arXiv:2607. 01039v1 Announce Type: cross Abstract: Therapy-induced cardiotoxicity is the leading non-oncological cause of treatment interruption in breast cancer patients, yet early, automated risk stratification from routine cardiac imaging remains an unsolved problem.
By Grigorios Kalliatakis, Georgia Karanasiou, Georgios Manikis, Manolis Tsiknakis, Dimitrios Fotiadis, Dorothea Tsekoura, Kalliopi Keramida, Vasileios Bouratzis, Lampros Lakkas, Katerina Naka, Andri Papakonstantinou, Anastasia Constantinidou, Kostas Marias
arXiv:2606. 17437v1 Announce Type: cross Abstract: Automated classification of standard echocardiographic views is crucial for efficient clinical workflow but faces three main challenges.
By Bo Gou, Jicheng Zhang, Jianlong Xiong, Tao He, Bentian Liu, Hai Wu, Yijiao Wang, Yu Zhang, Yujia Yang, Yun Dai, Jian Liu, Jie Wang
arXiv:2606. 00123v1 Announce Type: cross Abstract: Multimodal Large Language Models (MLLMs) have shown strong performance on public medical benchmarks, yet existing evaluations often remain weak proxies for clinical use, relying on isolated inputs and simplified recognition-style tasks.
By Zixian Su, Hongkai Zhang, Fan Gao, Encheng Su, Taiping Qu, Jingwei Guo, Nan Zhang, Hui Wang, Zhen Zhou, Kairui Bo, Yan Chen, Yue Ren, Shuai Li, Lei Xu, Henggui Zhang
The paper introduces the first publicly available dataset for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography, comprising over 25,000 labeled videos generated through a novel data‑generation strategy that correlates clinical notes with echocardiographic videos. Using this dataset, the authors train a reproducible PLAX‑EF model that achieves a mean absolute error (MAE) of 6.86%, comparable to the clinical standard of apical four‑chamber (A4C) methods. They further show that combining PLAX and A4C predictions via simple late fusion reduces MAE to 6.37%, highlighting the benefit of multi‑view integration, and they release the dataset, models, and demos for community use.
The paper introduces the first publicly available dataset of over 25,000 parasternal long‑axis (PLAX) echocardiography videos labeled for left ventricular ejection fraction (EF), created through a novel data‑generation strategy that links clinical notes to video data. Using this dataset, the authors train a reproducible PLAX‑based EF model that achieves a mean absolute error (MAE) of 6.86%, comparable to the clinical standard of apical four‑chamber (A4C) methods. They further show that simple late fusion of PLAX and A4C predictions reduces MAE to 6.37%, highlighting the benefit of multi‑view integration, and release the dataset, models, and demos publicly.
By Zhiyuan Gao, Dominic Yurk, Yaser S. Abu-Mostafa
arXiv:2609.26443v1 Announce Type: new
Abstract: Recent advances in Artificial Intelligence (AI)-powered Computer-Aided Diagnosis (CAD) systems have substantially improved breast cancer screening, dia...
By Farnoush Bayatmakou, Maryam Hosseini, Reza Taleei, Arash Mohammadi
arXiv:2606. 28164v1 Announce Type: cross Abstract: Echocardiography is the most widely used non-invasive cardiac imaging modality, providing essential information for cardiovascular diagnosis.
By Darya Taratynova, Ahmed Aly, Numan Saeed, Mohammad Yaqub
arXiv:2608.24688v1 Announce Type: new
Abstract: Precision oncology necessitates a longitudinal model of patient state that captures cancer evolution and treatment over time, integrating multimodal ob...
By Eugene Vorontsov, Yi Kan Wang, Alican Bozkurt, Adam Casson, Ludmila Tydlitatova, Michal Zelechowski, Ezra E. W. Cohen, Jyoti D. Patel, Max Banaszak, Caitlin McWilliams, Shane Colley, Kate Sasser, Ryan Fukushima, Eric Lefkofsky, Razik Yousfi, Siqi Liu
EchoAlign is a vision‑language foundation model for echocardiography that aligns each cardiac structure, video, and study with its corresponding report text, using a visibility matrix to restrict supervision to the views that actually depict each structure. Trained on 2.87 million videos and images from 159 clinical centers, it outperforms five public foundation models on 0.47 million test videos from ten unseen external datasets, achieving a mean AUROC of 0.890 for classification and a mean quadratic weighted kappa of 0.530 for severity grading. The model can detect findings, grade severity, estimate measurements, and segment cardiac structures across 62 clinical findings.
By Ahmed Aly, Darya Taratynova, Lotfi Abdelkrim Mecharbat, Roman A. Sandler, Joseph Z. Sokol, Joshua Penn, Klaus H. Maier-Hein, Numan Saeed, Mohammad Yaqub
arXiv:2610.05603v2 Announce Type: replace
Abstract: Echocardiography is the most widely used cardiac imaging modality, yet interpretation demands integrating visual evidence across global anatomy, lo...
By Sheng Cheng, Donnchadh M. O'Sullivan, Daniel J. Penny, Craig G. Rusin, Minh B. Nguyen, Devika Subramanian
arXiv:2608.30975v1 Announce Type: cross
Abstract: Cardiac magnetic resonance imaging (CMR) produces rich sequential data such as temporal cine videos and spatial LGE/mapping stacks, yet most deep lea...
By Athira J. Jacob, Puneet Sharma, Dorin Comaniciu, Daniel Rueckert
arXiv:2608.29246v1 Announce Type: cross
Abstract: Late gadolinium enhancement (LGE) cardiac magnetic resonance (MR) imaging is the modality of choice to assess myocardial infarction (MI) lesions. Now...
By Olivier Bernard, William A. Romero R., Cyprien Bouton, Celia Goujat, Hang Jung Ling, Pierre-Marc Jodoin, Fumin Guo, Calder Sheagren, Graham Wright, Abdul Qayyum, Moona Mazher, Steven A. Niederer, Hairui Wang, Xiaomei Wu, Franz Thaler, Gernot Plank, Martin Urschler, Ricardo M. Rosales, Esther Pueyo, Nicolas Duchateau, Frederic Cervenansky, Patrick Clarysse, Loic Belle, Thomas Bochaton, Nathan Mewton, Magalie Viallon, Pierre Croisille