arXiv:2608.30835v1 Announce Type: cross
Abstract: Background and Objective: Quality control is a prerequisite for whole-slide image analysis, yet the benchmarks on which quality-control methods are c...
By Konstantinos Moutselos, Ilias Maglogiannis
Limited-angle digital breast tomosynthesis (DBT) reconstructs a volume from a few low-dose projections over a narrow arc. At a representative nine-view, $25^{\circ}$ protocol more than 98% of image space is unmeasured, so a learned prior must supply structure in the missing wedge.
arXiv:2609.15144v1 Announce Type: new
Abstract: Purpose: Paired pre- and post-operative photographs are the standard unit of evidence for plastic surgical outcomes, yet no objective metric verifies w...
By Derrick Lin, Samantha Rabinovich, Joclin Rabinovich, Kassra Garoosi, Sumun Khetpal, Evan Delanoy, Neel Bhardwaj, Jason Roostaeian
arXiv:2609.13237v1 Announce Type: cross
Abstract: Orthodontic report generation from intraoral data is normally cast as multimodal captioning, yet the released Bite2Text scan pairs are supplied alrea...
By Ajo Babu George, Govind Arun, Sidharth N Krishna, Uma Ranjan
arXiv:2608. 15090v1 Announce Type: cross Abstract: Studies of industrial visual inspection commonly report the area under the receiver operating characteristic curve (AUROC) and the overlap between anomaly maps and defect masks.
By Jie Deng
arXiv:2608. 12652v1 Announce Type: cross Abstract: Benchmark contamination is diagnosed today with n-gram overlap, with likelihood-based membership inference, or with canary strings, and each needs something usually unavailable: the training corpus, a well-chosen test statistic, or foresight at dataset release.
By Florian Braun
arXiv:2607. 13682v2 Announce Type: cross Abstract: Radiative Gaussian splatting reconstructs sparse-view CT fast and accurately, and recent work attaches per-Gaussian posteriors to yield per-voxel uncertainty maps.
By Chulin Zhao, Yiran Xu, Shu Liu
The study introduces the RSM framework, which includes the ARNAI artifact removal network, to enhance automated measurement of spinopelvic parameters on postoperative lumbar spine radiographs containing implants. Adding ARNAI to the Transformer-based FCBFormer model raised the mean Dice similarity coefficient from 0.814 to 0.870 and significantly reduced the mean L4–L5 segmental Cobb angle error from about 15.8° to 4.7°, a 70% improvement. The framework also improved intraclass correlation coefficients for key parameters, surpassing 0.70 for pelvic tilt, lumbar lordosis, and sacral slope.
By Sang-Jin Park, Jinyoung Choi, Seokwon Kim, Seungeon Song, Insu Park, Dougho Park, Taeyeon Kim, Youjin Lee, Donghoon Yang, Jaeman Cho, Joongwon Yang, Mansu Kim, Heumdai Kwon, Hong Gyu Baek, Dae Chul Cho, Injung Kim
arXiv:2608.28714v1 Announce Type: cross
Abstract: Objective: Deep learning accelerates brain MRI four- to tenfold, but models can erase lesions or synthesize false tissue - failures pixel-averaged me...
By Dat Tat Mai, Thai Viet Pham, Thu Nguyen Thi Dang, James Jin Kang
The paper argues that internal self-consistency checks cannot guarantee the accuracy of photogrammetric reconstructions, a limitation that is structural rather than a tuning issue. It introduces a track‑leakage‑free hold‑out protocol that withholds a deterministic subset of images and tests each against only 3D points supported by at least two retained images, ensuring no view is evaluated against the structure it helped create. Experiments on diverse datasets show that while the protocol is well‑posed, it saturates at a confidence score of 1.00 and fails to detect coherent distortion, missing large errors that can reach over 100 m.
whyItMatters":"The study highlights that hold‑out self‑validation scores, increasingly used as quality evidence for metric deliverables, may be misleading and cannot replace external survey validation."
By Behnam Asadi
arXiv:2608.31017v1 Announce Type: cross
Abstract: Ambient AI scribes draft clinical notes under the reassurance that a clinician signs every note. We audited three commercial AI scribes on the same 1...
By Sebastian Fox, Luke Markham, Ryan Lail, Michael Karotsieris
The study evaluates automatic tooth segmentation on panoramic radiographs using a large annotated corpus of 1,422 images and 42,142 tooth polygons. It finds that increasing input resolution improves boundary precision (mask mAP50‑95 rises from 0.656 to 0.717) while detection performance remains unchanged, and that architectural changes have minimal impact on in‑domain accuracy. Targeted interventions such as LoRA adaptation, promptable foundation models, and anatomical label assignment provide negligible gains, indicating that resolution and acquisition diversity should be prioritized over model novelty.
By Muhammad Rehan, Moaz Amjad, Syed Danial Ahmed, Mariam Adnan, Haider Ali