The paper introduces CARDIAG, a multi‑center benchmark dataset for fine‑grained SYNTAX segmentation of coronary angiograms, featuring highly imbalanced multi‑class labels, catheter and stenosis masks, expert uncertainty maps, temporal frames, and spatial metadata. The authors conduct an extensive architectural sweep of 24 models—including CNNs, Vision Transformers, and State‑Space Models—using advanced metrics such as clDice, vessel diameter error, and uncertainty error‑detection. Their findings show that large‑kernel CNNs (ConvNeXt V2 with DeepLabV3+) outperform recent ViTs and SSMs, achieving a Dice score of 0.456, which improves to 0.479 with model ensembling, while also exploring out‑of‑distribution generalization through leave‑one‑center‑out cross‑validation.
By Dominik Bernard Lau, Jerzy Szyjut, Hubert Malinowski, Adam Brzeski, Tomasz Dziubich, Natalia Zieli\'nska, Tomasz Figatowski, Rados{\l}aw Targo\'nski
arXiv:2610.05603v2 Announce Type: replace
Abstract: Echocardiography is the most widely used cardiac imaging modality, yet interpretation demands integrating visual evidence across global anatomy, lo...
By Sheng Cheng, Donnchadh M. O'Sullivan, Daniel J. Penny, Craig G. Rusin, Minh B. Nguyen, Devika Subramanian
arXiv:2606. 28164v1 Announce Type: cross Abstract: Echocardiography is the most widely used non-invasive cardiac imaging modality, providing essential information for cardiovascular diagnosis.
By Darya Taratynova, Ahmed Aly, Numan Saeed, Mohammad Yaqub
arXiv:2609.08043v1 Announce Type: cross
Abstract: Deep learning has achieved state-of-the-art performance in echocardiographic video segmentation, with an increasing number of models incorporating te...
By Jiyoo Noh, Jonathan H. Chan
AudioFuse is a hybrid architecture that jointly learns from spectrograms and raw waveforms to classify phonocardiograms. It combines a wide-and-shallow Vision Transformer for spectral features with a shallow 1D CNN for temporal waveforms, reducing overfitting while capturing complementary information. On the PhysioNet 2016 dataset, AudioFuse achieves a state‑of‑the‑art ROC‑AUC of 0.8608 and shows superior robustness to domain shift on the PASCAL dataset, outperforming both spectrogram‑only and waveform‑only baselines.
By Md. Saiful Bari Siddiqui, Utsab Saha
arXiv:2607. 22139v1 Announce Type: cross Abstract: Accurate pixel-level classification of coronary angiograms is critical for cardiovascular disease assessment, yet the field lacks standardized evaluation protocols.
By Dominik Bernard Lau, Hubert Malinowski, Jerzy Szyjut, Adam Brzeski, Tomasz Dziubich, Rados{\l}aw Targo\'nski, Tomasz Figatowski, Natalia Zieli\'nska