Hugging Face Trending Papers

Exact and Calibrated Diffusion Reconstruction for Digital Breast Tomosynthesis

Limited-angle digital breast tomosynthesis (DBT) reconstructs a volume from a few low-dose projections over a narrow arc. At a representative nine-view, $25^{\circ}$ protocol more than 98% of image space is unmeasured, so a learned prior must supply structure in the missing wedge.

arXiv AI
Oct 5

Consecutive Posterior Fusion for Diffusive Recovery of Unobservable Image Structures

The paper introduces Consecutive Posterior Fusion Denoising Diffusion Null‑Space Models (CPF‑DDNM), an inference‑time method that fuses successive measurement‑aware estimates to better recover unobservable image structures in severely ill‑posed imaging inverse problems. CPF‑DDNM builds on DDNM’s range/null‑space decomposition, preserving measurement‑determined components while refining prior‑driven null‑space estimates. Experiments on sparse‑view CT, low‑dose CT, and medical image super‑resolution demonstrate consistent improvements over DDNM and competitive performance against other diffusion‑based inverse solvers.

By Elena Morotti, Davide Evangelista, Elena Loli Piccolomini
arXiv AI
Oct 31

EPC-RawDC: Equivariant Physics Constrained 3D Diffusion with Raw Data Consistency for CBCT to CT Image Synthesis

EPC‑RawDC is a 3‑D latent diffusion model that synthesises CT images from CBCT scans by enforcing two physics‑based constraints: a geometry‑equivariant projection loss and raw data consistency using scan‑specific CBCT projections. Trained on two clinical cohorts with different scanner geometries, the method achieved SSIM of 0.97 and improved PSNR and MAE over a baseline DDPM, reducing projection and equivariant errors by 55 % and 41 % respectively.

By Alzahra Altalib, Chunhui Li, Alessandro Perelli
arXiv AI
Sep 25

FB-GDM: Fully-Bayesian Guided Diffusion Models for High-Dimensional Linear Inverse Problems via Unsupervised Variational Inference

FB‑GDM is a fully‑Bayesian guided diffusion method that eliminates the need for task‑specific hyperparameter tuning in linear inverse problems. It derives a closed‑form conditional score from a Gaussian approximation of ΦGDM, treating two precision parameters as latent variables inferred via variational inference at each reverse step. Experiments on CelebA‑HQ show that FB‑GDM outperforms ΦGDM at its nominal setting, matches a ground‑truth‑calibrated oracle within 0.1 dB, and remains robust to changes in the forward operator, noise level, or image distribution without hallucinations.

By Gatien S\'eguy (SATIE), Thomas Rodet (SATIE)
arXiv AI
Jun 10

Deep Slice Interpolation for Reducing Through-Plane Anisotropy and Noise in Head CT

arXiv:2606. 09953v1 Announce Type: cross Abstract: Head computed tomography (CT) typically uses sub-millimeter in-plane resolution but 2-5 mm through-plane spacing, creating substantial anisotropy that degrades multiplanar reconstructions, volumetric measurements such as hematoma volume estimation, and downstream algorithms that assume near-isotropic voxels.

By Luis Cort\'es Ferre, Miguel A. Guti\'errez-Naranjo, Marcin Balcerzyk
arXiv AI
Sep 25

CATCH: Counterfactual Anatomical Tissue Inpainting with Conditional Haar Diffusion

CATCH is a conditional 3D diffusion model operating in an invertible Haar-wavelet domain designed to inpaint masked regions in T1‑weighted brain MRI with plausible, tumor‑free tissue while preserving observed anatomy. The model’s denoiser uses noisy target coefficients, voided‑image coefficients, and a signed mask, guided by tumor‑excluded wavelet reconstruction and a hole‑focused loss, and hard compositing ensures observed voxels remain unchanged. Experiments on BraTS data show that a weighted mixture of tumor‑derived, irregular‑blob, and ellipsoidal masks yields the best performance, achieving higher SSIM, PSNR, and lower MSE compared to fixed or random augmentation baselines.

By Simon Winther Albertsen, Hjalte Bjoernstrup, Said Djafar Said, Mostafa Mehdipour Ghazi
arXiv AI
Sep 17

Dose-Aware Cold Diffusion with Physics Consistency for Generalizable Low-Dose CT Reconstruction

The paper introduces Dose-Aware Cold Diffusion (DACD), a physics-consistent framework that treats radiation dose as a continuous latent variable in a cold diffusion process for low-dose CT reconstruction. DACD combines dose-aware perception, multi-scale structural priors, and dose-calibrated step allocation to guide denoising, and adds an iterative forward-backprojection correction to enforce projection-domain consistency. Experiments on Mayo-2020, Mayo-2016, and LoDoPaB-CT show DACD outperforms existing diffusion-based and physics-guided methods, especially at ultra-low doses, and generalizes robustly across continuous, unseen dose levels.

By Md Imam Ahasan, Guangchao Yang, A F M Abdun Noor, S M Hasan Mahmud, Md Mahfuzur Rahman