Diffusion posterior samplers reconstruct signals by combining a pretrained diffusion prior with a measurement likelihood specified by a forward model and a noise model. Calibration and reference data...
arXiv:2610.29102v1 Announce Type: new
Abstract: Diffusion posterior samplers reconstruct signals by combining a pretrained diffusion prior with a measurement likelihood specified by a forward model a...
By Wentao Shangguan, Vivek K Goyal
arXiv:2607. 13682v2 Announce Type: cross Abstract: Radiative Gaussian splatting reconstructs sparse-view CT fast and accurately, and recent work attaches per-Gaussian posteriors to yield per-voxel uncertainty maps.
By Chulin Zhao, Yiran Xu, Shu Liu
The paper introduces Consecutive Posterior Fusion Denoising Diffusion Null‑Space Models (CPF‑DDNM), an inference‑time method that fuses successive measurement‑aware estimates to better recover unobservable image structures in severely ill‑posed imaging inverse problems. CPF‑DDNM builds on DDNM’s range/null‑space decomposition, preserving measurement‑determined components while refining prior‑driven null‑space estimates. Experiments on sparse‑view CT, low‑dose CT, and medical image super‑resolution demonstrate consistent improvements over DDNM and competitive performance against other diffusion‑based inverse solvers.
By Elena Morotti, Davide Evangelista, Elena Loli Piccolomini
EPC‑RawDC is a 3‑D latent diffusion model that synthesises CT images from CBCT scans by enforcing two physics‑based constraints: a geometry‑equivariant projection loss and raw data consistency using scan‑specific CBCT projections. Trained on two clinical cohorts with different scanner geometries, the method achieved SSIM of 0.97 and improved PSNR and MAE over a baseline DDPM, reducing projection and equivariant errors by 55 % and 41 % respectively.
By Alzahra Altalib, Chunhui Li, Alessandro Perelli
FB‑GDM is a fully‑Bayesian guided diffusion method that eliminates the need for task‑specific hyperparameter tuning in linear inverse problems. It derives a closed‑form conditional score from a Gaussian approximation of ΦGDM, treating two precision parameters as latent variables inferred via variational inference at each reverse step. Experiments on CelebA‑HQ show that FB‑GDM outperforms ΦGDM at its nominal setting, matches a ground‑truth‑calibrated oracle within 0.1 dB, and remains robust to changes in the forward operator, noise level, or image distribution without hallucinations.
By Gatien S\'eguy (SATIE), Thomas Rodet (SATIE)