arXiv Computer Vision

A Novel Conditional Adversarial Diffusion Model for High-Fidelity OCT-to-OCT Image Translation and Precise Anti-VEGF Therapy Response Prediction in Diabetic Macular Edema

The paper introduces a conditional adversarial diffusion model that generates post‑treatment OCT images from baseline scans to predict anti‑VEGF therapy response in diabetic macular edema. Using 5‑fold cross‑validation on a US cohort (n=127) and external validation on an Iranian cohort (n=44), the model outperformed fourteen baseline and state‑of‑the‑art translation methods, achieving balanced accuracies of 85.7%–93.0% and 85.2%–95.3% at 10% and 20% central subfield thickness reduction thresholds. The framework aims to provide ophthalmologists with a noninvasive decision‑support tool for personalized therapy selection before treatment initiation.

arXiv Computer Vision
Aug 28

Automated 2D and 3D Segmentation of AMD and DME Lesions in OCT

This study presents four deep‑learning pipelines—two‑dimensional and three‑dimensional—for segmenting age‑related macular degeneration (AMD) and diabetic macular edema (DME) lesions in optical coherence tomography (OCT) images. The models achieve Dice scores between 0.76 and 0.82 and demonstrate strong volumetric and surface calibration (r_vol, r_surf ≥ 0.97) on an in‑domain validation set. Generalization was assessed on the OLIVES clinical cohort using proxy metrics such as biomarker AUROC, central subfield thickness correlation, and longitudinal concordance, showing that the predictions still track clinical biomarkers outside the training distribution, albeit with reduced strength.

By Lucia Sundberg, Zhihao Zhao, M. Ali Nasseri
arXiv Computer Vision
Sep 3

Evaluating Fundus-Specific Foundation Models for Diabetic Macular Edema Detection

The study evaluates fundus-specific foundation models (FM) for detecting diabetic macular edema (DME) in retinal images. It compares two popular FM—RETFound and FLAIR—against a lightweight EfficientNet-B0 backbone across multiple datasets (IDRiD, MESSIDOR-2, and OCT-and-Eye-FundusImages). Results indicate that FM do not consistently outperform fine‑tuned CNNs; EfficientNet-B0 often matches or exceeds FM performance, with FLAIR being the most competitive FM.

By Franco Javier Arellano, Jos\'e Ignacio Orlando
arXiv AI
Sep 1

Co-Annotator: Expert-Distilled ViT and VLM for Visual and Documentation Guidance in Age-Related Macular Degeneration

Co-Annotator is a clinical AI system that distills expert gaze and dictation into two guidance components: a gaze‑aligned Vision Transformer that highlights fixation‑aligned areas of interest (AOIs) and an ontology‑bounded vision‑language model that pre‑fills editable biomarker summaries for retinal OCT. In controlled studies, each modality independently improved diagnostic accuracy and biomarker generation, and when combined across two academic institutions, the system increased correct diagnoses per minute by 40% and reduced comment editing time by 67% without compromising accuracy.

By Ziheng "Leo" Li, Benjamin Freeman, Akshay Raman, Kavin Aravindhan Rajkumar, Xinxin Fang, Rishabh Srivastava, Steven Feiner, Kaveri A. Thakoor
arXiv Machine Learning
Oct 19

CF-NODE: Counterfactual Spatial Node Intervention for Test-Time Adaptation Under Domain Shift, Evaluated Across Five Diabetic Retinopathy Datasets

CF‑NODE is a counterfactual test‑time adaptation framework designed for diabetic retinopathy grading across different cameras, clinics, and patient populations. It ranks internal spatial nodes by attention, feature magnitude, and similarity, then progressively attenuates the highest‑ranked nodes and calibrates predictions based on the stability of the expected grade response. Evaluated on five external datasets, CF‑NODE outperforms four existing methods, achieving higher AUC and macro‑F1 scores and providing more balanced recognition across severity levels.

By Sabarish G, Deepak Parashar
arXiv AI
Nov 11

A Stage-Wise Explainable Pipeline for Arteriolar-to-Venular Ratio Estimation and Retinopathy Screening

The paper introduces a five‑stage, explainable pipeline for estimating the arteriolar‑to‑venular diameter ratio (AVR) from fundus images and for screening retinopathy. Each stage—vessel and artery‑vein masking, optic‑disc localization, vessel‑calibre estimation via a minimal‑chord boundary walk, and AVR calculation from dominant branches—produces inspectable intermediate outputs, and a threshold‑based rule yields the screening decision. In an exploratory cohort of 30 high‑resolution fundus images, the method achieved 96.7% accuracy, an F1‑score of 0.968, and an ROC‑AUC of 0.978, with ablation studies highlighting the impact of vessel pairing, calibre measurement, and aggregation.

By Sharan Sharmeela Karuppannan, Yoga Sri Varshan V, Subin Sahayam, Umarani Jayaraman
arXiv AI
Aug 3

DualDiT: A Conditional Dual-Output Diffusion Transformer for Joint OCT Image and Segmentation Mask Generation

arXiv:2607. 29337v1 Announce Type: cross Abstract: Background and Objective: Generating realistic medical images with anatomically accurate segmentation masks helps address the shortage of annotated data in medical imaging, particularly in optical coherence tomography (OCT) of mouse eyes, where manual retinal layer delineation is labour-intensive due to tiny structures and required expertise, resulting in scarce datasets.

By Fernando Garc\'ia-Torres, Roc\'io del Amor, Sandra Morales, \'Alvaro Barroso, Peter Heiduschka, Bj\"orn Kemper, Valery Naranjo
arXiv AI
Sep 21

Diagnostic-Guided Longitudinal Modeling for Forecasting Retinal Atrophy Progression

The study proposes a diagnostic-guided approach to choose between stochastic and deterministic longitudinal imaging models based on whether inter-visit changes are driven by disease progression or acquisition variability. Applied to a large, heterogeneous Optos fundus autofluorescence archive, the diagnostic revealed weak time-dependent changes and limited benefit from stochastic models, leading to the development of the deterministic Temporal Retinal U‑Net (TRU). TRU outperformed other classical and deep‑learning comparators on image‑level and eye‑specific progression metrics across held‑out and independent zero‑shot transfer cohorts, though with slightly lower precision in a smaller cross‑vendor cohort.

By Liyin Chen, Souvick Mukherjee, Ines Maria De Carvalho Lains, Nazlee Zebardast, Mengyu Wang, Tobias Elze, Jason I. Comander
arXiv Computer Vision
Oct 23

A Visual Grounding Benchmark for Retinal OCT with Multimodal Large Language Models

The paper introduces RetinaGroundBench, a new benchmark for visual grounding of retinal OCT images, featuring 815 B-scans annotated with 4,537 bounding boxes for 13 biomarkers across 8 diseases. It evaluates 27 multimodal large language models (MLLMs) and finds that visual grounding is largely unsolved, with the best model achieving only a macro F1 of 23.7%. The authors also present RetGrounder, an 8‑B parameter MLLM fine‑tuned for OCT, which raises grounding F1 to 33.9%, a 43% relative improvement.

By Ronald Fecso, Jos\'e Morano, Botond Fazekas, Paul Widmann-Sedlnitzky, Dorota Himel, Laetita Hinterhuber, Virginia Mares, Andreas Pollreisz, Hrvoje Bogunovi\'c
arXiv AI
Oct 27

FOCUS: Benchmarking Retinal Model Generalization from Foundation Vision Encoders to Multimodal LLMs

The paper introduces FOCUS, a cross‑dataset benchmark for retinal fundus models that evaluates vision‑only encoders, vision‑language dual encoders, and multimodal large language models across ten public datasets. It measures ranking performance, calibration, subgroup disparities, and image‑quality robustness for tasks such as diabetic retinopathy and glaucomatous optic neuropathy. Results show no single model family dominates, with vision‑only encoders ranking highest on average, while fine‑tuning improves in‑domain performance but varies in external transfer.

By David Restrepo, Chenwei Wu, Luis Filipe Nakayama, Miguel L. Martins, Stergios Christodoulidis, Maria Vakalopoulou, Enzo Ferrante
Hugging Face Trending Papers
Oct 22

A Visual Grounding Benchmark for Retinal OCT with Multimodal Large Language Models

The paper introduces RetinaGroundBench, a new benchmark for visual grounding of retinal OCT images, featuring 815 B-scans annotated with 4,537 bounding boxes for 13 biomarkers across 8 diseases. It evaluates 27 multimodal large language models (MLLMs) and finds that visual grounding remains largely unsolved, with the best model achieving only a 23.7% macro F1 score. To improve performance, the authors fine‑tune an 8B‑parameter MLLM, RetGrounder, using an OCT‑specific strategy that raises the grounding F1 to 33.9%, a 43% relative gain. whyItMatters":"The benchmark establishes a concrete reference for measuring progress in OCT diagnosis with multimodal large language models, highlighting the current limitations and guiding future improvements in visual grounding for clinical applications."