The study audits a class‑imbalance benchmarking protocol for multimodal chest X‑ray and EHR prediction using 29,083 MIMIC‑CXR images from 10,479 patients. It finds that record‑level splits create leakage: a simple lookup table can match the best model, and when evaluated on unseen patients all models collapse to predicting every case positive. After correcting for patient‑separated evaluation and refined labels, no imbalance strategy improves macro F2 beyond 0.01, tuned tree ensembles offer no advantage over logistic regression, and EHR variables alone remain at an all‑positive baseline, while image embeddings and diagnostic history provide the strongest signals.
By Dang-Khoa Bui, Quang-Huy Tran, Minh-Khoi Nguyen-Bui, Duc-Tuan Ngo, Thanh-Trong Tran, Tuan-Khoi Nguyen, Hoang-Anh Ngo
arXiv:2610.13357v5 Announce Type: replace-cross
Abstract: Wearable electrocardiogram (ECG) recordings pass through multiple networks and systems before automated interpretation, leaving patient metad...
By Kuan-Yu Chen, Kuan-Chen Wang, Yu Tsao, Jian-Jiun Ding
ECGGuard is a deep watermarking framework that embeds metadata into single‑lead ECG signals without quantizing the waveform. It uses a fully convolutional generator, a detector that decodes frame‑by‑frame, and a frozen arrhythmia classifier during training to prevent diagnostic changes. The system achieves over 98% bit accuracy under time shifts and recovers a 16‑bit payload exactly in 99.95% of clean segments, with robust performance under deletions, packet loss, and unseen subjects.
By Kuan-Yu Chen, Kuan-Chen Wang, Yu Tsao, Jian-Jiun Ding
arXiv:2606. 22054v2 Announce Type: replace-cross Abstract: Detectors for GNSS radio-frequency impairments (jamming, spoofing, multipath) are usually reported with a single AUC measured on the distribution they were tuned on.
By Chakshu Baweja
arXiv:2607. 05009v1 Announce Type: cross Abstract: Complete digital 12-lead electrocardiograms (ECGs) are essential for AI-enabled cardiovascular assessment, yet many clinical ECG records, particularly those digitized from ECG images, remain incomplete because of short display formats, incomplete waveform digitization, lead loss, or signal corruption.
By Xiaocheng Fang, Haoyu Wang, Jieyi Cai, Qinghao Zhao, Jun Li, Shanwei Zhang, Guangkun Nie, Yujie Xiao, Shun Huang, Jiarui Jin, Hongmin Liu, Guodong Wang, Shuohua Chen, Liming Lin, Shouling Wu, Hongyan Li, Shenda Hong
BiMa-ECGSR reconstructs a full 12‑lead ECG from reduced lead sets using a bidirectional Mamba state‑space encoder–decoder, offering both regression (BiMa‑SR) and diffusion (DiBiMa‑SR) variants. Trained on PTB‑XL, the models achieve high Pearson correlations—up to 0.979 for I+II+V1+V4—outperforming a least‑squares linear filter across 18 configuration–cohort pairs. A 12‑lead classifier trained on real ECGs attains macro AUROC scores within 0.004 of real ECGs when using reconstructions from three or four leads, and the model processes a 10‑second record in 45.8 ms on a GPU.
By Ugo Lomoio, Pierangelo Veltri, Pietro Hiram Guzzi
arXiv:2608. 16147v1 Announce Type: new Abstract: Class-imbalance handling is routinely evaluated on a single benchmark dataset, and the resulting conclusions are reported as if they were properties of the method.
By Diyorbek Musaev
arXiv:2607. 03009v1 Announce Type: new Abstract: Background: Foundation models (FMs) trained on large-scale unlabeled physiological data have emerged as a promising paradigm for medical artificial intelligence.
By Beatrice Zanchi, Giuliana Monachino, Alvise Dei Rossi, Luigi Fiorillo, Georgia Sarquella-Brugada, Giulio Conte, Francesca Dalia Faraci
arXiv:2607. 24035v1 Announce Type: cross Abstract: Explainable AI (XAI) is used to assess whether artificial intelligence models rely on meaningful patterns, yet explanations that appear plausible for individual predictions may systematically misrepresent model behavior.
By Nils Gumpfer, Michael Guckert, Samuel Sossalla, Birgit A{\ss}mus, Jennifer Hannig
The study audited ten different classifiers—including linear, tree‑ensemble, neural, glass‑box, and tabular foundation models—on national health survey data to predict myocardial infarction. By systematically removing features that could cause target leakage, the authors found that all models’ AUROC scores collapsed into a narrow band, indicating that reported high accuracy in prior work was largely due to leakage rather than model sophistication. The glass‑box explainable boosting machine performed comparably to other models while being much faster, and the authors demonstrated that fairness, calibration, and uncertainty can be audited and repaired without sacrificing performance.
By Raad Bin Tareaf, Murad Al-Rajab, Samia Loucif, Samer Ellaham, Cedric Schmitz
arXiv:2607. 23412v1 Announce Type: new Abstract: Electrocardiograms (ECGs) are widely used for cardiovascular risk prediction, yet models often fail to transfer across hospitals because of protocol, population, and measurement differences.
By Jie Lin, Weijie Sun, Sunil V. Kalmady, Anita Khalafbeigi, Abram Hindle, Padma Kaul, Russell Greiner
arXiv:2607. 13075v1 Announce Type: cross Abstract: Context can change whether a request is harmful without changing its topic or surface form.
By Dominik Schwarz