arXiv Computer Vision

Geometry-bridge flow matching for blind rigid-motion correction in head cone-beam CT

The paper introduces a 3D flow‑matching prior method for correcting rigid motion in head cone‑beam CT scans. It uses a geometry‑bridge that links motion‑corrupted and motion‑free FDK reconstructions through progressively reduced simulated motion, guided by analytic velocity targets from the forward projector’s geometry derivative. The approach integrates learned image updates, spline‑based pose estimation, conjugate‑gradient data consistency, and total‑variation regularization, achieving state‑of‑the‑art reconstruction quality (PSNR 37.1 dB) and motion accuracy (RPE 0.27 mm) on simulated scans of 30 patients.

arXiv AI
Oct 31

EUReCA: End-to-End Unified CBCT Reconstruction Across Clinical Acquisitions

EUReCA is a geometry‑aware, feed‑forward model that reconstructs cone‑beam CT images from 8–100 projections without needing view‑specific retraining. It encodes each projection with a shared multiscale backbone, back‑projects features into 3‑D grids, aggregates variable views at fixed cost, and refines the volume using a global transformer and decoder. On simulated and real patient data, EUReCA outperforms existing feed‑forward and iterative methods, achieving high PSNR and superior performance across all tested view counts.

By Jiening Zhu, Chengzhu Zhang, Jason Fan, LiCheng Kuo, Weixing Cai, Xiuxiu He, Laura Cervino, Jean Moran, Xiang Li, Tianfang Li, Yabo Fu
arXiv Computer Vision
Aug 31

Physics-Guided Flow Matching for CT Image Reconstruction

The paper introduces a high‑resolution Rectified Flow Matching model trained on 256×256 chest CT images to serve as a generative prior for CT reconstruction. A two‑stage training strategy—initial strong anatomically informed augmentation followed by fine‑tuning—helps mitigate overfitting and improve structural fidelity. When evaluated on various CT inverse problems, Flow Matching‑based reconstruction methods outperform diffusion‑based algorithms in PSNR, SSIM, and perceptual quality while requiring fewer sampling steps.

By Davide Evangelista
arXiv AI
Jun 16

LUCID: Learned Undersampling-Adaptive Consistency-Guided Inference with Deterministic Flow Matching for Sparse-View CT Reconstruction

arXiv:2606. 16212v1 Announce Type: cross Abstract: Sparse-view CT reduces radiation dose and scanning time by acquiring fewer projection views, but angular undersampling makes reconstruction severely ill-posed, causing streak artifacts, structural blurring, and loss of fine details.

By Jigang Duan, Jiayi Wang, Heran Wang, Ping Yang, Genwei Ma, Xing Zhao
arXiv Machine Learning
Aug 5

Dual-domain U-Nets with embedded back projection operators for motion-resolved 4D CBCT reconstruction

arXiv:2608. 03430v1 Announce Type: cross Abstract: Four-dimensional cone beam CT (4D CBCT) is important for image-guided radiation therapy of thoracic cancers, but its use is limited by long scan times, causing high patient dose and motion/sparse-sampling artifacts.

By Ivo Herzig, Pascal Paysan, Daniel Barco, Marc Andr\'e Stadelmann, Frank-Peter Schilling, Igor Peterlik, Michal Walczak, Lijin Aryananda, Woo Sang Ahn, Rudolf Marcel F\"uchslin, Lukas Lichtensteiger
arXiv AI
Oct 31

EPC-RawDC: Equivariant Physics Constrained 3D Diffusion with Raw Data Consistency for CBCT to CT Image Synthesis

EPC‑RawDC is a 3‑D latent diffusion model that synthesises CT images from CBCT scans by enforcing two physics‑based constraints: a geometry‑equivariant projection loss and raw data consistency using scan‑specific CBCT projections. Trained on two clinical cohorts with different scanner geometries, the method achieved SSIM of 0.97 and improved PSNR and MAE over a baseline DDPM, reducing projection and equivariant errors by 55 % and 41 % respectively.

By Alzahra Altalib, Chunhui Li, Alessandro Perelli
arXiv AI
Sep 24

Field-of-View Extension in Dental Cone-Beam CT via Implicit Neural Representations and Diffusion Model-Based Refinement

The paper presents a three‑stage framework to extend the field of view in dental cone‑beam CT scans that are limited by truncated detector configurations. First, an implicit neural representation estimates missing projection data; second, an iterative reconstruction generates a secondary volumetric image with better anatomical consistency; third, a fast diffusion model refines the image for enhanced quality. Experiments show reduced truncation artifacts and improved reconstruction of structures beyond the original field of view.

By Susanne Schaub, Florentin Bieder, Matheus L. Oliveira, Yulan Wang, Buyanbileg Sodnom-ish, Dorothea Dagassan-Berndt, Michael M. Bornstein, Philippe C. Cattin