TransGHOST is a real‑time, synthesis‑free reconstruction system for ophthalmic microsurgery that restores instrument‑occluded regions by resampling recorded frames with geometric transforms. It operates in a safe, causal mode, providing per‑pixel confidence, provenance, and abstentions for unsupported pixels. Evaluated on a veterinary canine cataract surgery dataset, TransGHOST achieves high masked PSNR and SSIM with low latency, outperforming state‑of‑the‑art inpainting methods and demonstrating robust performance even when reference frames are occluded.
By Niran Nataraj, Maina Sogabe, Masamichi Yamashita, Norihiko Ito, Kenji Kawashima
arXiv:2606. 28628v1 Announce Type: cross Abstract: Localized generative editing needs localized evaluation: full-image identity metrics are structurally confounded under hard-composited edits.
By Mudit Agarwal, Amit D. Bhrany
Positive margins in head and neck oncologic surgery require mapping specimen-side pathology findings to the patient resection bed. This is challenging because pathologists identify the positive margin on slices of the resected, deformed specimen, while surgeons must relocate the corresponding site on the resection bed using only verbal descriptions and no visual guidance.
arXiv:2609.37648v1 Announce Type: new
Abstract: Preoperative liver-tumor assessment requires segmentation, physical-space measurement, visual evidence, and resection planning from the same three-dime...
By Binghong Qian, Xuanhe Liu, Yifan Xing, Wenjie Deng, Jian Wu, Haochao Ying
arXiv:2608.24671v1 Announce Type: new
Abstract: Referring surgical video segmentation requires segmenting a target instrument or tissue region across video frames according to a natural language expr...
By Jiaxin Wen, Ming Yin, Lu Liu, Zeyu Fu
The paper presents a clinically viable pipeline that uses routine intraoperative C‑arm fluoroscopy to derive per‑vertebra 6‑DoF poses, which are co‑registered to an RGB‑D camera via a multimodal fiducial array. This approach provides independent subsurface ground truth for validating markerless spinal tracking methods without adding radiation or altering standard surgical workflows. Ex vivo tests show an end‑to‑end accuracy of about 2 mm and 3.3°, and the framework is applied to evaluate two markerless registration strategies on real surgical data.
By Connor Daly, Salvatore Russo, Jinendra Ekanayake, Daniel S. Elson, Ferdinando Rodriguez y Baena
The paper introduces a 3D flow‑matching prior method for correcting rigid motion in head cone‑beam CT scans. It uses a geometry‑bridge that links motion‑corrupted and motion‑free FDK reconstructions through progressively reduced simulated motion, guided by analytic velocity targets from the forward projector’s geometry derivative. The approach integrates learned image updates, spline‑based pose estimation, conjugate‑gradient data consistency, and total‑variation regularization, achieving state‑of‑the‑art reconstruction quality (PSNR 37.1 dB) and motion accuracy (RPE 0.27 mm) on simulated scans of 30 patients.
By Sungho Yun, Seungryong Cho
arXiv:2505. 07687v4 Announce Type: replace-cross Abstract: Multi-modal medical image synthesis is pivotal for alleviating clinical data scarcity, yet existing methods fail to reconcile global anatomical consistency with high-fidelity local detail.
By Feng Yuan, Yifan Gao, Haoyue Li, Xin Gao
The paper introduces a counterfactual lesion erasure technique that trains a small medical vision‑language agent, MedScope‑4B, to report only what is actually visible in an image. By creating inpainted images that remove lesions, control edits of the same shape elsewhere, and unedited lesion‑free images, the authors define an evidence sensitivity gap (ESG) to measure a model’s reliance on visual evidence versus textual prompts. MedScope‑4B achieves a high ESG of 0.758 on internal cases, significantly outperforming frontier models while maintaining accuracy on real lesions, and demonstrates that training on erased and edited images yields an evidence‑gated behavior not seen in larger models.
By Bhaskar Gurram
Exemplar is a few‑shot segmentation method that combines a frozen DINOv3 backbone with a fixed bank of classical native‑resolution filter responses in a single lightweight head. Trained only from support masks, it achieves a mean foreground intersection‑over‑union of 0.782 across eleven biomedical imaging datasets, outperforming either component alone and surpassing five other few‑shot methods in 54 of 55 comparisons. With a single annotated mask, Exemplar reaches 0.703, higher than a from‑scratch nnU‑Net trained on the same mask, and while nnU‑Net eventually overtakes it with eight masks, it requires 16–77× longer to fit.
By Michal Pr\r{u}\v{s}ek, Adam Novoz\'amsk\'y, Filip \v{S}roubek
DART is a new RGB‑D pretraining method for surgical vision foundation models that incorporates pseudo‑labeled depth maps as a pixel‑space reconstruction target during training. By adding a depth reconstruction head to DINOv2’s masked iBOT framework, DART improves representation quality without affecting downstream RGB‑only fine‑tuning or inference. Across eight surgical benchmarks—including segmentation, depth estimation, and image‑level recognition—DART outperforms both natural‑image and in‑domain baselines, demonstrating that geometric pseudo‑labels can strengthen foundation model pretraining without extra labels or inference cost.
By John J. Han, Adam Schmidt, Muhammad Abdullah Jamal, Jie Ying Wu, Omid Mohareri
RefineRank introduces a lightweight module, RefineNet, that jointly refines bounding boxes and ranks them for surgical spatio‑temporal grounding. By combining frozen medical vision‑language features with proposals from a frozen open‑set detector, it predicts coordinate corrections and quality scores for each candidate box, selecting the best refined or original box. On MedVidBench, RefineRank achieves the highest reported STG mIoU of 0.421 and improves oracle bounds and overall mIoU in controlled evaluations.
By Linzhe Jiang, Jiayuan Huang, Changhao Zhang, Chunyang Jiang, Zhehua Mao, Mobarak I. Hoque