The study evaluates automatic tooth segmentation on panoramic radiographs using a large annotated corpus of 1,422 images and 42,142 tooth polygons. It finds that increasing input resolution improves boundary precision (mask mAP50‑95 rises from 0.656 to 0.717) while detection performance remains unchanged, and that architectural changes have minimal impact on in‑domain accuracy. Targeted interventions such as LoRA adaptation, promptable foundation models, and anatomical label assignment provide negligible gains, indicating that resolution and acquisition diversity should be prioritized over model novelty.
By Muhammad Rehan, Moaz Amjad, Syed Danial Ahmed, Mariam Adnan, Haider Ali
EviDent-CBCT is a framework that generates dental cone‑beam CT reports from limited clinical data by first extracting a discrete record of tooth‑level, global, and tooth‑IAC evidence using an anatomy‑aware network. The evidence is reconciled through a dental‑logic consistency projection before being rendered into a report by a deterministic renderer and an image‑blind language model. The system achieves higher evidence set‑F1 and logical‑F1 scores than baselines and ranked highly in the ODIN 2026 challenge, demonstrating the effectiveness of a discrete evidence record for auditable CBCT report generation.
By Ruiyang Hao, Zhi Qin Tan, Yulan He, Owen Addison, Yunpeng Li
arXiv:2609.13238v1 Announce Type: new
Abstract: Maxillofacial report generation from cone beam computed tomography is scored here by a composite objective placing 80% of its weight on a large languag...
By Ajo Babu George, Govind Arun, Sidharth N Krishna, Uma Ranjan
PeriaTrace is a three-stage framework that performs tooth-level diagnosis, generates visually grounded reports, and provides patient-friendly explanations and care recommendations from periapical radiographs. In internal testing on 12,877 images, it achieved high performance metrics (macro Dice 85.35%, BLEU-4 0.6504, F1 94.37% for tooth localization and FDI identification, grounding-tag F1 77.93%). External evaluations showed that senior endodontists found 91.16% and 84.52% of its reports suitable for use without major rewriting, and users preferred its plain-language explanations and visual cues.
By Zhenhuan Zhou, Yuchen Zhang, Jingbo Zhu, Shiqing Ma, Yanlin Wu, Tao Li
arXiv:2609.09801v1 Announce Type: cross
Abstract: Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed...
By Zhichun Jin, Zhicheng He, Hao Xu, Dongyang Li, Lin Wang, Hongliang Ren, Long Bai
Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement,...
arXiv:2606. 28628v1 Announce Type: cross Abstract: Localized generative editing needs localized evaluation: full-image identity metrics are structurally confounded under hard-composited edits.
By Mudit Agarwal, Amit D. Bhrany
Prototype-based networks provide inherently interpretable classification by linking predictions to learned exemplars, but their use in 3D point clouds and clinical surface-pair reasoning remains limited. We introduce ProtoPointNet, a prototype-based model for dental occlusion classification from registered upper--lower intraoral arch pairs.
arXiv:2609.15144v1 Announce Type: new
Abstract: Purpose: Paired pre- and post-operative photographs are the standard unit of evidence for plastic surgical outcomes, yet no objective metric verifies w...
By Derrick Lin, Samantha Rabinovich, Joclin Rabinovich, Kassra Garoosi, Sumun Khetpal, Evan Delanoy, Neel Bhardwaj, Jason Roostaeian
arXiv:2609.17800v1 Announce Type: new
Abstract: Vision-language models (VLMs) remain largely unreliable on panoramic dental radiographs and can rely on learned anatomical priors rather than evidence...
By Ahmed Rafid, Fariya Ahmed, Rumman Adib, Mehedi Ahamed, Ajwad Abrar, Tareque Mohmud Chowdhury
arXiv:2608.21913v1 Announce Type: new
Abstract: Completing dental records from cone-beam computed tomography (CBCT) is difficult when annotation is scarce and individual clinical fields are supported...
By Nhi Ngoc-Yen Nguyen, Thai Nguyen, Kiet Huynh Cao Tuan, Huy-Hieu Pham
The paper audits a prenatal ultrasound biometry pipeline that predicts head circumference (HC) while certifying a maximum error rate rather than magnitude. Using two pre‑registered splits of 999 HC18 images, the authors retrain the segmenter three times per split and calibrate a contour‑completeness threshold via exact Clopper–Pearson risk control. Although the certified risk bound (α = 0.10) remains intact, the pipeline still produces a large 271.3 mm error on a single image, and tightening the admissibility region to an anatomically defined range reduces worst‑case errors to about 11 mm while only modestly affecting coverage.
By Zhengshuai Yang, Linna Jiang, Changyun Li, Guihu Zhao