arXiv:2606. 16234v1 Announce Type: cross Abstract: Fundus fluorescein angiography (FFA) is critical for assessing retinal vascular abnormalities, but its acquisition is invasive and not always feasible.
By Tengfei Ma, Ruiqi Wu, Chenran Zhang, Ye Geng, Na Su, Xiangyuan Duanmu, Tao Zhou, Yi Zhou, Wen Fan
The paper introduces RetinaGroundBench, a new benchmark for visual grounding of retinal OCT images, featuring 815 B-scans annotated with 4,537 bounding boxes for 13 biomarkers across 8 diseases. It evaluates 27 multimodal large language models (MLLMs) and finds that visual grounding is largely unsolved, with the best model achieving only a macro F1 of 23.7%. The authors also present RetGrounder, an 8‑B parameter MLLM fine‑tuned for OCT, which raises grounding F1 to 33.9%, a 43% relative improvement.
By Ronald Fecso, Jos\'e Morano, Botond Fazekas, Paul Widmann-Sedlnitzky, Dorota Himel, Laetita Hinterhuber, Virginia Mares, Andreas Pollreisz, Hrvoje Bogunovi\'c
The paper introduces RetinaGroundBench, a new benchmark for visual grounding of retinal OCT images, featuring 815 B-scans annotated with 4,537 bounding boxes for 13 biomarkers across 8 diseases. It evaluates 27 multimodal large language models (MLLMs) and finds that visual grounding remains largely unsolved, with the best model achieving only a 23.7% macro F1 score. To improve performance, the authors fine‑tune an 8B‑parameter MLLM, RetGrounder, using an OCT‑specific strategy that raises the grounding F1 to 33.9%, a 43% relative gain.
whyItMatters":"The benchmark establishes a concrete reference for measuring progress in OCT diagnosis with multimodal large language models, highlighting the current limitations and guiding future improvements in visual grounding for clinical applications."
The paper presents an explainable diabetic retinopathy classification framework that leverages vision foundation models—DINOv2, CLIP, and Vision Transformer—combined with various transfer learning techniques such as full fine‑tuning, linear probing, and Low‑Rank Adaptation (LoRA). Using the ODIR dataset for internal validation and the APTOS dataset for external testing, DINOv2‑LoRA achieved the best internal AUROC (0.758) while DINOv2 and ViT full fine‑tuning reached the highest external AUROC (0.920). Explainability was assessed with Grad‑CAM and HiResCAM against expert‑annotated lesion masks from IDRiD, using Dice, IoU, and Pointing Game metrics, confirming that model attention aligns with clinically relevant retinal lesions.
By Abhishek Verma, Anila Krishna, Abhishek Gajanan Bankar, Juan Miguel Lopez Alcaraz
The paper introduces FOCUS, a cross‑dataset benchmark for retinal fundus models that evaluates vision‑only encoders, vision‑language dual encoders, and multimodal large language models across ten public datasets. It measures ranking performance, calibration, subgroup disparities, and image‑quality robustness for tasks such as diabetic retinopathy and glaucomatous optic neuropathy. Results show no single model family dominates, with vision‑only encoders ranking highest on average, while fine‑tuning improves in‑domain performance but varies in external transfer.
By David Restrepo, Chenwei Wu, Luis Filipe Nakayama, Miguel L. Martins, Stergios Christodoulidis, Maria Vakalopoulou, Enzo Ferrante
arXiv:2609.06699v1 Announce Type: cross
Abstract: Glaucoma is a progressive optic neuropathy characterized by irreversible damage to the optic nerve, making timely diagnosis critical to prevent perma...
By Abdullah Al Shafi, Nishat Sadaf Lira, Abrar Hasan, Kazi Saeed Alam, Swapnil Kundu Argha