EUReCA is a geometry‑aware, feed‑forward model that reconstructs cone‑beam CT images from 8–100 projections without needing view‑specific retraining. It encodes each projection with a shared multiscale backbone, back‑projects features into 3‑D grids, aggregates variable views at fixed cost, and refines the volume using a global transformer and decoder. On simulated and real patient data, EUReCA outperforms existing feed‑forward and iterative methods, achieving high PSNR and superior performance across all tested view counts.
By Jiening Zhu, Chengzhu Zhang, Jason Fan, LiCheng Kuo, Weixing Cai, Xiuxiu He, Laura Cervino, Jean Moran, Xiang Li, Tianfang Li, Yabo Fu
The paper introduces a high‑resolution Rectified Flow Matching model trained on 256×256 chest CT images to serve as a generative prior for CT reconstruction. A two‑stage training strategy—initial strong anatomically informed augmentation followed by fine‑tuning—helps mitigate overfitting and improve structural fidelity. When evaluated on various CT inverse problems, Flow Matching‑based reconstruction methods outperform diffusion‑based algorithms in PSNR, SSIM, and perceptual quality while requiring fewer sampling steps.
By Davide Evangelista
arXiv:2606. 16212v1 Announce Type: cross Abstract: Sparse-view CT reduces radiation dose and scanning time by acquiring fewer projection views, but angular undersampling makes reconstruction severely ill-posed, causing streak artifacts, structural blurring, and loss of fine details.
By Jigang Duan, Jiayi Wang, Heran Wang, Ping Yang, Genwei Ma, Xing Zhao
arXiv:2605.20470v2 Announce Type: replace-cross
Abstract: Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noi...
By Alzahra Altalib, Chunhui Li, Haytham Ahmad Alewaidat, Khaled Z. Alawneh, Ahmad Awad Qandeel, Alessandro Perelli
arXiv:2608. 03430v1 Announce Type: cross Abstract: Four-dimensional cone beam CT (4D CBCT) is important for image-guided radiation therapy of thoracic cancers, but its use is limited by long scan times, causing high patient dose and motion/sparse-sampling artifacts.
By Ivo Herzig, Pascal Paysan, Daniel Barco, Marc Andr\'e Stadelmann, Frank-Peter Schilling, Igor Peterlik, Michal Walczak, Lijin Aryananda, Woo Sang Ahn, Rudolf Marcel F\"uchslin, Lukas Lichtensteiger
arXiv:2610.09579v1 Announce Type: new
Abstract: Trajectory optimisation for cone-beam computed tomography (CT) determines which information sparse-view scans acquire. Fixed candidate pools prevent of...
By Linda-Sophie Schneider, Simon Wittl, Gabriel Herl, Andreas Maier