arXiv:2608. 07368v1 Announce Type: cross Abstract: Computed tomography (CT) remains the reference for 3D osseous morphometry in femoroacetabular impingement (FAI) but requires ionizing radiation and manual measurement.
By Jack Consolini, Eric A. Bogner, Meghan Sahr, Matthew F. Koff, Kevin M. Koch, Hollis G. Potter
arXiv:2610.33554v1 Announce Type: new
Abstract: Automated prostate lesion detection from diffusion-weighted MR imaging (DWI) conventionally relies on reconstructed images and does not fully use all a...
By Lukas T. Rotkopf, Marco Schlimbach, Kevin Kr\"{o}ninger, Stefan O. Schoenberg, Heinz-Peter Schlemmer, Jens Kleesiek, Moritz Rempe
arXiv:2608. 06311v1 Announce Type: cross Abstract: White matter hyperintensities (WMH), bright regions on Fluid-attenuated Inversion Recovery (FLAIR) scans are associated with cerebrovascular pathology and neurodegeneration.
By Zahra Khodakarami, Yue Li, Pulkit Khandelwal, John Detre, Sandhitsu Das, Christopher Brown, David Wolk, Paul Yushkevich
The study investigates whether 3D vertebra segmentation is essential for cervical spine fracture detection or if 2D projection-derived masks can suffice. Using a multi-stage pipeline—YOLOv8 for spine localization, DenseNet121‑Unet for 2D vertebra segmentation, and back‑projection to approximate 3D masks—the authors achieved vertebra‑level and patient‑level F1‑scores of 68.15 % and 82.28 %, with AUPRCs of 75.64 % and 92.00 % on the RSNA 2022 cohort. Replacing full 3D segmentation with projection‑derived masks resulted in negligible AUPRC changes, indicating that the simpler approach is a viable proxy for 3D segmentation in fracture recognition.
By Fabi Nahian Madhurja, Rusab Sarmun, Muhammad E. H. Chowdhury, Adam Mushtak, Israa Al-Hashimi, Sohaib Bassam Zoghoul
arXiv:2606. 03566v1 Announce Type: cross Abstract: Background: The lateral ventricle choroid plexus (LVCP) is gaining recognition as a key imaging biomarker for multiple sclerosis (MS) related to physical disability and neuroinflammation.
By Po-Jui Lu, Alessandro Cagol, Mario Ocampo-Pineda, Federico Spagnolo, Marina Mastantuono, Andreea-Alexandra Aldea, Jannis M\"uller, \"Ozg\"ur Yaldizli, Matthias Weigel, Lester Melie-Garcia, Roberta Magliozzi, Maria Pia Sormani, Ludwig Kappos, Jens Kuhle, Cristina Granziera
The study introduces ART‑Net, an anatomy‑aware residual attention network designed to refine four‑fold accelerated SENSE brain MRI. In a prospective paired study of 80 participants, ART‑Net achieved the highest peak signal‑to‑noise ratio and structural similarity index among evaluated methods, and it preserved anatomical fidelity with superior Dice coefficients for medial temporal and whole‑brain structures. Radiologist assessments also indicated improved gradient fidelity, regional contrast, and overall structural quality.
By Changjing Chai, Bin Huang, Libo Xu, Jian Zhou, Boyang Pan, Kristen W Yeom, Qiyong Gong, Nan-Jie Gong