arXiv:2607. 10551v1 Announce Type: cross Abstract: Accurate geometric calibration is essential for fluoroscopy-guided spinal imaging, digitally reconstructed radiograph (DRR) generation, and 2D--3D vertebral registration.
By Lin Li, Chaochao Zhou, Benjamin Aubert, Junlin Guo, Junchao Zhu
arXiv:2609.24560v1 Announce Type: new
Abstract: Confocal Laser Endomicroscopy (CLE) provides real-time, cellular-resolution optical biopsy but has a narrow field of view, which image mosaicing can ex...
By Ahmed Aboelela, Johannes Barcsay, Jana Friedhof, Miguel Gon\c{c}alves, Alexander Hann, Katharina Breininger
arXiv:2610.07561v1 Announce Type: new
Abstract: Image-guided surgery (IGS) depends on accurate tracking of surgical instruments to provide real-time navigation relative to anatomical structures. Comm...
By George Sideris, Justin Cree, Andrew Stirling, Mamadou Ly, \'Etienne L\'eger, D. Louis Collins
The paper introduces PICO, an end-to-end trainable model for 6DoF surgical tool pose estimation that uses multi-task learning to predict segmentation, depth, and pose parameters. It incorporates two geometry-aware proxy tasks—a projection loss and a point-to-point loss—to enforce consistency in 2D and 3D spaces, improving accuracy and robustness. Evaluated on the SurgRIPE dataset, PICO achieves strong performance, ranking second in rotation accuracy and maintaining competitive translation results, especially under occlusion.
By Lucy Fothergill, Pietro Valdastri, Dominic Jones, Duygu Sarikaya
Positive margins in head and neck oncologic surgery require mapping specimen-side pathology findings to the patient resection bed. This is challenging because pathologists identify the positive margin on slices of the resected, deformed specimen, while surgeons must relocate the corresponding site on the resection bed using only verbal descriptions and no visual guidance.
Accurate execution of preoperative plans in corrective femoral osteotomies remains challenging. Current techniques are limited by variable accuracy, invasiveness, and radiation exposure, with free-hand methods and patient-specific instrumentation (PSI) often requiring >30 and >6 fluoroscopic images, respectively.
arXiv:2608. 07116v1 Announce Type: cross Abstract: Camera localization in bronchoscopy remains a challenging problem due to stringent accuracy requirements, real-time constraints, and limited training data.
By Lumin Chen, Qingyao Tian, Jinpeng Li, Haoyu Jiang, Huai Liao, Xinyan Huang, Hongbin Liu, Dong Yi
This scoping review examined 117 studies on video-based markerless motion capture, most published from 2024 onward and focused on healthy adults walking in laboratories. The studies identified five main pipeline architectures, but most reported only raw joint angles without biomechanical refinement, achieving sagittal lower‑limb agreement of about 5–6°, which falls short of clinical acceptability. Validation of out‑of‑plane kinematics, kinetics, and performance in older or pathological populations was rare, and emerging computer‑vision techniques such as foundation‑model mesh recovery and differentiable inverse kinematics were largely absent from validated work.
By Florian Delaplace (LAMHESS, CHU), Elodie Piche (LAMHESS), Fr\'ed\'eric Chorin (IUF, LAMHESS), Raphael Zory (IUF, LAMHESS)
arXiv:2607. 23343v1 Announce Type: cross Abstract: Intraoperative 2D/3D registration aligns preoperative CT volumes with intraoperative X-ray or fluoroscopic images and is essential for image-guided interventions.
By Minheng Chen, Youyong Kong
MV-dVRK is the first ex‑vivo surgical dataset that provides multiple exposure‑synchronized stereo viewpoints, accurate surface geometry, and ground‑truth camera poses for endoscopic images. The benchmark’s static subset offers dense SfM reference geometry validated against an industrial 3D scanner, while the dynamic sequences cover ten surgical tasks with increasing kinematic complexity and tissue deformation. Using MV‑dVRK, the authors systematically compare zero‑shot monocular, stereo, multi‑stereo, and multi‑view 3D reconstruction methods, finding that multi‑stereo reconstruction with two endoscopes yields the highest coverage, and that optimization‑based multi‑view methods outperform feed‑forward foundation models when a third viewpoint is added.
By Guido Caccianiga, Sergey Prokudin, Yutong Chen, Bernard Javot, Rachael L'Orsa, Omer Burak Alada\u{g}, Yarden Sharon, Jens Rolinger, Ivan Capobianco, Anton Deguet, Siyu Tang, Katherine J. Kuchenbecker
C3VDReg is a benchmark for local-to-local colonoscopic registration that uses the Colonoscopy 3D Video Dataset (C3VD) to generate 10,015 partial-to-partial point cloud pairs, with 2,088 held‑out test pairs. Each pair consists of a source point cloud from depth reprojection and a target point cloud from CT mesh raycasting, evaluated under a standardized protocol of 8,192 points per cloud and fixed pose conventions. Experiments show that high geometric overlap does not guarantee reliable pose recovery, revealing translation ambiguity along repetitive tubular anatomy as a key failure mode.
By Linzhe Jiang, Jiayuan Huang, Sophia Bano, Matthew J. Clarkson, Zhehua Mao, Mobarak I. Hoque