arXiv:2606. 28164v1 Announce Type: cross Abstract: Echocardiography is the most widely used non-invasive cardiac imaging modality, providing essential information for cardiovascular diagnosis.
By Darya Taratynova, Ahmed Aly, Numan Saeed, Mohammad Yaqub
arXiv:2605.05447v2 Announce Type: replace
Abstract: We introduce EchoXFlow, a clinical echocardiography dataset with ultrasound in its native acquisition geometry. Existing public datasets offer limi...
By Elias Stenhede, Joanna Sulkowska, Eivind Bj{\o}rkan Orstad, Henrik Schirmer, Arian Ranjbar
arXiv:2512.09944v4 Announce Type: replace
Abstract: Echocardiography interpretation requires integrating multi-view temporal evidence with quantitative measurements and guideline-grounded reasoning,...
By Moein Heidari, Ali Mehrabian, Mohammad Amin Roohi, River Jiang, Wenjin Chen, David J. Foran, Jasmine Grewal, Ilker Hacihaliloglu
arXiv:2603. 08505v2 Announce Type: replace-cross Abstract: Electrocardiography (ECG) is a low-cost, widely used modality for diagnosing electrical abnormalities like atrial fibrillation by capturing the heart's electrical activity.
By Michelle Espranita Liman, \"Ozg\"un Turgut, Alexander M\"uller, Eimo Martens, Daniel Rueckert, Philip M\"uller
arXiv:2606. 17437v1 Announce Type: cross Abstract: Automated classification of standard echocardiographic views is crucial for efficient clinical workflow but faces three main challenges.
By Bo Gou, Jicheng Zhang, Jianlong Xiong, Tao He, Bentian Liu, Hai Wu, Yijiao Wang, Yu Zhang, Yujia Yang, Yun Dai, Jian Liu, Jie Wang
The paper introduces the first publicly available dataset for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography, comprising over 25,000 labeled videos generated through a novel data‑generation strategy that correlates clinical notes with echocardiographic videos. Using this dataset, the authors train a reproducible PLAX‑EF model that achieves a mean absolute error (MAE) of 6.86%, comparable to the clinical standard of apical four‑chamber (A4C) methods. They further show that combining PLAX and A4C predictions via simple late fusion reduces MAE to 6.37%, highlighting the benefit of multi‑view integration, and they release the dataset, models, and demos for community use.
arXiv:2606. 31099v1 Announce Type: cross Abstract: Recent years have seen substantial advances in radiology report generation (RRG), yet existing approaches predominantly adopt direct feature fusion when handling multi-view X-ray images.
By Yucheng Chen, Jinjing Zhu, Yang Yu, Yufei Shi, Hane Naghshbandi, Jinhua Liu, Angela S. Koh, Fang Fen, Kian Eng Ong, Si Yong Yeo
arXiv:2607. 01039v1 Announce Type: cross Abstract: Therapy-induced cardiotoxicity is the leading non-oncological cause of treatment interruption in breast cancer patients, yet early, automated risk stratification from routine cardiac imaging remains an unsolved problem.
By Grigorios Kalliatakis, Georgia Karanasiou, Georgios Manikis, Manolis Tsiknakis, Dimitrios Fotiadis, Dorothea Tsekoura, Kalliopi Keramida, Vasileios Bouratzis, Lampros Lakkas, Katerina Naka, Andri Papakonstantinou, Anastasia Constantinidou, Kostas Marias
BEAT-Net is a supervised biomimetic framework for ECG diagnosis that incorporates QRS-centered tokenization and a hierarchical architecture mirroring a cardiologist’s workflow. It processes heartbeat sequences through morphological, spatial, temporal, and transformer-based stages, achieving an AUC of 0.924 on large benchmarks while using only 0.7 million parameters. The model outperforms the 39.5‑million‑parameter HeartLang foundation model on morphological form classification and demonstrates superior cross‑dataset generalization with only 35% of the training data.
By Runze Ma, Haonan Lyu, Shunbo Jia, Qiang Yang, Muzi Xu, Jiaqi Zhang, Zihe Luo, Caizhi Liao
The paper introduces the first publicly available dataset of over 25,000 parasternal long‑axis (PLAX) echocardiography videos labeled for left ventricular ejection fraction (EF), created through a novel data‑generation strategy that links clinical notes to video data. Using this dataset, the authors train a reproducible PLAX‑based EF model that achieves a mean absolute error (MAE) of 6.86%, comparable to the clinical standard of apical four‑chamber (A4C) methods. They further show that simple late fusion of PLAX and A4C predictions reduces MAE to 6.37%, highlighting the benefit of multi‑view integration, and release the dataset, models, and demos publicly.
By Zhiyuan Gao, Dominic Yurk, Yaser S. Abu-Mostafa
arXiv:2608. 09053v1 Announce Type: cross Abstract: Cardiologists interpret electrocardiograms by localizing waveform components, measuring rhythm and interval patterns, and translating these structured observations into diagnostic evidence.
By Hongxiang Gao, He-yang Xu, Yuwen Li, Minghui Zhao, Zhipeng Cai, Xingyao Wang, Chenxi Yang, Jianqing Li, Chengyu Liu
Therapy-induced cardiotoxicity is the leading non-oncological cause of treatment interruption in breast cancer patients, yet early, automated risk stratification from routine cardiac imaging remains an unsolved problem. We present EchoRisk, the first curated, multicentre, longitudinal echocardiography dataset with explicit cardiotoxicity labels, released as the primary technical reference for the EchoRisk-MICCAI 2026 challenge.