arXiv AI

A Stage-Wise Explainable Pipeline for Arteriolar-to-Venular Ratio Estimation and Retinopathy Screening

The paper introduces a five‑stage, explainable pipeline for estimating the arteriolar‑to‑venular diameter ratio (AVR) from fundus images and for screening retinopathy. Each stage—vessel and artery‑vein masking, optic‑disc localization, vessel‑calibre estimation via a minimal‑chord boundary walk, and AVR calculation from dominant branches—produces inspectable intermediate outputs, and a threshold‑based rule yields the screening decision. In an exploratory cohort of 30 high‑resolution fundus images, the method achieved 96.7% accuracy, an F1‑score of 0.968, and an ROC‑AUC of 0.978, with ablation studies highlighting the impact of vessel pairing, calibre measurement, and aggregation.

arXiv Computer Vision
Sep 1

retinalysis-vascx: An explainable software toolbox for the extraction of retinal vascular biomarkers

arXiv:2602.08580v4 Announce Type: replace-cross Abstract: Automatic extraction of retinal vascular biomarkers from color fundus images (CFI) is crucial for large-scale studies of the retinal vasculat...

By Jose D. Vargas Quiros, Michael J. Beyeler, Sofia Ortin Vela, EyeNED Reading Center, Sven Bergmann, Caroline C. W. Klaver, Bart Liefers, VascX Research Consortium
arXiv Computer Vision
Oct 27

Evidence-Guided Selection of Retinal Vessel Segmentation Pipelines: A Cross-Dataset Benchmark of Performance, Structure, Failure Modes, and Reproducibility

arXiv:2610.35357v1 Announce Type: new Abstract: Retinal vessel segmentation is widely used in retinal image analysis, yet model selection based only on aggregate overlap scores can overlook structura...

By Ruoyu Yan, Yuejia Liu, Shixin Xu, Xiaoyan Li, Xi Luo, Yuhui Deng, Huaxiong Huang
arXiv Computation and Language
Sep 7

Retinal OCTA Phenotyping with LLM Reporting for Alzheimer's Disease

The study introduces an explainable OCTA pipeline for Alzheimer’s disease phenotyping that combines vessel segmentation, layer‑specific biomarker extraction, and label‑free phenotyping with large language model (LLM) reporting. Using 117 images from 39 subjects, the segmentation models achieved high ROC‑AUC (0.916–0.970) and Dice scores (0.695–0.781), and six vascular biomarkers were used to create subject‑level profiles for exploratory clustering. LLMs (GPT, Gemini, Llama) produced measurement‑grounded reports evaluated for citation faithfulness and diagnostic caution, offering a transparent, non‑diagnostic link between retinal vascular data and Alzheimer’s research.

By Progga Paromita Dutta, Jeba Maliha, Md Rafiul Kabir
arXiv Computer Vision
Nov 9

A Novel Conditional Adversarial Diffusion Model for High-Fidelity OCT-to-OCT Image Translation and Precise Anti-VEGF Therapy Response Prediction in Diabetic Macular Edema

The paper introduces a conditional adversarial diffusion model that generates post‑treatment OCT images from baseline scans to predict anti‑VEGF therapy response in diabetic macular edema. Using 5‑fold cross‑validation on a US cohort (n=127) and external validation on an Iranian cohort (n=44), the model outperformed fourteen baseline and state‑of‑the‑art translation methods, achieving balanced accuracies of 85.7%–93.0% and 85.2%–95.3% at 10% and 20% central subfield thickness reduction thresholds. The framework aims to provide ophthalmologists with a noninvasive decision‑support tool for personalized therapy selection before treatment initiation.

By Reza Rasti, Armin Biglari, Sobhan Mohammadi Hafshejani, Alireza Dehghani, Michael J. Allingham, Sina Farsiu
arXiv Computer Vision
Aug 28

Automated 2D and 3D Segmentation of AMD and DME Lesions in OCT

This study presents four deep‑learning pipelines—two‑dimensional and three‑dimensional—for segmenting age‑related macular degeneration (AMD) and diabetic macular edema (DME) lesions in optical coherence tomography (OCT) images. The models achieve Dice scores between 0.76 and 0.82 and demonstrate strong volumetric and surface calibration (r_vol, r_surf ≥ 0.97) on an in‑domain validation set. Generalization was assessed on the OLIVES clinical cohort using proxy metrics such as biomarker AUROC, central subfield thickness correlation, and longitudinal concordance, showing that the predictions still track clinical biomarkers outside the training distribution, albeit with reduced strength.

By Lucia Sundberg, Zhihao Zhao, M. Ali Nasseri
arXiv Machine Learning
Aug 31

Explainable Diabetic Retinopathy Classification Using Vision Foundation Models

The paper presents an explainable diabetic retinopathy classification framework that leverages vision foundation models—DINOv2, CLIP, and Vision Transformer—combined with various transfer learning techniques such as full fine‑tuning, linear probing, and Low‑Rank Adaptation (LoRA). Using the ODIR dataset for internal validation and the APTOS dataset for external testing, DINOv2‑LoRA achieved the best internal AUROC (0.758) while DINOv2 and ViT full fine‑tuning reached the highest external AUROC (0.920). Explainability was assessed with Grad‑CAM and HiResCAM against expert‑annotated lesion masks from IDRiD, using Dice, IoU, and Pointing Game metrics, confirming that model attention aligns with clinically relevant retinal lesions.

By Abhishek Verma, Anila Krishna, Abhishek Gajanan Bankar, Juan Miguel Lopez Alcaraz
arXiv Computer Vision
Sep 14

An Ultra-Widefield Swept-Source OCTA Dataset and a Polar-Gated Mamba Network for Retinal Vessel Segmentation

arXiv:2609.12574v1 Announce Type: new Abstract: Ultra-widefield (UWF) swept-source optical coherence tomography angiography (SS-OCTA) enables large-area retinal vascular imaging, yet vessel segmentat...

By Yang Liu, Yibing Shen, Keming Zhao, Cenk Jiang, Zhenghang Qian, Zhicheng Du, Chen Xiong, Qidong Shao, Zijun Lin, Yunqi Hu, Jingjing Zhou, Lian Zhang, Peter E. Lobie, Peiwu Qin, Chengming Yang
arXiv Computer Vision
Oct 22

From Canon to Nikon: Camera Domain Shift and Potential Equity Implications in Retinal AI

The study examines how the choice of camera—Canon versus Nikon—affects image quality and AI performance in retinal screening for diabetic retinopathy. In a Brazilian cohort of 8,524 patients, Nikon images were more than twice as likely to be of inadequate quality compared with Canon, despite being cheaper. Using a frozen pretrained retinal foundation model, the authors evaluated 12 disease classification tasks across different resolutions and classifiers, finding that camera-related performance differences vary widely and are not consistently mitigated by higher resolution or classifier choice.

By Lisa Y. W. Tang