arXiv AI

Proof-Grounded Patient-Specific Clinical Explanations from Knowledge-Graph Reasoning

The paper presents the CKG Clinical Explanation Engine, a post‑processing layer that transforms patient inference states and disease knowledge from a frozen, training‑free clinical knowledge‑graph reasoner into typed facts, explicit rule traces, provenance‑linked conclusions, and policy‑licensed recommendations. Evaluation on six workbooks covering 11,289 patients and 33,867 patient‑disease traces achieved perfect scores on IG‑range validity, knowledge provenance, cross‑sheet numerical fidelity, and fact/report field presence, with 99.29% consistency between availability and representation. The system also identified observed zero‑activation and partial evidence instances, passed a 30‑patient end‑to‑end audit, and demonstrated that rule replay and a bounded validator could detect all single‑fault mutants, establishing structural and implementation auditability while noting that clinical correctness and utility remain unestablished.

arXiv AI
Aug 11

CliniCARE-Bench: Clinical Calibrated Audit of Medical Reasoning in EHR

arXiv:2608. 07796v1 Announce Type: new Abstract: Large language models perform strongly on medical knowledge benchmarks, but reliable clinical deployment requires agents to conduct defensible investigations over heterogeneous, longitudinal records: determining what evidence is needed, retrieving and reconciling structured and free-text data, grounding conclusions in verifiable evidence, and deferring cases that cannot be resolved reliably.

By Veronica Chatrath, Bryan Zhu, George Pu, Jingxuan Fan, Apaar Shanker, Varun Ursekar, Anahita Sharma, Jason Qin, Keqi Han, Soham Dinesh Tiwari, Soham Dan, Vijay Kalmath, Yuan Li, Daniel Yue Zhang, Chenguang Wang, Zainab Doctor, Zhijun Yin, Nigam H. Shah, Yuan Xue
arXiv Machine Learning
Oct 7

Cite What You Explore: Budget-Aware LLM Reasoning over Medical KGs with Verifiable Evidence

The paper introduces BAR, a Budget‑Aware LLM Reasoning framework that enhances post‑discharge risk prediction by integrating external medical knowledge graphs (KGs). BAR refines KGs into disease‑specific evidence graphs with support scores and provenance, then uses an LLM to plan, navigate, and verify evidence within a patient‑specific budget. Experiments on MIMIC‑III and MIMIC‑IV across eight diseases show BAR improves AUPRC by 3.4 points, raises citation precision from 59.8% to 77.9%, and uses only 62‑65% of the allotted budget.

By Chen Chen, Dongjie Wang, Mei Liu, Zijun Yao
arXiv AI
1d ago

Evidence sufficiency assessment enables cost-effective review allocation in on-premise clinical AI agents

The paper proposes a training‑free evidence sufficiency assessment for on‑premise clinical AI agents, using a 4B model to score evidence from five ordered levels and a three‑tier sequential triage protocol. By calibrating a nominal top‑50% threshold and applying a one‑sided 95% Wilson lower confidence bound, the system selects between single‑run, five‑run consistency, or full‑deferral tiers to meet a 95% clinical target. Experiments on MIRA‑v2, CDM, VivaBench, and an in‑hospital liver malignancy cohort show that the single‑run top‑50% tier achieves a 98.91% pass rate, matching five‑run consistency while saving ~80% compute, while the full‑deferral tier caps false‑certification rates between 0.00% and 3.50%.

By Yiwen Qiu, Che Sun, Shu Shen, Wentao Wang
Hugging Face Trending Papers
Oct 5

Auditable Clinical Timeline Reconstruction with Provenance-Aware Evidence Graphs

The study evaluates an auditable patient‑timeline reconstruction system that tracks provenance, records revisions, and refuses to answer when evidence is missing. Using a synthetic corpus of 1,000 patients and 3,353 notes, two provenance‑aware Evidence Graph operators reduced graph size by 33–37% while preserving all answers across 6,813 query points; a fixed‑window baseline failed to answer over half of the points. The system’s evidence‑gating mechanisms (BioClinicalBERT and a zero‑shot LLM) responded appropriately to evidence‑unavailable controls, but performance varied on marker‑free controls, with BERT maintaining high accuracy but the LLM’s coverage dropping sharply. "whyItMatters":"The results demonstrate that provenance‑aware evidence graphs can significantly reduce data complexity while maintaining answer integrity, highlighting a practical approach to building auditable clinical NLP systems."

arXiv Computation and Language
Nov 11

An evidence-traceable benchmark of clinical reasoning in large language models

The paper introduces Med Evidence Bench (MEB), a benchmark of 1,536 physician‑constructed items covering guideline knowledge, standardized clinical scenarios, and real‑world laboratory scenarios, each linked to a versioned source‑text span. Across ten large language models, the Evidence Trace Score (ETS) ranged from 0.975 to 0.997 for guideline knowledge, 0.292 to 0.658 for standardized scenarios, and 0.182 to 0.447 for real‑world scenarios, with varying rankings across levels. Automated grading on 1,296 criterion‑level judgments matched the majority vote of three physicians with a macro‑F1 of 0.930, though agreement was lower for evidence application.

By Zhiqun Zhao (Advanced Medical Research Institute and Key Laboratory for Experimental Teratology of the Ministry of Education, Cheeloo College of Medicine, Shandong University, Jinan, China), Xiaodong Yang (Department of Urology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China), Bruce Gu (Shandong Computer Science Center, National Supercomputer Center in Jinan, Jinan, China, Qilu University of Technology, Shandong Academy of Sciences, Jinan, China), Ming Li (Department of Rheumatology and Immunology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China), Yi Fu (Information Network Management Office, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China), Song Li (Department of Medical Oncology, Qilu Hospital, Shandong University, Jinan, China), Qi Mei (Department of Oncology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China), Zhi Liu (Department of Clinical Laboratory, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China), Kai Zhang (Department of Breast Surgery, General Surgery, Qilu Hospital, Shandong University, Jinan, China), Kexue Fu (Shandong Computer Science Center, National Supercomputer Center in Jinan, Jinan, China, Qilu University of Technology, Shandong Academy of Sciences, Jinan, China), Jing Wu (Department of Central Laboratory, Public Health Clinical Center Affiliated to Shandong University, Shandong University, Jinan, China), Xiaofei Lu (Department of Breast Surgery, The First Affiliated Hospital of Shandong First Medical University, Jinan, China), Yule Li (Advanced Medical Research Institute and Key Laboratory for Experimental Teratology of the Ministry of Education, Cheeloo College of Medicine, Shandong University, Jinan, China), Zheng Wang (Department of Urology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China), Haiquan Lu (Advanced Medical Research Institute and Key Laboratory for Experimental Teratology of the Ministry of Education, Cheeloo College of Medicine, Shandong University, Jinan, China), Xiaoming Wu (Shandong Computer Science Center, National Supercomputer Center in Jinan, Jinan, China, Qilu University of Technology, Shandong Academy of Sciences, Jinan, China)