Therapy-induced cardiotoxicity is the leading non-oncological cause of treatment interruption in breast cancer patients, yet early, automated risk stratification from routine cardiac imaging remains an unsolved problem. We present EchoRisk, the first curated, multicentre, longitudinal echocardiography dataset with explicit cardiotoxicity labels, released as the primary technical reference for the EchoRisk-MICCAI 2026 challenge.
arXiv:2606. 17437v1 Announce Type: cross Abstract: Automated classification of standard echocardiographic views is crucial for efficient clinical workflow but faces three main challenges.
By Bo Gou, Jicheng Zhang, Jianlong Xiong, Tao He, Bentian Liu, Hai Wu, Yijiao Wang, Yu Zhang, Yujia Yang, Yun Dai, Jian Liu, Jie Wang
arXiv:2606. 00123v1 Announce Type: cross Abstract: Multimodal Large Language Models (MLLMs) have shown strong performance on public medical benchmarks, yet existing evaluations often remain weak proxies for clinical use, relying on isolated inputs and simplified recognition-style tasks.
By Zixian Su, Hongkai Zhang, Fan Gao, Encheng Su, Taiping Qu, Jingwei Guo, Nan Zhang, Hui Wang, Zhen Zhou, Kairui Bo, Yan Chen, Yue Ren, Shuai Li, Lei Xu, Henggui Zhang
The paper introduces the first publicly available dataset for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography, comprising over 25,000 labeled videos generated through a novel data‑generation strategy that correlates clinical notes with echocardiographic videos. Using this dataset, the authors train a reproducible PLAX‑EF model that achieves a mean absolute error (MAE) of 6.86%, comparable to the clinical standard of apical four‑chamber (A4C) methods. They further show that combining PLAX and A4C predictions via simple late fusion reduces MAE to 6.37%, highlighting the benefit of multi‑view integration, and they release the dataset, models, and demos for community use.
The paper introduces the first publicly available dataset of over 25,000 parasternal long‑axis (PLAX) echocardiography videos labeled for left ventricular ejection fraction (EF), created through a novel data‑generation strategy that links clinical notes to video data. Using this dataset, the authors train a reproducible PLAX‑based EF model that achieves a mean absolute error (MAE) of 6.86%, comparable to the clinical standard of apical four‑chamber (A4C) methods. They further show that simple late fusion of PLAX and A4C predictions reduces MAE to 6.37%, highlighting the benefit of multi‑view integration, and release the dataset, models, and demos publicly.
By Zhiyuan Gao, Dominic Yurk, Yaser S. Abu-Mostafa
arXiv:2606. 28164v1 Announce Type: cross Abstract: Echocardiography is the most widely used non-invasive cardiac imaging modality, providing essential information for cardiovascular diagnosis.
By Darya Taratynova, Ahmed Aly, Numan Saeed, Mohammad Yaqub