that uses random band‑stop masking and spectrum reconstruction, and a spatial branch that performs hybrid‑granularity masked volumetric reconstruction, with a cross‑domain consistency scheme to fuse the two branches. Experiments on three clinical tasks and a public transfer setting demonstrate that LiFUSE consistently outperforms strong baselines, indicating its potential to enhance liver disease screening using low‑contrast NCCT images.
arXiv:2609.14106v1 Announce Type: new
Abstract: We evaluated parameter-efficient fine-tuning (PEFT) of the Segment Anything Model (SAM) for liver tumor segmentation in abdominal CT of colorectal live...
By Ramtin Mojtahedi, Mohammad Hamghalam, Jacob J. Peoples, Richard K. G. Do, Amber L. Simpson
FedHisto-PAST v2 is a parameter‑efficient, stain‑aware federated learning framework for cross‑site lung histopathology classification, combining a frozen HIBOU‑B foundation model with techniques such as paired‑view prediction, feature consistency, prototype learning, and adaptive aggregation. In a five‑client, non‑IID simulation and an exploratory LungHist700 cohort, the method achieved a Macro‑F1 of 0.7286 and a balanced accuracy of 0.7305, with the prediction‑level consistency component providing the most clear independent benefit. The framework updated only about 1.25% of the model parameters, demonstrating efficient adaptation while acknowledging limitations in privacy guarantees and clinical validation.
By Muhammad Muhtasim Shahriar, M. M. Golam Hafiz, Saad Aloteibi, Mohammad Ali Moni
arXiv:2608.28716v1 Announce Type: cross
Abstract: Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent impr...
By Savvas Saragiotis, Pieter C. Gort, Lotte J. S. Fleurkens-Ewals, Anna F. van Herwijnen, Marion Tops-Welten, L. D. Kampmeijer, Joost Nederend, Fons van der Sommen
arXiv:2610.18243v1 Announce Type: cross
Abstract: Given the growing global burden of liver tumors and diffuse liver diseases, non-contrast computed tomography (NCCT) is increasingly used for opportun...
By Hao Zhang, Yi Huang, Wei Liu, Yuan Gao, Zeju Li, Xu Han, Yu Shi, Ling Zhang, Ke Yan
The paper introduces two lightweight spectral adapters—Directional Spectral Adapter (DiSECT) and Spectral Instance-Guided Adapter (SiGA)—to adapt the Segment Anything Model (SAM) for accurate segmentation of colorectal liver metastases in contrast‑enhanced CT scans. SiGA achieves the highest single‑point Dice score of 0.77 and performs comparably to a 3D nnU‑Net baseline under no‑prompt inference, while DiSECT requires only 0.14 million trainable parameters. The study evaluates the adapters on 446 CT volumes across various prompting regimes, demonstrating that spectral adapters can efficiently adapt SAM with limited trainable parameters while maintaining strong segmentation accuracy.
By Ramtin Mojtahedi, Mohammad Hamghalam, Jacob J. Peoples, Natalie Gangai, Mithat Gonen, Yun Shin Chun, HyunSeon Christine Kang, Richard K. G. Do, Amber L. Simpson
The study introduces RCC-Align, a cross‑modal contrastive learning framework that aligns paired histopathology whole‑slide images and CT scans to enhance noninvasive grading of clear cell renal cell carcinoma (ccRCC). Using patient‑level five‑fold cross‑validation on TCGA and CPTAC cohorts, RCC‑Align achieved an AUC of 0.601 and AUPRC of 0.599 for low‑ versus high‑grade ccRCC classification, outperforming CT‑only baselines and showing stronger WSI‑CT embedding alignment. The approach relies solely on CT at inference, potentially aiding grading when biopsy is unsafe or limited by tumor heterogeneity.
By Amit Das, Tanmay Shukla, Naofumi Tomita, Faraz Farhadi, Jessica Sin, Ari Hakimi, Chad Vanderbilt, Jie-Fu Chen, Ritesh Kotecha, Weijie Ma, Bing Ren, Saeed Hassanpour