arXiv:2602.08580v4 Announce Type: replace-cross
Abstract: Automatic extraction of retinal vascular biomarkers from color fundus images (CFI) is crucial for large-scale studies of the retinal vasculat...
By Jose D. Vargas Quiros, Michael J. Beyeler, Sofia Ortin Vela, EyeNED Reading Center, Sven Bergmann, Caroline C. W. Klaver, Bart Liefers, VascX Research Consortium
arXiv:2610.35357v1 Announce Type: new
Abstract: Retinal vessel segmentation is widely used in retinal image analysis, yet model selection based only on aggregate overlap scores can overlook structura...
By Ruoyu Yan, Yuejia Liu, Shixin Xu, Xiaoyan Li, Xi Luo, Yuhui Deng, Huaxiong Huang
arXiv:2608.24723v1 Announce Type: new
Abstract: Retinal fundus photography is widely used for screening and monitoring ocular diseases, but many modern classification pipelines rely on deep latent re...
By Xiaoyan Li, Shixin Xu, Arvind Gupta, Huaxiong Huang
Retinal fundus photography is widely used for screening and monitoring ocular diseases, but many modern classification pipelines rely on deep latent representations and provide limited interpretabilit...
The study introduces an explainable OCTA pipeline for Alzheimer’s disease phenotyping that combines vessel segmentation, layer‑specific biomarker extraction, and label‑free phenotyping with large language model (LLM) reporting. Using 117 images from 39 subjects, the segmentation models achieved high ROC‑AUC (0.916–0.970) and Dice scores (0.695–0.781), and six vascular biomarkers were used to create subject‑level profiles for exploratory clustering. LLMs (GPT, Gemini, Llama) produced measurement‑grounded reports evaluated for citation faithfulness and diagnostic caution, offering a transparent, non‑diagnostic link between retinal vascular data and Alzheimer’s research.
By Progga Paromita Dutta, Jeba Maliha, Md Rafiul Kabir
The paper introduces a conditional adversarial diffusion model that generates post‑treatment OCT images from baseline scans to predict anti‑VEGF therapy response in diabetic macular edema. Using 5‑fold cross‑validation on a US cohort (n=127) and external validation on an Iranian cohort (n=44), the model outperformed fourteen baseline and state‑of‑the‑art translation methods, achieving balanced accuracies of 85.7%–93.0% and 85.2%–95.3% at 10% and 20% central subfield thickness reduction thresholds. The framework aims to provide ophthalmologists with a noninvasive decision‑support tool for personalized therapy selection before treatment initiation.
By Reza Rasti, Armin Biglari, Sobhan Mohammadi Hafshejani, Alireza Dehghani, Michael J. Allingham, Sina Farsiu