arXiv:2608. 00058v1 Announce Type: cross Abstract: Accurate measurement of ECG intervals, including PR, QRS duration, and QT/QTc, is central to cardiac diagnosis, yet the published ECG delineation literature evaluates performance almost exclusively as fiducial-point timing errors on small curated databases, rather than as clinical interval accuracy on large unselected cohorts.
By Farhan Adam Mukadam, Harshit Mishra, Nachiket Makwana, Pradyot Tiwari, Subramani Kandasamy, KVS Hari
arXiv:2605.25446v2 Announce Type: replace
Abstract: Routine electrocardiogram (ECG) reports offer scalable supervision for cardiovascular representation learning. In this retrospective study, we pret...
By Ziqing Yu, Yuhui Tao, Jiayu Huo, Lei Pan, Zilong Xiao, Juecheng Chen, Xiao Li, Jianxuan Li, You Zhou, Zhixing Li, Cong Wang, Beijian Zhang, Chen Chen, Hongyang Lu, Konstantinos Patlatzoglou, Daniel B. Kramer, Jonathan W. Waks, Yangang Su, Fu Siong Ng, Shuo Wang, Yixiu Liang, Junbo Ge
arXiv:2607. 23406v1 Announce Type: cross Abstract: Continuous cuffless blood pressure (BP) monitoring is essential for connected health systems and wearable devices, enabling early detection, longitudinal tracking, and personalized management of cardiovascular disease.
By Bo Wu, Haoling Wang, Zhuodiao Kuang, Kateryna Shapovalenko
arXiv:2610.28507v1 Announce Type: cross
Abstract: Laboratory measurements are essential for clinical decision making but typically require invasive blood sampling. Recent research suggests that ECG r...
By Walentin Palanchuk
arXiv:2607. 27404v1 Announce Type: new Abstract: Existing benchmarks for electrocardiogram foundation models primarily evaluate downstream predictive performance, providing limited insight into whether their internal representations can be faithfully decomposed, clinically interpreted, or reproduced across independent analyses.
By Yixuan Duan, Wei Qiu
BiMa-ECGSR reconstructs a full 12‑lead ECG from reduced lead sets using a bidirectional Mamba state‑space encoder–decoder, offering both regression (BiMa‑SR) and diffusion (DiBiMa‑SR) variants. Trained on PTB‑XL, the models achieve high Pearson correlations—up to 0.979 for I+II+V1+V4—outperforming a least‑squares linear filter across 18 configuration–cohort pairs. A 12‑lead classifier trained on real ECGs attains macro AUROC scores within 0.004 of real ECGs when using reconstructions from three or four leads, and the model processes a 10‑second record in 45.8 ms on a GPU.
By Ugo Lomoio, Pierangelo Veltri, Pietro Hiram Guzzi