arXiv:2607. 24519v2 Announce Type: replace Abstract: Pretrained EEG foundation models are proposed for clinical decoding, but whether reported gains transfer across populations or survive negative controls is unclear.
By Marzieh Zare
arXiv:2608.24727v1 Announce Type: cross
Abstract: EEG foundation models pretrained via self-supervised learning promise transferable representations, but their generalization remains limited, especia...
By Meghal Dani, Stefanie Liebe
arXiv:2607. 24519v1 Announce Type: cross Abstract: Pretrained EEG foundation models are increasingly proposed for clinical decoding, but their transfer across populations and robustness to negative controls remain unclear.
By Marzieh Zare
arXiv:2607. 24519v3 Announce Type: replace-cross Abstract: EEG foundation-model gains may depend on cohort, montage, or probe design.
By Marzieh Zare
arXiv:2606. 00074v1 Announce Type: cross Abstract: Reliable seizure prediction is a prerequisite for closed-loop neurostimulation therapy, yet existing methods rarely account for the variability in EEG signal quality encountered in real-world deployment, and the overwhelming majority adopt non-strict evaluation protocols that overestimate generalisation performance.
By Mufeng Chen, Qi Wu, Bingchao Huang, Xiwen Lai, Zekai Chen, Xinge Ouyang, Quansheng Ren
Pretrained EEG foundation models are increasingly proposed for clinical decoding, but their transfer across populations and robustness to negative controls remain unclear. We benchmark six models (LaBraM, EEGMamba, CBraMod, REVE, BENDR, and BIOT) on five clinical tasks across four datasets using frozen linear probes with leave-one-subject-out, subject-grouped, or explicitly identified recording-level splits.
EEG foundation models pretrained via self-supervised learning promise transferable representations, but their generalization remains limited, especially across diverse clinical datasets. Full fine-tun...
arXiv:2607. 21384v1 Announce Type: new Abstract: Electroencephalography (EEG) models used for epilepsy are often limited to specific datasets and tasks.
By Targol Bakhtiarvand, Jugal Kalita, Adham Atyabi
The study investigates whether Low‑Rank Adaptation (LoRA) can adapt three pretrained EEG foundation models—LaBraM‑base, REVE‑base, and REVE‑large—for binary left‑ vs. right‑hand motor imagery decoding in stroke patients. Using subject‑wise five‑fold cross‑validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 stroke dataset, LoRA significantly improved accuracy for LaBraM‑base (0.822) and REVE‑base (0.957) on the healthy cohort, but only REVE‑base LoRA achieved high performance (0.847±0.194) on stroke data, with a best mean accuracy of 0.952 in leave‑one‑subject‑out evaluation. The results demonstrate that healthy‑benchmark performance does not guarantee transfer to stroke EEG, highlighting the need for target‑domain adaptation and subject‑level assessment in rehabilitation BCIs.
By Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
arXiv:2606. 06647v1 Announce Type: new Abstract: Objective.
By Jun-You Lin, Ying Choon Wu, Tzyy-Ping Jung
The study evaluates self‑supervised pretraining for Prognostics and Health Management (PHM) across 47 public datasets, using a compact Transformer encoder trained with masked patch prediction. Transfer performance is highly task‑dependent: it dramatically improves fault‑classification on CWRU and HSG18 but offers no reliable benefit for remaining‑useful‑life estimation on CMAPSS. The authors also compare centralized versus simulated federated pretraining, finding that centralized training generally outperforms federated training under matched budgets, and that the intrinsic SSL loss does not reliably predict downstream performance.
By Jos\'e Sanz-Dur\'an, David Sol\'is-Mart\'in
arXiv:2609.35876v1 Announce Type: new
Abstract: Epileptic seizure forecasting aims to provide actionable warnings before seizure onset, yet patient-independent generalization and false-alarm control...
By Mason Dana, Khandaker Mamun Ahmed