EchoChat is a generative multimodal vision‑language model that performs comprehensive echocardiographic analysis, emulating a cardiologist’s cognitive workflow. Trained on 46,358 examinations, it achieves state‑of‑the‑art performance across 33 cardiac conditions, including 15 new ones, and outperforms existing foundation models in both recognition and quantification tasks. In a blinded reader study, reports co‑generated with EchoChat were rated higher in diagnostic accuracy and completeness, improving F1 score from 72.78% to 82.75%.
By Yi Qin, Marawan Elbatel, Shanshan Song, Taoran Huang, Jiarong Guo, Ningshu Li, Lehan Wang, Chenxu Zhao, Jiexin He, Machteld J. Boonstra, Stephan van der Zwaard, Marielle C. van de Veerdonk, Pere Lopez-Gutierrez, Lydia Dux-Santoy, Andrea Guala, Enrique Almar-Munoz, Sebastian Johannes Reinstadler, Radek Debiec, Yi-Hang Zhu, Huiyu Zhou, Adrian P Cheong, Yike Guo, Agnes Mayr, Karim Lekadir, Yong Jiang, Nilesh J. Samani, Dacheng Tao, Folkert W. Asselbergs, Hongwen Fei, Alex PW Lee, Xiaomeng Li
EchoTab is a representation learning framework for multi‑view echocardiography that uses measurement‑specific tokens as an intermediate representation between echo views and diagnosis. Each token attends to the views relevant to its measurement and is trained via tabular reconstruction to predict the measurement value, producing a factorized representation that encodes clinically meaningful structural and functional properties. Experiments on two datasets show that EchoTab improves diagnosis classification and that its learned attention aligns with cardiologists’ established measurement‑view relationships.
By Michelle Espranita Liman, Ioana Ionac, Alexander M\"uller, Eimo Martens, Daniel Rueckert, Philip M\"uller
arXiv:2606. 17437v1 Announce Type: cross Abstract: Automated classification of standard echocardiographic views is crucial for efficient clinical workflow but faces three main challenges.
By Bo Gou, Jicheng Zhang, Jianlong Xiong, Tao He, Bentian Liu, Hai Wu, Yijiao Wang, Yu Zhang, Yujia Yang, Yun Dai, Jian Liu, Jie Wang
Echocardiography assesses the structure and function of the heart. Cardiologists read each study across several standard views and report the findings visible in those views by cardiac structure. AI f...
EchoAlign is a vision‑language foundation model for echocardiography that aligns each cardiac structure, video, and study with its corresponding report text, using a visibility matrix to restrict supervision to the views that actually depict each structure. Trained on 2.87 million videos and images from 159 clinical centers, it outperforms five public foundation models on 0.47 million test videos from ten unseen external datasets, achieving a mean AUROC of 0.890 for classification and a mean quadratic weighted kappa of 0.530 for severity grading. The model can detect findings, grade severity, estimate measurements, and segment cardiac structures across 62 clinical findings.
By Ahmed Aly, Darya Taratynova, Lotfi Abdelkrim Mecharbat, Roman A. Sandler, Joseph Z. Sokol, Joshua Penn, Klaus H. Maier-Hein, Numan Saeed, Mohammad Yaqub
arXiv:2606. 00123v1 Announce Type: cross Abstract: Multimodal Large Language Models (MLLMs) have shown strong performance on public medical benchmarks, yet existing evaluations often remain weak proxies for clinical use, relying on isolated inputs and simplified recognition-style tasks.
By Zixian Su, Hongkai Zhang, Fan Gao, Encheng Su, Taiping Qu, Jingwei Guo, Nan Zhang, Hui Wang, Zhen Zhou, Kairui Bo, Yan Chen, Yue Ren, Shuai Li, Lei Xu, Henggui Zhang
arXiv:2603.22179v2 Announce Type: replace
Abstract: Cardiovascular disease remains the leading cause of global mortality, with progress hindered by human interpretation of complex cardiac tests. Curr...
By Jack W O'Sullivan, Mohammad Asadi, Lennart Elbe, Akshay Chaudhari, Tahoura Nedaee, Francois Haddad, Ivan Lopez, Fang Cao, Michael Salerno, Li Fe-Fei, Ehsan Adeli, Rima Arnaout, Euan A Ashley
arXiv:2609.38924v1 Announce Type: new
Abstract: Major adverse cardiovascular events (MACE) remain the leading cause of mortality worldwide. Opportunistic screening using routinely acquired clinical d...
By Jialu Pi, Yanan Ma, Weijie Chen, Owen Crystal, Shubham Trivedi, Stephen Xie, Anna Silverman, Matthew Stib, Chadi Ayoub, Reza Arsanjani, Imon Banerjee
The paper introduces the first publicly available dataset for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography, comprising over 25,000 labeled videos generated through a novel data‑generation strategy that correlates clinical notes with echocardiographic videos. Using this dataset, the authors train a reproducible PLAX‑EF model that achieves a mean absolute error (MAE) of 6.86%, comparable to the clinical standard of apical four‑chamber (A4C) methods. They further show that combining PLAX and A4C predictions via simple late fusion reduces MAE to 6.37%, highlighting the benefit of multi‑view integration, and they release the dataset, models, and demos for community use.
The paper introduces the first publicly available dataset of over 25,000 parasternal long‑axis (PLAX) echocardiography videos labeled for left ventricular ejection fraction (EF), created through a novel data‑generation strategy that links clinical notes to video data. Using this dataset, the authors train a reproducible PLAX‑based EF model that achieves a mean absolute error (MAE) of 6.86%, comparable to the clinical standard of apical four‑chamber (A4C) methods. They further show that simple late fusion of PLAX and A4C predictions reduces MAE to 6.37%, highlighting the benefit of multi‑view integration, and release the dataset, models, and demos publicly.
By Zhiyuan Gao, Dominic Yurk, Yaser S. Abu-Mostafa
arXiv:2606. 23888v1 Announce Type: cross Abstract: While Vision-Language Models (VLMs) show great promise in volumetric medical report generation, they frequently suffer from visual hallucinations and a lack of grounding in 3D CT data.
By Sijing Li, Zhongwei Qiu, Zhuoya Wang, Boxiang Yun, Zhenyu Yi, Jianwei Xu, Wenqiao Zhang, Yingda Xia, Ling Zhang
NV-Reason-CT is a generative vision‑language model designed for chest and abdominal CT analysis that preserves native 3D visual encoding and incorporates radiologist‑guided reasoning. The system couples a 3D vision transformer with a language model, feeding all visual tokens and their 3D coordinates directly into language decoding to maintain volumetric spatial information. Trained on a curated corpus of about 550,000 multimodal instruction examples, the model supports abnormality classification, report generation, and interactive reasoning, achieving strong performance on CT benchmarks and reducing expert interpretation time by 50%.
By Andriy Myronenko, Dong Yang, Yucheng Tang, Baris Turkbey, Benjamin Simon, Stephanie Harmon, Rikhil Makwana, Mariam Aboian, Sena Azamat, Ibrahim Ethem Hamamci, Sezgin Er, Bjoern Menze, Marc Edgar, Yufan He, Pengfei Guo, Daguang Xu