arXiv AI

ARNAI: Artifact Removal Network based on Autoencoding and Inpainting for Robust Spinal Image Segmentation and Measurement

The study introduces the RSM framework, which includes the ARNAI artifact removal network, to enhance automated measurement of spinopelvic parameters on postoperative lumbar spine radiographs containing implants. Adding ARNAI to the Transformer-based FCBFormer model raised the mean Dice similarity coefficient from 0.814 to 0.870 and significantly reduced the mean L4–L5 segmental Cobb angle error from about 15.8° to 4.7°, a 70% improvement. The framework also improved intraclass correlation coefficients for key parameters, surpassing 0.70 for pelvic tilt, lumbar lordosis, and sacral slope.

arXiv AI
Aug 10

Measurements Automatically Extracted from Zero Echo Time MRI Using Deep Learning Image Segmentation and Geometric Modeling Agree with Expert Manual Readings

arXiv:2608. 07368v1 Announce Type: cross Abstract: Computed tomography (CT) remains the reference for 3D osseous morphometry in femoroacetabular impingement (FAI) but requires ionizing radiation and manual measurement.

By Jack Consolini, Eric A. Bogner, Meghan Sahr, Matthew F. Koff, Kevin M. Koch, Hollis G. Potter
arXiv Computer Vision
Oct 27

End-to-end prostate lesion segmentation and detection from undersampled diffusion-weighted MRI

arXiv:2610.33554v1 Announce Type: new Abstract: Automated prostate lesion detection from diffusion-weighted MR imaging (DWI) conventionally relies on reconstructed images and does not fully use all a...

By Lukas T. Rotkopf, Marco Schlimbach, Kevin Kr\"{o}ninger, Stefan O. Schoenberg, Heinz-Peter Schlemmer, Jens Kleesiek, Moritz Rempe
arXiv AI
Nov 16

Tracing 3D Anatomy in 2D Strokes: Can Projection-Derived Masks Replace 3D Segmentation for Cervical Spine Fracture Recognition?

The study investigates whether 3D vertebra segmentation is essential for cervical spine fracture detection or if 2D projection-derived masks can suffice. Using a multi-stage pipeline—YOLOv8 for spine localization, DenseNet121‑Unet for 2D vertebra segmentation, and back‑projection to approximate 3D masks—the authors achieved vertebra‑level and patient‑level F1‑scores of 68.15 % and 82.28 %, with AUPRCs of 75.64 % and 92.00 % on the RSNA 2022 cohort. Replacing full 3D segmentation with projection‑derived masks resulted in negligible AUPRC changes, indicating that the simpler approach is a viable proxy for 3D segmentation in fracture recognition.

By Fabi Nahian Madhurja, Rusab Sarmun, Muhammad E. H. Chowdhury, Adam Mushtak, Israa Al-Hashimi, Sohaib Bassam Zoghoul
arXiv AI
Jun 3

Efficient Transformer-Based Localized Patch Sampling for Choroid Plexus Segmentation in Multiple Sclerosis

arXiv:2606. 03566v1 Announce Type: cross Abstract: Background: The lateral ventricle choroid plexus (LVCP) is gaining recognition as a key imaging biomarker for multiple sclerosis (MS) related to physical disability and neuroinflammation.

By Po-Jui Lu, Alessandro Cagol, Mario Ocampo-Pineda, Federico Spagnolo, Marina Mastantuono, Andreea-Alexandra Aldea, Jannis M\"uller, \"Ozg\"ur Yaldizli, Matthias Weigel, Lester Melie-Garcia, Roberta Magliozzi, Maria Pia Sormani, Ludwig Kappos, Jens Kuhle, Cristina Granziera
arXiv Computer Vision
Sep 22

Anatomically Faithful Artifact Suppression in SENSE Accelerated Brain MRI

The study introduces ART‑Net, an anatomy‑aware residual attention network designed to refine four‑fold accelerated SENSE brain MRI. In a prospective paired study of 80 participants, ART‑Net achieved the highest peak signal‑to‑noise ratio and structural similarity index among evaluated methods, and it preserved anatomical fidelity with superior Dice coefficients for medial temporal and whole‑brain structures. Radiologist assessments also indicated improved gradient fidelity, regional contrast, and overall structural quality.

By Changjing Chai, Bin Huang, Libo Xu, Jian Zhou, Boyang Pan, Kristen W Yeom, Qiyong Gong, Nan-Jie Gong
arXiv Computer Vision
Sep 16

Anatomy-Change-Aware Bidirectional Selective State-Space Memory for Clinically Deployed Thoracic Radiotherapy Auto-Contouring

The paper introduces DAMM‑Net++, a 2.5D neural network for thoracic organ‑at‑risk and target volume segmentation that tackles inter‑slice surface incoherence, small low‑contrast target failure, and lack of per‑case reliability signals. Its core is an anatomy‑change‑aware bidirectional selective state‑space memory that propagates context across axial slices, complemented by a boundary‑aware decoder and an uncertainty head for calibrated per‑voxel confidence. Evaluations on 2,146 patients, an external cohort, and a reader study show high Dice scores (0.955), low HD95 (3.78 mm), significant time savings (75‑80 %) for clinicians, and improved junior‑reader performance, with the system fully integrated into a clinical workflow.

By Galib Ahmed, Istiak Ahmed, Aritra Islam Saswato, Asib Mostakim Fony, Kazi Shahriar Sanjid, Md. Tanzim Hossain, Md. Anwarul Islam, Md. Nishan Khan, Md. Misbah Khan, Labiba Faiza Karim, Jobaer Rahman, S M Hasibul Hoque, Rahnuma Shahrin Rista, Kamruzzaman Rumman, Md Arifur Rahman, Syed Md. Akram Hussain, Mohammad Ashrafuzzaman Khan, M. Monir Uddin
arXiv AI
Sep 1

Extending TotalSegmentator: Predicting Patient and Acquisition Characteristics from CT and MR Images

arXiv:2608.29348v1 Announce Type: new Abstract: Background: Patient details and acquisition metadata are important for clinical decisions, image quality control, and automated research pipelines, but...

By Jakob Wasserthal, Joshy Cyriac, Michael Bach, Kimia Mozahheb Yousefi, Minh-Son To, M\'at\'e Sik, C\'edric H\'emon, Thomas Weikert, Martin Segeroth
arXiv Computer Vision
Oct 2

VoxelSynth3D: Interpretable Volumetric Image-Domain Metal Artifact Reduction with a Paired Synthetic CLINIC-Metal Benchmark

VoxelSynth3D is a training‑free 3D image‑domain framework that reduces metal artifacts in postoperative musculoskeletal CT by combining support masking, normalized tissue synthesis, deviation gating, and restricted edge refinement. The method preserves implant voxels while correcting surrounding tissue artifacts and was evaluated on a newly constructed Synthetic CLINIC‑Metal benchmark, showing a reduction in RMSE from 801.48 to 786.18 HU on 40 held‑out cases. Compared to a 3D Gaussian smoother, VoxelSynth3D achieved a 13.58 HU improvement and maintained clean-edge agreement beyond 5 mm from metal.

By Amritesh Banerjee, Abdul Basit, Renil Renji Joseph, Nouhaila Innan, Muhammad Shafique
arXiv AI
Nov 16

TotalSegmentator Aorta Report: Automated Aortic Diameter Measurement at 11 Standardized Landmarks on CT Images

The study presents TotalSegmentator, an open‑source, fully automated tool that measures aortic diameters at 11 standardized landmarks on CT images. In a retrospective single‑center cohort of 239 CT angiographies, the tool achieved a mean absolute error of 1.06 mm, with 86.6 % of measurements within 2 mm of a radiologist‑verified reference. Accuracy was slightly lower at the aortic root and in cases with mural thrombus, but overall performance was comparable to inter‑reader variability.

By Jakob Wasserthal, Daniel Hinck, Martin Segeroth, Joshy Cyriac, Denis Berdajs, Jules Miazza, Maurice Pradella